Information
-
Impoundment Name
-
Date
-
Inspector Name
-
Weather Condition
Water Impoundment/Access Road
-
Site ID Sign Permit?
-
Erosion & Sediment Control Plan present on site?
-
Is the access road in acceptable condition?
-
Is the location/road stable and free from accelerated erosion?
-
Are the culvert pipes/stream crossings open and functioning properly?
-
Is the location adequately vegetated (70% permanent ground cover)?
-
Is the location free of any fluid or gas leaks?
-
Is the location free of any fluid or gas contamination?
-
Is the location free of unused pipe, equipment, materials or debris?
-
Is the impoundment within 1,000 feet of an occupied structure?
-
Is the impoundment within city/town limits?
Erosion and Sediment Control
-
1. Surface Water Protection
-
Clean storm water runoff has been diverted from areas to be disturbed.
-
Bodies of water located either on site or in the vicinity of the site have been identified and protected.
-
Appropriate practices to protect on site or downstream surface water are installed.
-
2. Stabilized Construction Entrance
-
A temporary construction entrance to capture mud and debris from construction vehicles before they enter the public highway has been installed.
-
Other access areas (entrances, construction routes, equipment parking areas) are stabilized immediately with gravel or other cover as work takes place.
-
Sediment tracked onto public streets is removed or cleaned up on a regular basis.
-
3. Perimeter Sediment Controls
-
Silt fences are installed at appropriate spacing intervals.
-
Sediment/detention basins are installed.
-
Sediment traps and barriers are installed.
-
Silt fence material and installation comply with specifications.
Maintaining Water Quality
-
Is there an increase in turbidity causing a substantial visible contrast to natural conditions?
-
Are there any residual oil and floating substances, visible oil film, or globules or grease?
-
All disturbances are within the limits of the approved plans.
-
Have receiving surface waters/or wetlands been impacted by silt from the project?
Housekeeping
-
Is construction site litter and debris appropriately managed?
-
Are facilities and equipment necessary for implementation of erosion and sediment control in working order and/or properly maintained?
-
Is construction impacting the adjacent property?
-
Is dust adequately controlled?
Runoff Control Practices
-
1. Interceptor Dikes and Swales
-
Installed per plan with minimum side slopes 2H:1V or flatter?
-
Stabilized by geotextile fabric, seed or mulch with no erosion occurring?
-
Sediment laden runoff directed to sediment trapping structure?
-
2. Rock Outlet Protection
-
Installed per plan?
-
Installed concurrently with pipe installation?
-
Checked for sediment accumulation?
Soil Stabilization
-
1. Topsoil and Spoil Stockpiles
-
Stockpiles are stabilized with vegetation and or mulch?
-
Sediment control is installed at the toe of the slope?
-
Clean storm water runoff diverted from stockpile?
-
2. Re-vegetation
-
Minimum of topsoil has been applied under permanent seeding?
-
Temporary seeding and mulch have been applied to idle areas?
-
Estimated % of vegetation cover present.
Sediment Control Practices
-
1. Stabilized Construction Entrance
-
Stone is clean enough to effectively remove mud from vehicles?
-
Installed per standards and specifications?
-
Does all traffic use the stabilized entrance to enter and leave the site?
-
Is adequate drainage provided to prevent ponding at entrance?
-
2. Culverts
-
Installed at locations according to E&S Plan?
-
Outlet protection installed according to E&S Plan?
-
Checked for sediment accumulation?
-
3. Silt Fence
-
Installed on contour, 10' from toe of the slope (not across conveyance channels)?
-
Joints constructed by wrapping two ends together for continuous support?
-
Fabric buried per specifications (6 inches minimum)?
-
Posts are stable, fabric is tight, upright and without rips or frayed areas?
-
Estimated % of sediment accumulation per the design capacity.
-
4. Temporary Sediment Trap
-
Outlet structure is constructed per the approved plan or drawing?
-
Geotextile fabric has been placed beneath rock fill?
-
Sediment accumulation does not exceed designed accumulation elevation?
-
Estimated % of sediment accumulation pr the design capacity.
Please check ALL that apply
-
Construction of impoundment is complete.
-
Liner is installed.
-
No physical holes in liner.
-
Chain link fence is installed.
-
Orange safety fence is installed.
-
Slick wire is installed.
-
Gate(s) have locks in place.
-
Gate(s) are locked.
-
Life ring is installed.
-
Life ring is in the impoundment.
-
Impoundment has 2' freeboard (minimum).
-
Seed and mulch needs to be re-done.
-
Impoundment wall (fill) is not slipping.
-
Signs are on fence.
-
Pumps have containments.
-
Containments are empty.
-
Impoundment location clean (no trash/parts).
-
Additional Comments
-
Comments/Concerns: