Information
-
The version control will be maintained by the SHEQ team and is controlled via the Safety Equipment Inspections Document 2073838157-15.
-
Maximo number
-
Bin location
-
Model
-
Impeller number /diameter
-
Serial Number
-
Recommended Summary
-
Select date
The version control will be maintained by the SHEQ team and is controlled via the Safety Equipment Inspections Document 2073838157-15.
Visual
-
1 : Inspect for damaged and / or missing power and control cables
-
Observation / Measurement
-
2: Inspect external surface for corrosion ( Records level - Nil , slight , moderate or severe )
-
Observation / Measurement
-
3: Inspect pump for mechanical damage or missing components
-
Lifting bridle
-
Chains
-
Shackles
Mechanical seals
-
4: Extract all water from bottom of oil chamber. Record volume ( C Pumps )
-
Observation / Measurement
-
5: Extract all water from bottom of stater housing. Record volume ( N pumps )
-
Observation / Measurement
-
6: Seal chamber pressure test , 100kpa / 5 minutes
-
Observation / Measurement
Electrical tests
-
8: Megger test windings and record wire No's
-
Observation / Measurement Phase 1
-
Observation / Measurement Phase 2
-
Observation / Measurement Phase 3
-
9: Measure Thermistor resistance and record wire No's ( C pumps )
-
Observation / Measurement
-
10: Measure Thermal contacts resistance and record wire No's ( C pumps )
-
Observation / Measurement
-
11 : Measure tritronics contacts +FLS10 resistance and record wire No's ( C pumps )
-
Observation / Measurement
-
12: Measure Thermal contacts + FLS10 resistance and record wire No's ( N pumps )
-
Observation / Measurement
Impeller
-
13 : Remove any foreign objects from impeller
-
Observation / Measurement
-
14 : Inspect impeller and pump case for damage and wear , check wear ring clearance and record
-
Observation / Measurement
-
15: Check impeller can be rotated by hand
-
Observation / Measurement
Test Run
-
16: Connect pump to power supply and operate at no load. Record running currents
-
Observation / Measurement
-
17: Record abnormal noise and vibration.
-
Observation / Measurement
Completion
-
Comments
-
Fit for service
-
Sign Here