Title Page

  • Permit to use ladders/stepladders

  • Contract name

  • Contract no.

  • Contractor name

  • Issued by (Osborne site manager)

  • Description of task

  • Issued to (name)

  • Select date

  • Location

  • Items to be checked

  • 1 (a) Can the need to access /work at height be avoided? If no, see 1 (b)

  • Reason

  • Action

  • 1 (b) Can alternative methods be employed? If no, see qn2

  • Reason

  • Action

  • 2 (a) Can a suitable working platform be provided? I.e (tick) If no, see qn3

  • Podium type tower with handrails

  • Mobile tower with x2 handrails & toe boards

  • Scaffold at least 600mm wide with x2 handrails & toe boards

  • Birdcage scaffold

  • MEWP

  • Note. Only trained persons to erect scaffolds/operate MEWP'S/erect towers

  • Reason

  • Action

  • 2 (b) Can suitable access be provided - I. E (tick) If no, see qn3

  • Internal access via ramp/stair/lift

  • External access via an existing fire escape stair

  • External access by passenger hoist

  • External access by 'Haki' type stair

  • Note. Seek permission to use lifts & fire escapes from building owners. Only trained persons to operate passenger hoist

  • Reason

  • Action

  • 3. A step ladder/ladder is suitable for use on site, but only if a suitable working platform/access as identified above cannot be provided

  • 3 (a) Step ladder - provide a suitable stepladder for use on site - I. E the stepladder must be (tick)

  • Class 1 & of suitable size

  • Erected on a smooth, even, nonslip surface

  • Able to be used without overreaching

  • Note. Never work from the top third of a stepladder

  • Action

  • Reason

  • 3 (b) Pole/extension ladder - provide a suitable pole/extending ladder for use on site - I. E it must be (tick)

  • Class 1 industrial, correct length, unpainted & free of defects

  • Placed at an angle of 1:4

  • Tied from the top of the ladder to a suitable fixing point, OR

  • Fixed at the bottom in a manner to prevent sideways movement, OR

  • Provided with a person to foot the ladder throughout

  • Able to be used without overreaching

  • Note. Ladders are not work platforms

  • Action

  • Reason

  • ** where it is not reasonably practicable to implement the first hierarchy measure, pass to the next giving reasons for unsuitability.

  • This Permit To Work Is Valid For The Date Of Issue Only

  • Returned: (date/time)

  • Confirm Return (site manager signed)

  • KEEP PERMIT ON SITE TO BE RETURNED TO GROUP SAFELY UPON CONTRACT COMPLETION

  • FRM/WAH/001 Rev 2 May 2014

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.