Information
-
Audit Title
-
Document No.
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
Project
-
Customer Service Area
-
Viscore no/Job no
-
Auditee:
-
Responsible manager
-
Company name:
3 Service Order
-
3.004 NTS test results OK
4 Codes
-
4.004 Correct Statement of Work codes used
5 Fault
-
5.009 Escalation procedure followed (Defect Referral)
6.000 Work areas & safety
-
6.001 personal and site safety procedures observed
-
6.002 hazards identified & recorded - worksite audit form completed / hazard notices in place<br>
-
6.003 Transit TMP provided
-
6.004 services located
-
6.005 power and gas clearances correct
-
6.008 network security correct (exchange)
-
6.012 temporary work clearly labelled and contains name, contact details, job ID of person involved
9 MDF (7535, NDF-100A, NDF-100B, ND0066)
-
9.001 MDF Block secure (installation, earthing)
-
9.002 MDF Block Labelling correct (Cable Number, Pair range)
-
9.003 MDF Area cable entry duct sealed
-
9.005 Jumper routing via frame guides
-
9.006 Jumper type correct (OR/WH) with required (175mm - 225mm) slack left
-
9.007 IDC jumper terminations correct (full insertion to IDC, excess trimmed)
-
9.008 Solder jumper terminations correct (wire strip & wrap, no excess solder)
-
9.009 Old jumpers removed
-
9.01 Lightning protection (where fitted) earth to common earth
-
9.011 Cable pair records updated
10 Pride & Logs
-
10.002 MDF Log completed in exchange
-
10.003 Equipment Room Log completed in exchange
-
10.004 Cabinet Log completed
25 Poles
-
25.003 Pole in good condition, no splits, burs
-
25.01 Pole safe to climb (hammer/probe/dig)
-
25.012 Plant positioned correctly and safely, plant clearances correct
-
25.013 Stub poles or staying lines or screw anchors installed correctly
-
25.014 Unsafe poles labelled / marked for replacement/7 days
-
25.015 Unsafe poles noted in Hazardous Pole Register
31 Active Cabinet Internal RHS
-
31.001 Outer Door lock works smoothly and door closes without jamming
-
31.002 Door stays are in place and all work well
-
31.004 Soft foam seal plate secured. Cable entry prevents vermin/insect entry.
-
31.006 MDF; Correct Modules installed
-
31.007 MDF; Module Labelling correct
-
31.008 MDF; Data card for jumper running data (laminated or in a card holder attached to the inside of door)
-
31.009 MDF; Cabinet E-side Termination data card in door.
-
31.01 MDF; Jumper correct type (BL/WH)
-
31.011 MDF; Jumper run correctly (50mm slack & no excess)
-
31.016 Bottom LHS Earth bar strapped to each MDF vertical and the base of the cabinet
-
31.02 MDF; Jumper terminated correctly
-
31.021 Door seals in good condition
-
31.023 MDF: All dead jumpers removed
37 Passive Copper Cabinet
-
37.001 Outer Door lock works smoothly and door closes without jamming
-
37.002 Door stays are in place and all work well
-
37.003 Cabling run correctly
-
37.004 Distribution Frame: Correct Modules installed
-
37.005 Distribution Frame: Module Labelling correct
-
37.006 Distribution Frame: Data card (laminated or in a card holder attached to the inside of CCC door)
-
37.007 Distribution Frame: Cabinet Laminated E-side Termination data card in door.
-
37.008 MDF; Jumper correct type (BL/WH)
-
37.009 MDF; Jumper run correctly (50mm slack & no excess)
-
37.01 MDF: All dead jumpers removed
-
37.011 Module support bars, separators and cover in place
-
37.013 Lightning protection installed (when specified) or reinstated after testing
-
37.014 All duct seals in place
-
37.015 Concrete around ducts in base of cabinet
-
37.016 Locks & hinges OK
-
37.017 Door seals in good condition
-
37.019 MDF; Jumper terminated correctly
38 UFB Fibre Flexibility Point (FFP)
-
38.001 Outer Door lock works smoothly and door closes without jamming
-
38.002 Door stays are in place and all work well
-
38.003 Cabling run correctly
-
38.004 Distribution Frame: Correct Trays installed
-
38.005 Distribution Frame: Drawer Labelling correct
-
38.006 Distribution Frame: Data card inside of drawer
-
38.008 All microducts earth terminated
-
38.009 All microduct earths labelled
-
38.01 All duct seals in place for cable entry
-
38.011 Concrete around ducts in base of cabinet
-
38.012 Locks & hinges OK
-
38.013 Door seals in good condition
-
38.016 Splitter installed
-
38.017 All unused connectors capped
-
38.018 Splitter leg parking bay
-
38.019 All micro ducts sealed
-
38.02 All micro ducts labelled
-
38.021 Fixed fibre strain relief installed
39 Aerial Terminal
-
39.001 Correct terminal used
-
39.002 Terminal mounted and secured correctly
-
39.003 Quiet Front terminal has sufficient gel
-
39.004 Terminal lid secure
-
39.005 Terminal label on lid or plate on pole
-
39.006 Lead-in entry correct
-
39.007 Lead-in terminated correctly
-
39.008 Plastic bag on multi-pair lead-in cable unused pairs
-
39.009 Cable shield installed
-
39.01 Non working pairs capped
-
39.011 Sufficient slack length
40 Pillar Terminal
-
40.002 Pillar ID correct
-
40.003 Lid secure
-
40.005 Plastic bags installed & secure
-
40.008 Coloured zip ties to 25 pair groups (not too tight)
-
40.009 Correct cable used
-
40.01 Correct connectors used
-
40.011 Circuit dedicated
-
40.012 Service Lead labelled correctly
-
40.013 Unused pairs capped
-
40.016 Encapsulated loop resealed correctly
-
40.017 V3: Lead-in customer and network labels OK
-
40.019 Service Lead - flying leads installed and correct
41 BDD Terminal
-
41.001 Pit lids secure/locked, with bung fitted where appropriate
-
41.002 Pit installed correctly
-
41.003 Radi: Base & lid clean, O ring seated correctly, O ring replaced upon entry
-
41.004 O/J lid labelled
-
41.005 Radi is correctly installed, thermal change and lead in
-
41.006 2m loops at BDD pits
-
41.007 2m insulated tail installed at last BDD
-
41.008 Plastic bags installed & secure
-
41.009 Coloured ties to 25 pair groups
-
41.01 Correct cable used
-
41.011 Correct connectors used
-
41.012 Circuit dedicated
-
41.013 Service Lead labelled correctly
-
41.014 Unused pairs capped
-
41.015 Damaged conductors repaired
-
41.016 Faulty connectors replaced
-
41.017 All cables, including lead-in cables, shall be zip-tied or taped together in a tidy loop within BDD pit.
-
41.018 Minimum sheath height 50mm
-
41.019 Service Lead - flying leads installed and correct
-
41.02 Unused pairs connected through
-
41.021 Green cable tie on exchange side
-
41.022 Connectors >50mm from ring cut
42 PDS Terminal
-
42.001 Pedestal - vertical, firm, depth
-
42.002 Correct size pedestal used
-
42.003 Lid secure
-
42.004 PDS network labelled correctly
-
42.006 QF terminal labelling correct
-
42.007 QF terminal secured to backing plate
-
42.008 Foam bung fitted
-
42.009 Adequate gel in quiet front
-
42.01 Service Leads installed correctly
-
42.011 Service Lead labelled correctly
-
42.012 Service Lead terminated correctly
-
42.013 Unused pairs capped
43 Aerial Service Lead
-
43.001 Correct Service Lead used
-
43.002 No In span joints
-
43.003 Tension, sag and twist correct
-
43.004 Correct pole fittings used and installed (screw eyes, sash clamps)
-
43.005 Lead-ins enter terminal correctly
-
43.006 White pipe down poles
-
43.007 600mm saddle spacing or 1500mm bandit spacing
-
43.008 Roadway crossing min 5.5m height, elsewhere 4.25 metre height
-
43.009 Loops on poles tied
-
43.01 Existing double "D" (OA501) or OA45 replaced if altered
-
43.011 Lightning protection runs >500 metres
-
43.012 Correct building fittings used (screw eyes, sash clamps)
-
43.013 Servi seal secured in upright position and Gel Snap secured horizontally
-
43.014 Unused pairs capped
44 Buried Service Lead
-
44.001 Service Lead terminated correctly
-
44.002 20mm pipe connected at Pedestal correctly - (bend into pedestal)
-
44.003 20mm pipe connected at BDD correctly (50mm into BDD pit, 450mm deep)
-
44.004 20mm pipe connected at RLG correctly (at base of DP, bend if room)
-
44.005 Individual pipe & cable for installs of <100 metre
-
44.006 Direct buried cable option (no pipe) for > 100 metre
-
44.007 Green 20mm installed in trench
-
44.008 White pipe above ground level
-
44.009 Depth correct (450mm cover)
-
44.01 Power/ Gas clearances correct
-
44.011 Cable & pipe repair correct
-
44.013 Pipe connected at ETP correctly (not glued)
-
44.014 Overlay of Service Lead justified
-
44.015 Service Lead labelled correctly
45 ETP
-
45.001 ETP physical alignment correct, all fittings secure, installation tidy
-
45.002 ETP location: (buried lead in-300-1500mm) (AE lead in on facia/under eaves)
-
45.003 ETP recessed (within cladding) location: 900-1500mm
-
45.004 Aerial lead in to ETP correct eg termination hardware, position, tidy appearance
-
45.005 20mm pipe to ETP is white only
-
45.006 20mm pipe end (within ETP) is sealed with silicone and drainage holes left clear
-
45.007 Premise cabling exit via back of ETP
-
45.008 Premise cabling exit from ETP is sealed with silicone
-
45.009 All connections via gel filled connectors
-
45.01 Protected ETP: Lightning arrestors fitted in areas that require protection
-
45.011 Protected ETP: Earth wire (6mm/green coating) 100mm min. bend radius observed
-
45.012 Protected ETP: Earth wire kept straight to Copper or Stainless Steel Earth rod
-
45.013 Protected ETP: Earth wire connection to earth rod with C-Lok product only
-
45.016 Unused pairs capped
-
45.017 Ericsson 5/NEG203200 ETP installed
-
45.017 Ericsson 5/NEG203200 ETP installed
-
45.018 ETP installed b/w 300mm & 1500mm above ground , secured with three screws, and installed to best suit the site and external cladding
-
45.019 locate wire installed , and terminated in ETP with redcaps (fixed fibre only)
-
40.020 FIbre building penetrations sealed
-
45.021 white pipe or flexi duct to outside of building is secured with plastic or galvanised saddles
-
45.022 50-20mm duct reducer fitted b/w 50mm underground green duct and 20mm above ground white pipe
-
45.023 fixed fibre or ABF tube housed in 20mm white pipe or UV stabilised flexi pipe where fibre exits through bottom of ETP
-
45.041 splitter installed correctly
46 Customer Premises
-
46.001 Correct cable used (cat 5 minimum - star wiring)
-
46.002 Correct pairs in cable used
-
46.003 Correct clearances observed
-
46.004 Wiring route acceptable and cable safe and secure
-
46.005 No under floor joints
-
46.006 Exposed surface wiring neat and tidy
-
46.007 Jack point hardware installed correctly
-
46.008 Jack points not installed in damp areas
-
46.009 Jack points at least 300mm above floor
-
46.01 2 wire jack system used
-
46.011 Installation date written inside jack point
-
46.012 Cable sheath clear of circuit board
-
46.013 CPE label installed
-
46.014 Contractor appearance/manner (customer view)
47 Business Premises
-
47.002 Equipment labelled and secured
48 0+2
-
48.001 Remote unit mounted correctly - BDD, Cust Prem, Cabinet
-
48.002 Remote unit mounted correctly on pole, or new pit
-
48.003 Pit installed correctly
-
48.004 Remote unit wired correctly
-
48.005 Records correct
49 Sales & Service Advice Note
-
49.001 Completion time and date filled in
-
49.002 Service Order number correct
-
49.003 Customer details correct
-
49.004 Service Required Details correct
-
49.005 Additional services provided are clearly recorded
-
49.006 Customer acknowedged with name and signature (or reason for no customer signature included)
-
49.007 S/O type correct
-
49.009 Service person name
-
49.01 Correct Billing Codes claimed
-
49.011 Phone / Circuit number correct
-
49.012 CSA correct
-
49.013 Network elements where work was carried out
-
49.015 Location service confirmed at
50 Exchange Complex Services
-
50.001 Card installed & configured
-
50.002 Levels adjusted to suit configuration & labelled
-
50.003 Alarms checked and correct
-
50.004 Equipment cover secure
53 TNT/TNF (Building Frames)
-
53.001 TNF or TNT installed correctly
-
53.002 Disconnection block installed correctly
-
53.003 Earthing requirements met
-
53.004 Demarcation point installed correctly
-
53.005 TNF/TNT Labelled correctly
-
53.006 TNT/TNF additional warning label installed NDF-151
-
53.007 Jumper routing via frame guides
-
53.008 Jumper type correct (OR/WH) with required slack left
-
53.009 Solder jumper terminations correct (wire strip & wrap, no excess solder)
-
53.01 Old jumpers removed
58 2 Meg
-
58.001 Job packs have all relivant information for the task in hand
-
58.002 Permits held, and show dates, timings and correct task codes
-
58.003 TLRD updated, integrity checked & confirmed
-
58.004 Fibre & bearer connectivity confirmed "end to end"
-
58.005 Spanline updated
-
58.006 ICMS updated
-
58.007 Traid updated
-
58.008 Control station advised of work completed
-
58.009 Commissioning information meets specified requirements
-
58.01 Correct DF jumper (5 wire) used
-
58.011 Jumper management correct with required (200mm) slack left
-
58.012 DF components secure & labelled
72.000 Reinstatement
-
72.001 property damage made good
-
72.003 Reinstatement / backfill satisfactory around buried service lead
-
72.007 Excess vegetation removed
73.000 SIte tidy
-
73.002 site tidy, no task waste - Cabinet internal
-
73.003 site tidy, no task waste - aerial terminal
-
73.004 site tidy, no task waste - pillar terminal
-
73.005 site tidy, no task waste - BDD terminal
-
73.006 site tidy, no task waste - PDS terminal
-
73.007 site tidy, no task waste - aerial service lead
-
73.008 site tidy, no task waste - buried service lead
-
73.009 site tidy, no task waste - ETP
-
73.010 site tidy, no task waste - customer premises
-
73.011 site tidy, no task waste - business premises
-
73.017 site tidy, no task waste - MDF
-
73.024 site tidy, no task waste - general