Information
-
STORE NAME
-
BRAND
- WOOLWORTHS SUPERMARKET
- BIG W
- DAN MURPHY'S
- BWS
- COUNTDOWN SUPERMARKET
-
STORE / PROJECT NUMBER
-
PROJECT TYPE
- NEW STORE
- REFURBISHMENT
- EXTENSION
-
TYPE OF INSPECTION
- MECHANICAL - END OF WARRANTY DEFECTS
- MECHANICAL - WORKS COMPLETE DEFECTS
-
SITE ADDRESS
-
DATE CONDUCTED
-
PREPARED BY
Executive Summary
Executive Summary
-
Installed / Store Opening Date
-
Installing Contractor
-
Quality of Installation
- GOOD
- AVERAGE
- ADDITIONAL WORK REQUIRED
- POOR
-
Items requiring follow up
-
Detail of any interviews with store personnel
-
Detail of any recommendation.
-
Detail of any service issues
-
Add media
Asset Register
Asset Register
-
Main AHU
-
Cooling Coils
-
Condenser / Coil
-
Compressor
-
Controller
-
Bakery Exhaust Fan
-
Donut Exhaust Fan
-
Chicken Exhaust Fan
-
Staff Toilet Exhaust
-
Stock room exhaust
-
Smoke Spill and / or Smoke Exhaust
-
MSB Exhaust
-
ACU - 2
-
ACU - 3
-
ACU - 4
-
ACU - 5
Other item
-
Add media
Instruction Folder and As Builts
Instruction Folder and As Builts
-
Document Box Provided
-
Operation and Maintenance manual provided
-
Manuals provided in suitably labelled vinyl covered hard backed folder
-
Electrical wiring and control circuits included
-
Commission test detail included
-
Schedule of components included
-
Equipment operating procedures included
-
Stop Start and Fault reset procedures included
-
Plant Maintenance and Service Log Book provided
-
Confirm format suitable for both routine and preventative maintenance activities
-
Laminated 'as built' drawing affixed to plant room wall
-
All ductwork runs and equipment locations shown
Other item
-
Add media
Air handler
AHU
-
Adequate lighting provided to all compartments
-
Door Seals / Handles
-
Any noticeable air leaks
-
Magnahelic fitted / Working
-
Coil condition
-
Fire dampers tagged
-
Fire damper access
-
Economy cycle dampers working correctly
-
Internal insulation and lagging
-
Any water in chamber or on floor
-
Drains - Clear and Plumbed correctly
-
Any rust or corrosion
-
Outside & Return air dampers free of dirt / debris
-
All dampers correctly lubricated
-
Fan noise levels
-
Belt guards correctly fitted an secured
-
All access panels fitted & correctly secured
-
Any structural damage - supports, brackets etc
-
Any leaking roof penetrations
Other item
-
Add media
Refrigeration Plant
Refrigeration Plant
-
Compressor oil levels
-
Compressor noise levels
-
Compressor pump down efficiency
-
Correct operation of compressor capacity control
-
Coupling guards fitted / correctly secured
-
Refrigerant levels
-
Pressure gauges all operating correctly
-
Any pipe vibration present
-
Suction pipe insulation
-
Any missing service valve caps
-
Pipework installed in accordance with good refrigeration practices / manufacturers recommendations.
-
Pipework correctly secured and bracketed
-
Any rubbish or combustible materials within plant area
Other item
-
Add media
Switchboard / Controls
Switchboard / Controls
-
Any missing conduit covers
-
Any loose or dangerous wiring
-
All indicator lights working
-
Correct operation of contactors - overloads set correctly
-
Controller operating correctly
-
Stop / Start and fault reset procedure fixed to face of switchboard
Additional item
-
Add media
Heating
Heat Pump
-
Heat pump utilised
-
Coil condition
-
Confirm all fans working
-
Any corrosion
Additional item
-
Add media
Elements
-
Electric elements utilised
-
Confirm correct operation of all safety switches etc
-
Confirm correct operation of all elements
-
Confirm safe and easy access to elements
Additional item
-
Add media
Reclaim
-
Reclaim utilised
-
Coil condition
-
Confirm correct operation
Additional item
-
Add media
Boiler
-
Boiler utilised
-
Confirm correct operation of boiler
-
Confirm correct operation of water pump
-
Make up tank fitted - working correctly
Additional item
-
Add media
Condenser
Air Cooled Condenser
-
Air cooled condenser utilised
-
Coils clean and free of debris and dirt
-
Any coil damage
-
Confirm correct fan operation
-
Fan noise levels
Additional item
-
Add media
Cooling Tower / Evaporative Condenser
-
Cooling Tower or Evaporative condenser utilised
-
Any water leaks evident
-
Chemical dosing equipment working
-
Chemical stock on site
-
Chemical data sheets provided
-
Structural condition
-
Any corrosion evident
-
Surrounding area clean & tidy
Additional Item
-
Add media
Ducting & Ventilation
Air Distribution
-
Ducting Correctly Fastened /Secured
-
Condition of Duct Insulation
-
Any Sweating Ductwork
-
Registers installed correctly
-
Condition of Registers
-
Door Grilles Fitted where required
-
Correct Air Distribution
Additional Item
-
Add media
Ventilation
-
Confirm correct operation of stock room exhaust fan/s
-
Confirm Correct Operation of Plant Room Ventilation
-
Confirm Correct Operation of Toilet Exhaust Fan
-
Confirm correct operation of Chicken Hood Exhaust
-
Condition of Chicken Hood Filters
-
Confirm Correct Operation of Chicken Hood Make Up Air
-
Confirm Correct Operation of Bakery Hood Exhaust
-
Condition of Bakery Hood Filters
-
Confirm Correct Operation of Bakery Hood Make Up Air
-
Confirm Correct Operation of Donut Hood Exhaust
-
Condition of Donut Hood filters
Additional Item
-
Add media
Ancillary Plant
Ancillary Plant
-
Confirm correct operation of amenities A/C
-
Confirm correct operation of Cash Office A/C
-
Confirm correct operation of Systems Office A/C
-
Confirm correct operation of Managers Office A/C
-
Confirm correct operation of Training Room A/C
Additional item
-
Add media
Plant Access
-
Access on to roof
-
Safety ladders provided
-
Walk platforms provided
-
Harness fixing points provided where required
Performance Check
-
Ambient temperature - Deg C
-
Store trading area temperature - Deg C
-
Return air temperature - Deg C
-
Ambient RH - %
-
Store trading area RH - %
-
Evaporator air off temperature (cooling) - Deg C
-
Filter bank pressure drop - pa
-
Compressor 1 suction pressure - KPA (psi)
-
Compressor 1 oil pressure - KPA (psi)
-
Compressor 1 discharge pressure - KPA (psi)
-
Compressor 2 suction pressure - KPA (psi)
-
Compressor 2 oil pressure - KPA (psi)
-
Compressor 2 discharge pressure - KPI (psi)
-
Condenser air on temperature - Deg C
-
Condenser air off temperature - compressor 1 - Deg C
-
Condenser air off temperature - compressor 2 - Deg C
Sign Off
-
Add signature