Mech-Slip Rainscreen
-
Main Contractor: Bellway
-
Project Number: C1212 Riverwell, Watford
-
Issued to:
-
QA Sheet No:
-
Elevation:
-
Level:
-
Comments:
STRUCTURE and preceding trades
-
structure handed over
- Checked
- Hold
-
Personnel
- Installer
- A2O
-
Tyvek Firecurb Membrane
-
Correct membrane installed and sealed using the correct tape.
-
Personnel
- Installer
- A2O
-
Tears, splits or holes repaired and fully taped min 100mm overlap.
-
Personnel
- Installer
- A2O
Support Grid
-
Fixed and sliding point brackets spaced vertically/horizontally and fixing arrangement in accordance with working drawings using self rising chemical and threaded rod
-
Personnel
- Installer
- A2O
-
Vertical T and L rails positively fixed to fixed point brackets using Ejot JT4-6-5.5x22
-
Personnel
- Installer
- A2O
-
Vertical T and L rails fixed to sliding point brackets through slotted holes to facilitate movement.
-
Personnel
- Installer
- A2O
-
Horizontal movement joint included at slab level.
-
Personnel
- Installer
- A2O
Rockwool Insulation
-
Insulation fixed in accordance with A2O working drawings.
-
Personnel
- Installer
- A2O
-
Insulation joints and penetrations around brackets need to be butted tight with no gaps.
-
Personnel
- Installer
- A2O
ACS Brickslips
-
ACS Brickslip panels reference are installed according to the A2O drawings using the Ejot JT3 LT3 5.5x25 screws
-
Personnel
- Installer
- A2O
-
Make sure that ACS panels is interlock to each other as per manufacture specification.
-
Personnel
- Installer
- A2O
-
Check for cracked bricks and perps are plum and consistent
-
Personnel
- Installer
- A2O
Pointing
-
Check the mortar for the specification and correct color
-
Personal
-
check the pointing for any cracks
-
Personal
-
Installer Signature:
-
A2O Signature:
-
Client Signature: