Title Page
-
Name of the insured (what entity will be on the policy)
-
Trading as:
-
Location address:
-
Broker Name
-
Broker Email Address
-
Name and role of person conferred with on site:
-
Mobile number of person conferred with on site:
-
Email of person conferred with on site:
-
What is the status of the survey?
-
Time and date of survey
-
Overview of the occupation
-
Survey allocated to / Report prepared by:
-
Date of survey booking:
-
Policy Type:
-
Policy number:
-
Allocated to which Underwriter
- Alice Bullions
- Allen Pearson
- Brad Filtz
- Carla Clarke
- Joanne Archer
- Joelle Carter
- Jonathan Hyde
- Julian Carion
- Luke Ransom
- Madiko Kamocha
- Tony Tahche
-
Policy Values:
- Building:
- Contents:
- Stock:
- Removal of Debris:
- Gross Profit:
- Indemnity Period:
- Additional Increase Cost of Working
- Claims Costs
- Theft:
- Money:
- Equipment Breakdown
- Public & Products Liability
- Flood cover
-
Buildings:
-
Contents / Plant:
-
Stock:
-
Removal of Debris:
-
Insurable Gross Profit:
-
Indemnity Period (months):
-
Additional Increased Cost of Working:
-
Claims Costs:
-
Theft:
-
Money:
-
Equipment Breakdown Item Limit
-
Number of Items:
-
Public & Products Liability:
-
ANZSIC Code Description / Occupation (as per Policy)
-
ANZSIC Property Hazard Index (as per Policy):
-
Is the ANZSIC Code Description accurate?
-
What is the issue with the occupation desciption?
-
Is the Construction and Protection information supplied accurate?
-
Discrepancies between the Construction and Protection information supplied and what was identified during the virtual survey relate to:
- Year of Construction
- Floor
- Wall
- Roof
- Number of Storeys
- Asbestos
- Aluminium Composite Panel
- Insulated Panels
- Water Supply
- Fire Extinguishers
- Fire Blanket
- Sprinklers
- Monitored Smoke Detection System
- Hose Reel
- No Fire Protection
- Other
-
Year of Construction should be:
-
Floor construction should be changed to:
-
Wall construction should be changed to:
-
Roof construction should be changed to:
-
Number of Stories construction should be changed to:
-
Asbestos construction should be changed to:
- Nil
- <1%
- ≥1% to <5%
- ≥5 to <20%
- ≥20% to <30%
- ≥30% to <50%
- ≥50%
-
Aluminium Compostite Panel / Cladding construction should be changed to:
- Nil
- <1%
- ≥1% to <5%
- ≥5 to <20%
- ≥20% to <30%
- ≥30% to <50%
- ≥50%
-
Insulated Panel construction should be changed to:
- Nil
- <1%
- ≥1% to <5%
- ≥5 to <20%
- ≥20% to <30%
- ≥30% to <50%
- ≥50%
-
Water Supply should be changed to:
-
Fire Extinguisher protection should be changed to:
-
Fire blanket protection should be changed to:
-
Sprinkler protection should be changed to:
-
Monitored Smoke Detection protection should be changed to:
- Yes
- No
- Not remotely monitored
- Monitored to security company
- Monitored to Fire Brigade
-
Hore Reel protection should be changed to:
-
No Fire Protection protection shoud be changed to:
-
Other, should include the following details:
Construction
-
Building name / identifier
-
Building Type:
- Free Standing - Well detached
- Free Standing - Abutting / close proximity
- Attached
- Terrace Style
- Unit / tenancy within a multi-tenanted complex
- Shop / tenancy within a mall / arcade / shopping complex
- Other (add details in Note)
-
External Walls:
- If mixed types, select each with approximate percentage of each show in Note below:
- Brick
- Brick veneer / masonry on a timber frame
- Masonry - concrete block / stone
- Reinforced Concrete
- Concrete panels on protected steel frame
- Precast concrete panels on steel frame
- Tilt-up concrete panel
- Concrete / masonry dado wall with sheet metal on metal frame above
- Concrete / masonry dado wall with sandwich panel above
- Glass curtain wall on metal frame
- Sheet metal cladding on a metal frame
- Sheet metal cladding on a timber and metal frame
- Sheet metal cladding on a timber frame
- Fibrous cement sheet / panels (post 1985) on a metal frame
- Fibrous cement sheet / panels (post 1985) on a timber and metal frame
- Fibrous cement sheet / panels (post 1985) on a timber frame
- Asbestos cement sheet (pre 1985) on a metal frame
- Asbestos cement sheet (pre 1985) on a timber and metal frame
- Asbestos cement sheet (pre 1985) on a timber frame
- Aluminium Composite Panel - solid
- Aluminium Composite Panel - combustible core
- Aluminium Composite Panel - non-combustible core
- Sandwich Panel - combustible core (EPS, Fire retardant EPS, PU, etc)
- Sandwich Panel - FM Approved core (PIR, Xflam)
- Sandwich Panel - non-combustible core (mineral fibre, Rockwool, etc)
- Plastic / vinyl / fibreglass cladding
- Timber on metal frame
- Timber on metal and timber frame
- Timber on timber frame
- Part open sided
- Open sided / no walls
- Could not be determined
- Other construction, as detailed in Note below
-
Roof:
- If mixed types, select each with approximate percentage of each show in Note below:
- Reinforced concrete
- Reinforced concrete with sheet metal cover
- Reinforced concrete with combustible cover
- Sheet metal cladding on a metal frame
- Sheet metal cladding on a timber and metal frame
- Sheet metal cladding on a timber frame
- Tiles (clay, concrete) / slate shingles on a metal frame
- Tiles (clay, concrete) / slate shingles on a timber and metal frame
- Tiles (clay, concrete) / slate shingles on a timber frame
- Asbestos cement sheet (pre 1985) on a metal frame
- Asbestos cement sheet (pre 1985) on a timber and metal frame
- Asbestos cement sheet (pre 1985) on a timber frame
- Sandwich Panel - combustible core (EPS, Fire retardant EPS, PU, etc)
- Sandwich Panel - FM Approved core (PIR, Xflam)
- Sandwich Panel - non-combustible core (mineral fibre, Rockwool, etc)
- Glass on a metal frame
- Plastic / fibreglass cladding
- Timber panels / shingles on metal frame
- Timber panels / shingles on metal and timber frame
- Timber panels / shingles on timber frame
- Rubber / Malthoid / bitumen on timber substructure
- Could not be determined
- Other construction, as detailed in Note below
-
Floors:
- If mixed types, select each with approximate percentage of each show in Note below:
- Reinforced concrete
- Concrete with combustible wearing surface (eg parquetry)
- Concrete small part timber (<20% combustible)
- Concrete part timber (Between 20% and 50% combustible)
- Timber small part concrete (>50% combustible)
- Pavers / brick on non-combustible sub-strata
- Earth
- Tiles (stone / clay / porcelain) on non-combustible sub-strata
- Tiles (stone / clay / porcelain) on combustible sub-strata
- Metal (plate / mesh) on metal frame
- Metal (plate / mesh) on timber frame
- Timber on metal frame
- Timber on timber frame
- Bitumen / asphalt
- Could not be determined
- Other, as detailed in Note below
-
Number of levels ground and above:
- 1
- 1 plus small mezzanine
- 1 part 2
- 1 part 3
- 2
- 2 part 1
- 2 part 3
- 3
- 3 part 1
- 3 part 2
- 3 part 4
- 4
- 4 part 5
- 5 to 8
- 9 to 15
- 16 to 25
- 26 to 40
- 41 to 60
- 61 to 100
- More than 100
- Other, as detailed in Note below
-
Number of below ground levels:
- Nil
- 1 basement
- 2 basements
- 3 basements
- 4 basements
- 5 basements
- 6 basements
- 7 basements
- 8 basements
- 9 or more basements
- Lower ground
- Lower ground plus 1 basement
- Lower ground plus 2 basements
- Lower ground plus 3 basements
- Lower ground plus 4 basements
- Lower ground plus 5 basements
- Lower ground plus 6 basements
- Lower ground plus 7 basements
- Lower ground plus 8 basements
- Other, as detailed in Note below
-
Lowest occupied level:
- Ground Floor
- Lower Ground Floor
- Basement
- Basement 2 or below
- 1st Floor
- 2nd Floor or Above
- Other, as detailed in Note below.
-
Building age:
- Recently completed < 1 year ago
- Built during 2020s
- Built 2010 to 2019
- Built 2000 to 2009
- Built 1990 to 1999
- Built 1980 to 1989
- Built 1970 to 1979
- Built 1960 to 1969
- Built 1940 to 1959
- Built 1900 to 1939
- Built 1800 to 1899
- Built before 1800
-
Heritage considerations:
- No heritage considerations
- Not relevant, as client does not insure building
- Heritage likely, considering building age
- Façade only has heritage significance
- Heritage significance by local council
- Heritage Listed in State / National Register
- Could not be determined
-
Building Condition:
- Excellent condition
- Good condition - well maintained
- Good condition - minor maintenance issue
- Average condition for age - reasonably maintained
- Average condition - some maintenance issues
- Below average condition - significant maintenance issues
- Poor condition - many significant maintenance issues
- Dilapidated condition - significant maintenance concerns
-
Building floor area (sq metres):
- Building footprint area
- Total building area of all levels
- Tenancy floor area:
-
Building footprint area (sq m) :
-
Total building area of all levels (sq m):
-
Tenancy floor area (sq m):
-
Building fire divisions / compartmentation
- Single fire risk
- Single fire risk with inadequately protected openings to fire-resistive walls / floors
- Fire compartments with self-supported fire-resistive walls with protected openings
- Fire compartments with self-supported fire-resistive walls without openings
- Partial fire compartment at each level with concrete floors, fire stopped penetrations but open stairs
- Partial fire compartment at each level with concrete floors, enclosed stairs, but open penetrations
- Fire compartment at each level with concrete floors, enclosed stairs, fire stopped penetrations
- Fire compartments within each level with fire-resistive walls and fire doors plus at each level with concrete floors, enclosed stairs and fire stopped penetrations
- Individual buildings are a single fire risk with adequate distance separation to other buildings.
-
Asbestos materials:
- Nil asbestos on site, confirmed by qualified audit or built after 2003.
- No apparent asbestos on site
- Unable to determine
- Asbestos to minor internal services only (e.g. Lagging, switchboards)external and internal surfaces
- Asbestos to internal surfaces
- Asbestos to sheltered external surfaces
- Asbestos to external and internal surfaces
- Asbestos to exposed external surfaces
- Other - as detailed in Note below
-
Asbestos Management:
- An Asbestos Management Plan &/or Asbestos Register in place with regular update audits
- An Asbestos Management Plan &/or Asbestos Register in place
- No Asbestos Management Plan or Asbestos Register available
- Asbestos materials are in good condition
- Asbestos materials have minor damage
- Asbestos materials have significant damage
-
Asbestos Percentage:
- Nil
- Less than 1%
- 1% to < 5%
- 5% to < 20%
- 20% to < 30%
- 30% to < 50%
- 50% or more
-
Plastic construction materials:
- No plastic construction materials
- Insulated Sandwich Panels (ISP)
- External cladding - Aluminium Composite Panels (ACP
-
Panel core material:
- EPS (expanded polystyrene, including fire-retardant EPS)
- Assumed EPS (expanded polystyrene, including fire-retardant EPS)
- PIR (polyisocyanurate) FM Approved Class 1
- PIR (polyisocyanurate) not FM Approved
- Xflam (FM Approved phenolic resin and EPS foam)
- Mineral Fibre (eg Rockwool)
- FM Approved Class 1
- PUR (polyurethane)
- Polyethylene
- Foil or paper faced expanded polystyrene
- Exposed combustible plastic core (no sheet metal face)
- Sprayed on exposed polyurethane foam
- Mixture of panel types (e.g. EPS and PIR), as detailed in Note below
- Other combustible, as detailed in Note below
- Other non-combustible, as detailed in Note below
-
Percentage of ISP by floor area of the building:
- Nil
- Less than 1%
- 1% to < 5%
- 5% to < 20%
- 20% to < 30%
- 30% to < 40%
- 40% to < 50%
- 50% to < 70%
- 70% or more
- Other, as detailed in Note below:
-
Panel Management Controls:
- Hot work procedures and permits in use
- Cold work procedures in place
- Informal hot work procedures
- Informal cold work procedures
- No hot / cold work controls in place
- Conduits to service penetrations in panels
- Conduits to most service penetrations but some unprotected penetrations to panels
- Unprotected penetrations to panels
- Switchboard / battery charger/ / ignition / heat source well separated
- Switchboard / battery charger/ / ignition / heat source close proximity
- Switchboard / battery charger/ / ignition / heat source in close proximity but adequate thermal barrier in place
- Formal panel condition self-inspections completed at least once a month
- Adequate regular panel inspections undertaken
- Ad-hoc informal panel condition inspections undertaken
- No regular panel condition self-inspections
- Adequate impact protection to panels
- Adequate impact controls in place (forklifts prohibited from ISP area)
- Partial impact protection to panels
- Inadequate impact protection to panels
- Other - as detailed in Note below
-
Condition of Panels
- Panels in good condition
- Some dented panels
- Extensive dents to panels
- Some exposed core material
- Extensive exposed core material
- Other - as detailed in Note below
-
Cladding / ACP combustibility
- Unable to determine combustibility of ACP
- Awaiting test results on ACP combustibility
- External panelling is combustible plastic / timber
- ACP has a core of >30% combustible polymer material (PE)
- ACP has a core of <=30% combustible polymer material (FR, A2, A1, NC)
- ACP is solid metal or honeycomb type
- External panelling is non-combustible material
- External panelling is non-combustible fibrous cement sheet
- Other, as detailed in Note below
-
Cladding / ACP percentage:
- Cladding panels are less than 1% of facades
- Cladding panels are less than 5% of facades
- Cladding panels are 5% to < 20% of facades
- Cladding panels are 20% to < 30% of facades
- Cladding panels are 30% to < 50% of facades
- Cladding panels are 50% to < 70% of facades
- Cladding panels are greater than 70% of facades
- Continuous vertical strips of composite panels to < 20% of facades
- Continuous vertical strips of composite panels between 20% and 50% of facades
- Continuous vertical strips of composite panels to more than 50% of facades
- Horizontal ring breaks of non-combustible panels / windows every level
- Horizontal ring breaks of non-combustible panels / windows every second level
- Horizontal ring breaks of non-combustible panels / windows every third level
- Horizontal ring breaks of non-combustible panels / windows every forth level
Construction Overview
-
Is there more than one building on site
-
Overall percentage of asbestos materials over total of all buildings on site:
- Nil
- Less than 1%
- 1% to < 5%
- 5% to < 20%
- 20% to < 30%
- 30% to < 40%
- 40% to < 50%
- 50% to < 70%
- 70% or more
- Other, as detailed in Note below:
-
Overall percentage of ACP / combustible cladding materials over total of all buildings on site:
- Nil
- Less than 1%
- 1% to < 5%
- 5% to < 20%
- 20% to < 30%
- 30% to < 40%
- 40% to < 50%
- 50% to < 70%
- 70% or more
- Other, as detailed in Note below:
-
Overall percentage of Insulated Sandwich Panel materials over total of all buildings on site:
- Nil
- Less than 1%
- 1% to < 5%
- 5% to < 20%
- 20% to < 30%
- 30% to < 40%
- 40% to < 50%
- 50% to < 70%
- 70% or more
- Other, as detailed in Note below:
Occupation
-
Overview of occupation, including any issues and non-standard features:
-
List of process activities:
- Nil
- Cooking
- Wood working
- Spray painting
- Vehicle smash repair
- Plastic injection molding
- Plastic blow moulding
- Plastic extrusion
- Commercial Printing
- Hot works such as welding, brazing, grinding
- Metal working
- Laundry
- Dangerous Goods Storage
- Storage / Warehouse
- Cold storage
- Battery Charging
- Waste Water Treatment
- Food manufacturing
- Food packing
- Winery
- Textile maufacturing
- Chemical / paint manufacturing
- Accommodation
- Live entertainment
- Gaming machines
- ATM / Cash Redemption Terminal
- Hardware stores
- Retailing
- Medical facility
- Offices
- Other, as detailed in Note below.
-
Type of cooking equipment:
- Benchtop Deep Fryer
- Floor Mounted Deep Vat Fryer
- Gas Oven
- Wok Burner
- Wok Deep Fryer
- Solid Fuel Cooking
- Wood fired oven
- Charcaol cooking
- Kebab cooking
- Smoker
- Microwave Oven
- Toaster
- Sandwich Press
- Combi-oven
- Standard refrigerator / freezer
- Walk-in Refrigerator
- Walk-in Freezer
- Ducted Extraction Rangehood
- Other, as detailed in Note below.
-
Rangehood Filter cleaning:
- Daily by contractor
- Weekly by contractor
- Fortnightly by contractor
- Monthly by contractor
- Quarterly by contractor
- Every six months by contractor
- Annually by contractor
- Daily by staff
- Weekly by staff
- Fortnightly by staff
- Monthly by staff
- Quarterly by staff
- Every six months by staff
- Annually by staff
- No regular cleaning of filters
- Cleaning appears adequate
- Cleaning frequency inadequate as filters observed to be clogged
- Other, as detailed in Note below
-
Rangehood internal duct / flue cleaning:
- Weekly by contractor
- Fortnightly by contractor
- Monthly by contractor
- Quarterly by contractor
- Every six months by contractor
- Annually by contractor
- Weekly by staff
- Fortnightly by staff
- Monthly by staff
- Quarterly by staff
- Every six months by staff
- Annually by staff
- No regular cleaning of internal ducting
- Cleaning frequency inadequate as grease observed dripping from bottom of filter
- Flue cleaning appears adequate
- Other, as detailed in Note below
-
Woodworking controls:
- No saw dust extraction / collection equipment
- Dust extraction / collection systems to most woodworking machines
- Dust extraction / collection systems to all woodworking machines
- Dust collection bags / hopper located inside building
- Dust collection bags / hopper located against outside of building
- Dust collection bags / hopper located well clear of building
- General daily clean-up procedures in place
- Weekly more thorough clean-up procedures in place
- Monthly more thorough clean-up procedures in place
- Annual major high level blow-down and clean-up procedures in place
- Annual major high level blow-down and clean-up procedures in place
- Adequate clean-up procedures in place
- Clean-up procedures below acceptable standard
- Unacceptable clean-up procedures
- Other, as detailed in Note below
-
Spray booth:
- Spray paint inside building without a spray booth.
- Spray paint inside building without a spray booth, but area well ventilated.
- Only spray paint outside building
- Approved open fronted spray booth in use
- Approved enclosed spray booth in use
- Paint / solvent mixing bench in general work area without fume extraction
- Paint / solvent mixing room without fume extraction
- Paint / solvent mixing room with approved type fume extraction system
- Only electrical equipment approved for use in hazardous atmosphere in use
- Non-hazardous area approved electrical equipment located in hazardous atmosphere area
- Other, as detailed in Note below
-
Flammable liquids controls:
- All solvents stored and dispensed from inside approved flammable liquids cabinets
- Most solvents stored inside approved flammable liquids cabinets but in-use solvent dispensed in general area.
- Solvents stored in non-approved cabinets
- Solvents stored in general area.
- Drums of solvent kept sealed when not in use.
- Drums of solvent observed open / without lid.
- Solvent soaked rags dispensed in plastic general waste bin.
- Solvent soaked rags dispensed in general metal waste bin.
- Solvent soaked rags dispensed in approved type flammables metal waste bin with self-closing lid.
- Static straps / earth bonding in use during dispensing.
- Static straps / earth bonding not provided during dispensing.
- Other, as detailed in Note below
-
Smash repair controls:
- Inadequate separation between spray painting and physical smash repair operations.
- Adequate clear space separation between spray painting and physical smash repair operations.
- Spray painting and physical smash repair operations located in separate rooms / sections of building.
- Vehicles awaiting repairs securely stored inside building.
- Vehicles awaiting repairs stored in securely fenced yard.
- Vehicles awaiting repairs stored in poorly securely fenced yard.
- Some vehicles awaiting repairs stored in open yard / common parking area.
- Some vehicles awaiting repairs stored in public street.
- Other, as detailed in Note below
-
Plastic moulding controls:
- All machines thermostatically controlled with auto shut-down on fault.
- All machines thermostatically controlled but manual shut-down required if fault.
- Not all machines thermostatically controlled with auto shut-down on fault.
- Machines heating system not thermostatically controlled
- Moulding equipment only operate under human supervision.
- Moulding equipment may operate without human supervision.
- Moulding equipment may operate without human supervision but monitored remotely via CCTV.
- Moulding equipment may operate without human supervision but stringent automatic controls in place.
- Heating element section of moulding equipment fitted with thermal insulation barrier / blanket
- Heating element section of moulding equipment not fitted with thermal insulation barrier / blanket
- Other, as detailed in Note below
-
Plastic moulding controls:
- All machines thermostatically controlled with auto shut-down on fault.
- All machines thermostatically controlled but manual shut-down required if fault.
- Not all machines thermostatically controlled with auto shut-down on fault.
- Machines heating system not thermostatically controlled
- Moulding equipment only operate under human supervision.
- Moulding equipment may operate without human supervision.
- Moulding equipment may operate without human supervision but monitored remotely via CCTV.
- Moulding equipment may operate without human supervision but stringent automatic controls in place.
- Heating element section of moulding equipment fitted with thermal insulation barrier / blanket
- Heating element section of moulding equipment not fitted with thermal insulation barrier / blanket
- Other, as detailed in Note below
-
Plastic moulding controls:
- All machines thermostatically controlled with auto shut-down on fault.
- All machines thermostatically controlled but manual shut-down required if fault.
- Not all machines thermostatically controlled with auto shut-down on fault.
- Machines heating system not thermostatically controlled
- Moulding equipment only operate under human supervision.
- Moulding equipment may operate without human supervision.
- Moulding equipment may operate without human supervision but monitored remotely via CCTV.
- Moulding equipment may operate without human supervision but stringent automatic controls in place.
- Heating element section of moulding equipment fitted with thermal insulation barrier / blanket
- Heating element section of moulding equipment not fitted with thermal insulation barrier / blanket
- Other, as detailed in Note below
-
Printing controls:
- Minimal flammable /solvents in printing area.
- Significant volumes of flammable /solvents not adequately stored.
- Significant volumes of flammable /solvents with most stored within approved flammable liquid cabinets.
- Bulk flammables / solvent stored in approved type flammable liquids store with only daily requirements in printing area.
- Bulk flammables / solvent stored in external flammable liquids store with only daily requirements in printing area.
- Waste solvent soaked rags placed in approved metal bins with self-closing lids.
- Waste solvent soaked rags placed in metal bins without lids.
- Waste solvent soaked rags inadequately disposed of.
- Approved flammable liquid containers used to store and dispense flammables / solvents.
- Inadequate containers used to store and dispense flammables / solvents, (e.g. plastic squirt bottles)
- Printing inks are non-flammable water / plant based.
- Printing inks are flammable oil / solvent based.
- Machinery appears well maintained with no leaks observed.
- Machinery has some oil leaks observed, indicating inadequate maintenance.
- Other, as detailed in Note below
-
Hot work controls:
- No formal hot work procedures or permit in place.
- Only informal hot work controls in place.
- Formal hot work procedures and permit in place, including 60 minute Firewatch.
- Formal hot work procedures and permit in place, but inadequate Firewatch period.
- Dedicated hot work area established for regular hot work activities.
- Hot work is rare at this site.
- Depend on outside contractor to instigate their own hot work procedures.
- Other, as detailed in Note below
-
Are hazardous process activities adequately controlled?
-
Details of deficienciesies with process controls:
-
Housekeeping:
- The standard of housekeeping throughout the site is poor
- The standard of housekeeping throughout the site is below standard
- The standard of housekeeping throughout the site is satisfactory
- The standard of housekeeping throughout the site is generally good, with some areas of minor concern
- The standard of housekeeping throughout the site is good
- The standard of housekeeping throughout the site is very good
- The standard of housekeeping throughout the site is very good. Contract cleaners are on site overnight, 7 days a week
- Other, as detailed in Note below
Electrical
-
Thermal imaging of electrics:
- There is no scheduled thermal imaging of electrics at this site.
- There is no scheduled thermal imaging of electrics at this site, but not considered necessary.
- Unable to determine if thermal imaging of electrics is undertaken.
- Thermal imaging of electrics not conducted in recent years.
- Thermal imaging of electrics conducted on an ad-hoc basis, with the last done more than two years ago.
- Thermal imaging of electrics conducted on an ad-hoc basis, with the last done within last year.
- Thermal imaging of electrics conducted on a programmed basis every three years.
- Thermal imaging of electrics conducted on a programmed basis every two years.
- Thermal imaging of electrics conducted on a programmed annual basis, but still to rectify identified issues.
- Thermal imaging of electrics conducted on a programmed annual basis.
- Thermal imaging of electrics conducted on a programmed basis every six months.
- Thermal imaging of electrics conducted by trained on-site maintenance team at least twice a year.
- Other, as detailed in Note below.
-
Test & Tagging of portable equipment:
- There is no scheduled test and tagging of electrical equipment and extension leads at this site.
- There is no scheduled test and tagging of electrical equipment and extension leads at this site, but not considered necessary.
- Unable to determine if test and tagging of electrical equipment is undertaken.
- This is a multi-tenanted property owner's risk, test and tagging is the responsibility of tenants.
- Test and tagging of electrical equipment and extension leads completed on a programmed basis at this site.
- Test and tagging of electrical equipment and extension leads completed on a programmed annual basis at this site.
- Test and tagging of electrical equipment and extension leads and RCD testing completed on a programmed annual basis at this site.
- Test and tagging of electrical equipment and extension leads completed on a programmed basis at least twice a year.
- Test and tagging of electrical equipment and extension leads and RCD testing completed on a programmed basis at least twice a year.
- Other, as detailed in Note below.
-
Solar PV System
- There is no solar PV system at this site.
- There is a solar PV system with roof mounted solar panels and DC inverters at this site.
- There is a solar PV system with roof mounted solar panels, DC inverters and battery energy storage system at this site. Building exposed to battery.
- There is a solar PV system with roof mounted solar panels, DC inverters and battery energy storage system at this site. Building not exposed to battery.
- There is a solar PV system with ground mounted solar panels and DC inverters at this site.
- Other, as detailed in Note below.
-
Solar system capacity:
- 1 to 20 solar panels
- 21 to 100 solar panels
- 101 to 500 solar panels
- Greater than 500 solar panels
- Solar PV system <=5kW
- Solar PV system between 5kW and 10kW
- Solar PV system between 10 kW and 50 kW
- Solar PV system between 50 kW and 100 kW
- Solar PV system between 100 kW and 500 kW
- Solar PV system between 500 kW and 1 MW
- Solar PV system between 1 MW and 10 MW
- Solar PV system over 10 MW
-
Power Generators
- No back-up power generator on site.
- There is no back-up power generator on site. A loss of power at site would interrupt operations and/or risk stock spoilage.
- There is no back-up power generator on site, however IT systems are provided with a UPS battery system.
- There is no back-up power generator on site, however a connection point has been installed for an external portable generator.
- Back-up power generation on site with capacity for emergency services only.
- Back-up power generation on site with capacity for critial operations only.
- Back-up power generation on site with capacity for 100% of operations load.
-
Generator maintenance:
- Maintenance not applicable to UPS or connection point.
- No programmed testing or maintenance of on-site generator.
- Programmed regular maintenance of on-site generator.
- Programmed monthly maintenance but no testing under load of on-site generator.
- Programmed monthly maintenance and annual testing of on-site generator.
- Programmed monthly maintenance and test run under load at least annually of on-site generator.
-
External housekeeping:
- Good external housekeeping, with no combustible storage exposure to outside of building.
- Idle pallets and other combustible materials are relocated inside the building overnight.
- Idle pallets and other combustible materials are located well clear the building overnight.
- Idle pallets and other combustible materials are located adjacent to the ouside blank parapet masonry wall of the building overnight.
- Idle pallets and other combustible materials are located adjacent to the ouside of the masonry wall of the building overnight.
- Idle pallets and other combustible materials are located adjacent to the ouside wall of the building with exposed openings overnight.
- Industrial waste bins are located in the yard, well clear of the building.
- Industrial waste bins are located adjacent to the ouside blank parapet masonry wall of the building.
- Industrial waste bins are located adjacent to the ouside of the masonry wall of the building.
- Industrial waste bins are located adjacent to the ouside wall of the building with exposed openings.
- Industrial waste bins are located inside the building overnight
- Bins are located in an unsecured enclosure.
- Bins are located in a well secured enclosure.
- Bins are padlocked / secured overnight.
- Bins are not padlocked / not secured overnight.
- Other, as detailed in Note below
Fire Protection
-
Fire protection provided:
- Fire Blanket
- Fire Extinguishers
- Fire Hose Reel
- Fire Hydrant
- Fire Detection
- Local Fire Suppression system
- Fire Sprinkler
- Fire Water Supply
- Exit Signs & Emergency Lighting
- Occupant Warning System
- Evacuation Procedures
- Staff Fire Training
- Fire Brigade
- Other, as detailed in Note below
-
Fire Blanket:
- No fire blanket provided.
- Inadequatly sized fire blanket.
- Fire blanket not easily accessible.
- Fire blanket, mounted in easily accessible position.
- Other, as detailed in Note below
-
Fire Extinguishers:
- No fire extinguishers provided.
- Inadequate fire extinguishers installed.
- Fire extinguishers provided to part of premises.
- Fire extinguishers installed with improvements recommended for type of extinguisher.
- Fire extinguishers installed with improvements recommended for additional extinguishers.
- Adequate fire extinguishers provided.
-
Fire Extinguisher maintenance:
- Not applicable
- Extinguishers are not regularly maintained and access to some equipment obstructed.
- Extinguishers are not regularly maintained.
- No maintenace tag on extinuishers, therefore assume not maintained.
- Extinguishers are maintained annually, but some has been missed and access to some equipment was obstructed.
- Extinguishers are maintained annually, but some equipment has been missed.
- Extinguishers are maintained annually, but access to some equipment obstructed.
- Extinguishers are maintained annually.
- Extinguishers are maintained twice a year in accordance with AS1851, but some has been missed and access to some equipment was obstructed.
- Extinguishers are maintained twice a year in accordance with AS1851, but some has been missed.
- Extinguishers are maintained twice a year in accordance with AS1851, but access to some equipment was obstructed.
- Extinguishers are maintained twice a year in accordance with AS1851.
- Other, as detailed in Note below
-
Fire Hose Reels:
- No fire hose reels provided.
- Inadequate fire hose reels installed.
- Fire hose reels provided to part of premises.
- Fire hose reels installed with improvements recommended for coverage.
- Adequate fire hose reels provided.
- Other, as detailed in Note below
-
Fire Hose Reels maintenance:
- Not applicable
- Fire hose reels are not regularly maintained.
- Fire hose reels are not regularly maintained and access to some equipment obstructed.
- Fire hose reels are maintained annually, but some has been missed and access to some equipment was obstructed.
- Fire hose reels are maintained annually, but some equipment has been missed.
- Fire hose reels are maintained annually, but access to some equipment obstructed.
- Fire hose reels are maintained annually.
- Fire hose reels are maintained twice a year in accordance with AS1851, but some has been missed and access to some equipment was obstructed.
- Fire hose reels are maintained twice a year in accordance with AS1851, but some has been missed.
- Fire hose reels are maintained twice a year in accordance with AS1851, but access to some equipment was obstructed.
- Fire hose reels are maintained twice a year in accordance with AS1851.
- Other, as detailed in Note below
-
Fire Hydrants:
- No fire hydrants available.
- Fire hydrants available in public roadway.
- Fire hydrants installed to external areas of premises.
- Fire hydrants installed to internal areas of premises.
- Fire hydrants installed to external and internal areas of premises.
- Fire hydrants installed in public roadway and external areas of premises.
- Fire hydrants installed in public roadway and internal areas of premises.
- Fire hydrants installed in public roadway, external and internal areas of premises.
- Other, as detailed in Note below
-
Fire Hydrants maintenance:
- Not applicable
- Fire hydrant system not regularly maintained.
- Fire hydrant system not maintained in recent years.
- Fire hydrant system regularly maintained to AS 1851.
- No annual hydrant flow test provided.
- Failed the last annual hydrant flow test conducted more than 1 year ago.
- Failed the annual hydrant flow test conducted within the last year.
- Passed the latest annual hydrant flow test conducted more than 1 year ago.
- Passed the annual hydrant flow test conducted within the last year.
- Other, as detailed in Note below
-
Fire Detection type:
- Smoke detectors
- Aspirated smoke detection (VESDA)
- Thermal detectors
- Flame detectors
- Local alarm, not remotely monitored.
- Sends alarm to staff's mobile phone.
- Sends alarm to on-site security room.
- Connected to remotely monitored security alarm system.
- Connected to a fire alarm panel with ASE to a third-party fire alarm monitoring company through to the public fire brigade.
- Other, as detailed in Note below
-
Fire Detection maintenance:
- Fire detection system not regularly maintained.
- Maintained periodically as part of security alarm system
- Fire detection system maintained 1 to 4 times a year.
- Fire detection system maintained monthly to AS 1851.
- No faults / isolations on fire alarm panel.
- Current fault / isolation on fire alarm panel.
- Faults / isolations on fire alarm panel, unresolved for more than two months.
- Other, as detailed in Note below
-
Localised Fire Supression coverage:
- No fire suppression system provided.
- Fire sprinklers positioned within kitchen rangehood.
- A localised fire suppression system provided to some kitchen rangehoods, with manual activation.
- A localised fire suppression system provided to all kitchen rangehoods, with manual activation.
- A localised fire suppression system provided to some kitchen rangehoods, with automatic and manual activation.
- A localised fire suppression system provided to all kitchen rangehoods, with automatic and manual activation.
- Other, as detailed in Note below
-
Fire Supression maintenance:
- Not applicable
- Fire suppression system not regularly maintained.
- Fire suppression system maintained 1 to 4 times a year, with faults / isolations on fire alarm panel, unresolved for more than two months.
- Fire suppression system maintained 1 to 4 times a year, with faults / isolations on fire alarm panel.
- Fire suppression system maintained 1 to 4 times a year, with no defects noted.
- Fire suppression system maintained monthly to AS 1851, but faults / isolations on fire alarm panel, unresolved for more than two months.
- Fire suppression system maintained monthly to AS 1851, but fault / isolation on fire alarm panel.
- Fire suppression system maintained monthly to AS 1851, with no defects noted.
- Other, as detailed in Note below
-
Sprinkler System design:
- Unable to determine - no block plan available / insured not in control of system
- A variety of designs for specific areas, as detailed in Note below.
- Designed to AS 2118 Residential design.
- Designed to AS 2118 Light Hazard design
- Designed to AS 2118 Light Hazard design, with 6 heads @ 48 l/min.
- Designed to AS 2118 Ordinary Hazard
- Designed to AS 2118 Ordinary Hazard III, with a density of 5mm over 72 m².
- Designed to AS 2118 High Hazard
- Designed to AS 2118 High Hazard with a density of 12.5 mm/min over 260 m².
- Designed to AS 2118 & FM data sheet, ESFR
- Designed to AS 2118 & FM data sheet, ESFR with K16 heads - 20 heads @ 350 kPa
- Designed to AS 2118 & FM data sheet, ESFR with K24 heads - 12 heads @ 240 kPa
- Designed to AS 2118 & FM data sheet, ESFR with K36 heads - 12 heads @ 350 kPa
- Designed to CA-16 / Old Rules
- Other, as detailed in Note below
-
Sprinkler System maintenance:
- Unable to determine - no logbook available / insured not in control of system
- Sprinkler system maintained weekly in accordance with AS 1851.
- Sprinkler system maintained monthly in accordance with AS 1851.
- Sprinkler system is not regularly maintained.
- Sprinkler system is not operational.
- No faults observed nor indicated in logbook.
- Faults indicated in logbook outstanding for more than two months.
- No annual sprinkler flow test provided.
- Failed the last annual sprinkler flow test conducted more than 1 year ago.
- Failed the annual sprinkler flow test conducted within the last year.
- Passed the latest annual sprinkler flow test conducted more than 1 year ago.
- Passed the annual sprinkler flow test conducted within the last year.
- Other, as detailed in Note below
-
Sprinkler System monitoring:
- Unable to determine - no logbook available / insured not in control of system
- The system is connected to a fire alarm panel and remotely monitored with an ASE to a third-party fire alarm monitoring company through to the public fire brigade.
- The system is monitored via an ASE through to the fire brigade.
- The system is monitored via the monitored security alarm system.
- The system is monitored by the on-site security room.
- The system is not remotely monitored.
- Other, as detailed in Note below
-
Sprinkler System Adequacy:
- Unable to determine adequacy of the fire sprinkler system as the sprinkler design details were not available to compare with the observed commodities stored, storage heights and storage arrangements.
- The fire sprinkler system appears adequate considering the sprinkler design and the observed storage commodities, storage heights and storage arrangements.
- The fire sprinkler system appears adequate considering the sprinkler design and the observed storage commodities, storage heights and storage arrangements, however there were some minor issues to be rectified.
- The fire sprinkler system appears not to be adequate, as the sprinkler design does not match aspects of the observed commodities stored, storage heights and storage arrangements.
- Sprinkler system is not operational.
- Other, as detailed in Note below
-
Fire water supply:
- Unable to determine - insured not in control of system
- Single water supply from the town main.
- A single connection to the town main in the public roadway.
- Single water supply from an on-site tank.
- On-site water tank fed from bore water using electric pump.
- Dual water supply from a tank and the town main.
- Dual water supply from connections to two town mains.
- The combined sprinkler and hydrant system have a single water supply from the town main.
- The combined sprinkler and hydrant system have a dual water supply from an on-site tank with automatic in-fil from the town main.
- The combined sprinkler and hydrant system have a dual water supply from connections to two town mains.
- Single water supply is from an on-site dam.
- Single water supply is from an irrigation canal.
- Single water supply is from a river.
- Other, as detailed in Note below
-
Exit Signs and Emergency Lighting:
- No exit signs nor emergency lighting installed.
- Exit signs installed but some not functioning.
- Exit signs installed but some not functioning, emergency lights provided.
- Exit signs installed but no emergency lighting.
- Exit signs and emergency lighting installed.
- Other, as detailed in Note below
-
Occupant Warning System:
- No Occupant Warning System.
- Public address system used as site's occupant warning system.
- Portable compressed air horn used as site's occupant warning system.
- Siren used as site's occupant warning system.
- Occupant warning system installed.
- Emergency warning intercommunication system (EWIS) installed
- Other, as detailed in Note below
-
Emergency Procedures:
- No Emergency Procedures in place.
- Site contact unaware of any Emergency Procedures for the site.
- Only informal Emergency Procedures in place.
- Formalised emergency management plan in place.
- Formalised emergency management plan in place including wardens assigned to cover all shifts for designated areas.
- No emergency plan / diagram displayed.
- Outdated emergency plan / diagram displayed within the premises.
- Current emergency plan / diagram displayed within the premises.
- Evacuation drills have not been conducted.
- Evacuation drills have not been conducted in recent years.
- Evacuation drills are conducted once a year.
- Evacuation drills are conducted twice a year.
- Emergency organisation wardens have not received training in recent years.
- Emergency organisation wardens receive training once a year.
- Emergency organisation wardens receive training twice a year.
- Other, as detailed in Note below
-
Staff Fire Training:
- No training in the use of fire-fighting equipment provided to staff.
- No training in the use of fire-fighting equipment provided to staff. The preferred option is evacuation only
- Training in the use of fire-fighting equipment provided to selected staff every two years
- Training in the use of fire-fighting equipment provided to selected staff.
- Training in the use of fire-fighting equipment provided to all staff.
- On-line training in the use of the fire-fighting equipment is provided to selected staff.
- On-line training in the use of the fire-fighting equipment is provided to all staff.
- Training conducted a few years ago.
- Training conducted every two years.
- Training conducted once a year.
- Training conducted twice a year.
- Other, as detailed in Note below
-
Fire Brigade:
- Full-time permanently occupied by professional fire-fighters
- One full time officer plus retained firefighters
- One full time officer plus volunteer firefighters
- Retained Firefighters
- Volunteer brigade
- Private trained fire team on site
- Nil Fire Brigade in area.
- Satisfactory response time expected (<10 minutes)
- Extended response time expected (10 to 30 minutes minutes)
- Unsatisfactory response time expected (>30 minutes)
- Fire brigade have not visited the site for familiarisation purposes
- Fire brigade have not visited the site for familiarisation purposes in recent years
- Fire brigade have only visited the site in response to false alarms in recent years
- Fire brigade visited the site for familiarisation purposes within last two years
- Other, as detailed in Note below
-
Other Fire Protection:
Security
-
Electronic Security Alarm System:
- No security alarm installed
- Property owner of multi-tenanted site, with some individual tenancies having their own security systems.
- Electronic security alarm installed - but inadeqaute coverage
- Electronic security alarm installed with adequate coverage
- Monitoring details unknown.
- Local, no remote monitoring
- Monitored to staff's mobile phone
- Monitored by on-site security
- Monitored by professional security alarm monitoring company.
- No Panic / Duress button
- Panic / Duress button - fixed type
- Panic / Duress button - portable type
- Other, as detailed in Note below
-
CCTV System:
- No CCTV system installed
- Property owner of multi-tenanted site, with some individual tenancies having their own CCTV systems.
- CCTV system installed
- Adequate camera coverage
- Inadequate camera coverage
- Not recording
- Recording capacity - up to 7 days
- Recording capacity - 8 to 20 days
- Recording capacity - 21 to 30 days
- Recording capacity - 31 to 90 days
- Recording capacity - over 90 days
- Recording capacity - unknown
- Local viewing only
- Video footage may be viewed remotely on staff's mobile / home computer
- Video footage may be viewed remotely by the security alarm monitoring company
- Other, as detailed in Note below
-
Security Guards:
- Nil security patrols.
- Staff live on site.
- Security guards only visit on response to alarm activation.
- Security guards visit site for patrols once a overnight and weekends.
- Security guards visit site for external patrols a number of times overnight and weekends.
- Security guards visit site for external / internal patrols a number of times overnight and weekends.
- Security guards remain on site after operating hours.
- Security guards remain on site 24 hours / 7 days
- Trained guard dogs in yard area overnight.
- Other, as detailed in Note below
-
Adequate security measures in place
- Yes
- Yes, considering property owners risk only.
- Yes, considering no theft coverage.
- No
- No, considering high Theft sum insured.
Exposures
-
Neigbouring Exposures:
- Well detached by clear distance from neighbouring exposures.
- Adequate distance separation from neighbouring exposures.
- Well separated by blank parapet masonry walls from neighbouring buildings in close proximity.
- Partial Separation by distance from neighbouring exposures.
- Partial Separation by fire resistive construction from neighbouring exposures.
- Inadequate Separation from lower hazard neighbouring exposures.
- Inadequate Separation from similar hazard neighbouring exposures.
- Inadequate Separation from higher hazard neighbouring exposures.
- Buildings on site are well detached by distance from each other as well as from neighbouring buildings.
- Buildings on site are detached from each other with adequate distance separation from neighbouring exposures.
- Other, as detailed in Note below
-
Natural Perils
- No unusual natural perils exposures.
- Storm / Wind
- Hail
- Flood
- Stormwater Flood
- Action by the Sea
- Cyclone
- Lightning
- Bushfire
- Earthquake
- Other, as detailed in Note below
Business Interruption
-
Business Interruption
- Building owner, standard building do not expect any major delays to reinstate building and resume operations.
- Building owner of non-standard building which would require significant time to obtain approvals, reinstate building and resume operations.
- Lease premises, therefore would relocate to an alternative premises and replace stock and contents in a relatively short period.
- Lease premises, however specialist equipment would need to be ordered and imported from overseas, with significant delay in resuming operations.
- Building owner / occupier, therefore would require significant time to reinstate building and order / import specialist equipment with significant delay in resuming operations.
- There is a high degree of redundancy in the production process with multiple production lines.
- There are limited alternate suppliers for this business.
- There are many alternate suppliers for this business.
- The site contact was unaware of any formal business continuity plan for this site
- There is no formal business continuity plan in place specifically for this site
- There is a formal business continuity plan in place specifically for this site, however, this is limited to information technology services.
- There is a formal business continuity plan in place specifically for this site. The BCP includes alternative sites and partnerships with suppliers for alternate storage facilities
- There is a formal business continuity plan in place specifically for this site, which is reviewed regularly. Should a major event occur there is the provision to increase production at their other locations, with some associated additional costs.
- Other, as detailed in Note below
-
Computer Records Back-up
- There are no procedures to back-up computer records.
- The computer records are backed up daily onto an external hard-drive and left in the same office.
- The computer records are backed-up daily onto a USB memory stick which stays in the office. Financial records are emailed daily to the offsite accountant.
- The computer records are backed up daily onto an external hard-drive kept in the security safe on site.
- The computer records are backed up daily onto an external hard-drive kept inside a propriety fire rated computer media storage container on site.
- The computer records are backed up daily onto an external hard-drive that is taken offsite nightly with the same hard-drive returned the next morning.
- The computer records are backed up daily onto one of a number of external hard-drives that is taken offsite nightly with an alternative hard-drive returned on a rotating basis the next morning.
- The computer network server is linked continually on-line to the "Cloud"
- The computer records are backed up twice a week with a copy on-line to the “cloud” and a second copy onto an external hard-drive kept in the security safe on site.
- The computer network server is linked continually on-line to their head office who look after computer records back-up procedures.
- The computer network server is linked continually on-line to their head office who look after computer records back-up procedures which includes operating 2 mirror servers and daily offsite back-up of records.
- The SCADA process control system is backed up separately at the production area and engineering office.
- Not applicable, as property owner's risk only.
- Other, as detailed in Note below.
-
Indemnity Period we recommend
Risk Improvement Recommendations
-
Actions marked as "Critical" actions address major deficiencies in controls that fall short of best industry practices or recognised standards. These actions are necessary when there's a high likelihood of a loss event, and the potential consequences are significantly greater due to inadequate controls.
-
Actions marked as "Recommended" – Recommendation to address deficiencies in relation to the level of controls whereas they do not meet best industry practice and recognised standards. Deficiency may increase the likelihood of a loss event, or consequence in the event of a loss event.
-
Actions marked as "Best Practice Advisory" – Considered to be best industry practice with a low likelihood and consequence in relating to loss exposure.
-
Are there any risk recommendations?
Fire and Life Safety Recommendations
-
undefined
-
Recommended Priority
Electrical Risk Recommendations
-
undefined
-
Recommendation Priority
House Keeping Recommendations
-
undefined
-
Recommendation Priority
Occupation Recommendations
-
undefined
-
Recommendation Priority
Management Controls
-
undefined
-
Recommendation Priority
Security Recommendation
-
undefined
-
Recommendation Priority
Cash Management Recommendations
-
undefined
-
Recommendation Priority
Natural Perils / Other Exposures Recommendations
-
undefined
-
Recommendation Priority
Separation Recommendations
-
undefined
-
Recommendation Priority
Values at Risk Recommendations
-
undefined
-
Recommendation Priority
Liability Recommendations
-
undefined
-
Recommendation Priority
Other Risk Recommendations
-
undefined
-
Recommendation Priority
Survey Summary
-
Survey Status
-
Hazard class
- Standard Hazard Class
- ISP / EPS Hazard Class (>20% EPS)
- ISP / PIR/Xflam Hazard Class (>50% PIR/Xflam)
- Asbestos Hazard class (>30% asbestos)
- High Hazard Class
- Alpine Hazard Class
-
Construction Classification
- Fire resistive construction (min. 2 hour fire resistance rating)
- Non-combustible construction
- Mixed construction (<20% combustible / inferior)
- Combustible / inferior (≥20% asbestos / ISP) construction
-
Fire load and fire spread risk
- Low fire load, expected limited fire spread within premises.
- Low fire load, expect fire to spread throughout building.
- Medium fire load, expected limited fire spread within premises.
- Medium fire load, expect fire to spread throughout premises.
- High fire load, expected limited fire spread within premises.
- High fire load, expect fire to spread throughout premises.
- Very high fire load, expected limited fire spread within premises.
- Very high fire load, expect fire to spread throughout premises.
- Other, as detailed in Note below
-
Loss Expectancy:
- Single building presenting as a single fire risk, expect total loss in a fire.
- Single building with internal compartmentation, expect partial loss in a fire, as detailed in Note below..
- Single building with inadequate internal compartmentation, expect total loss in a fire, as detailed in Note below..
- Single building with internal compartmentation and sprinkler system protection, expect partial loss in a fire, as detailed in Note below..
- Single building with adequate sprinkler system protection, expect partial loss in a fire, as detailed in Note below..
- Single building with significant concerns with sprinkler system protection, expect a total loss in a fire, as detailed in Note below..
- Multiple buildings presenting as a single fire risk, expect total loss in a fire.
- Multiple buildings with adequate separation, expect partial loss in a fire, as detailed in Note below..
- Other, as detailed in Note below
-
Values at risk
- Acceptable - sums insured appear adequate
- Unacceptable - sums insured potentially under insured
- Sums insured may represent market value, not replacement value and therefore may be overinsured.
-
Client attitude towards risk management?
- The client is risk minded and has a proactive attitude to risk management.
- The client has an acceptable attitude to risk management.
- The client has a below average attitude to risk management.
- The client has a poor attitude to risk management.
- Insured is property owner, so limited influence over tenant implementing recommendations.
- Insured is property owner, however, tenant likely to implement recommendations.
- Insured is property owner, and do not expect tenant to implement recommendations.
- Site contact indicated a positive attitude and likely to implement risk recommendations.
- Site contact indicated an uninterested attitude and unlikely to implement risk recommendations.
- Site contact indicated they would not implement certain risk recommendations.
- Other, as detailed in Note below
-
Attach PDF of visual report from Blitz as media
-
Visual report
-
Acceptability
- Superior quality risk.
- Above average quality risk.
- Average quality risk.
- Below average quality risk.
- Poor quality risk.
- Acceptable risk, as is.
- Acceptable risk, provided client implements risk improvement recommendations.
- Acceptable risk, provided client implements all "Critical" risk improvement recommendations.
- Unacceptable risk, until client implements all "Critical" risk improvement recommendations.
- Unacceptable risk, as it is outside the SafetyCulture Care underwriting guidelines.
- Unacceptable risk, from an underwriting perspective.
- Unacceptable risk, due to serious issues discovered during survey.
- Unacceptable risk.
-
Are there any expected changes in the next twelve months
-
What are the changes?
-
Recommended that the client uses the SC Platform (Inspections, Training, Sensors etc)
-
Notify Anna Lorimer and Luke Robinson via action created to Anna Lorimer
-
When does this risk need to be surveyed next?
-
Action includes re-setting the survey booking for 3 months prior to renewal in 1, 2 or 3 years time