Aerial Drop

  • SDS Installed to specification

  • Correct Port used at MPT

  • Minimum Clearance maintained from Power Authority Assets

  • All fittings and terminations to specification

  • Drop cable slack loops secured with cable ties

  • Drop cable secured to pole as per specifications

  • Attachment at premises to specifications

  • Drop cable clear of vegetation

  • Drop cable tagged at both ends (MPT & PCD)

  • All fittings & terminations to intermediate poles to specifications

  • Sufficient space under eaves for bend radius of the drop cable

Premise Connection Device (PCD)

  • Minimum 1m radial distance from any power source, including the point where the premises power supply cable connects to the property barge

  • Minimum 150mm from exterior structure such as window or balcony

  • Minimum 150mm from corner of wall

  • minimum 300mm allowed to open the PCD door

  • minimum 300mm allowed to open the PCD door

  • Mechanical Connector terminated on drop fibre & housed correctly in PCD

  • Drop cables entering PCD from bottom only

General

  • Has there been an acceptable reinstatement and clean up of the end users property

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.