Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Sabroe Compressor sets
-
Sabroe No.1<br>Model - SMC 8-108 <br>Operating Conditions<br>
-
Compressor No.1 - Duty selection
-
Compressor No.1 - Run Hours
-
Add media
-
Sabroe No.2<br>Model - SMC 8-108 <br>Operating Conditions<br>
-
Compressor No.2 - Duty selection
-
Compressor No.2 - Run Hours
-
Add media
-
Sabroe No.3<br>Model - SMC 8-108 <br>Operating Conditions<br>
-
Compressor No.3 - Duty selection
-
Compressor No.3 - Run Hours
-
Add media
-
Recommendations or issues
Vessels
-
HP Liquid Receiver operating conditions
-
HP Liquid Receiver level
-
Is the HP Liquid Receiver level being maintained to within control range. Tick for yes
-
Visually check all Shut off, Hand Regulation and Pressure relief valves. Tick for complete
-
IP Receiver operating conditions
-
IP Receiver level
-
Is the IP Receiver level being maintained to within control range. Tick for yes
-
Visually check all Shut off, Hand Regulation and Pressure relief valves. Tick for complete
-
Visually check all Shut off, Hand Regulation and Pressure relief valves. Tick for complete
-
Add media
-
LP Receiver operating conditions
-
LP Receiver level
-
Is the LP Receiver level being maintained to within control range. Tick for yes
-
Visually check all Shut off, Hand Regulation and Pressure relief valves. Tick for complete
-
Add media
-
LP Liquid Pumps operating conditions
-
Check and record Liquid pump running pressure
-
Visually check Liquid Pump Shut off valves, Minimum Flow Line, and ice Build up. Tick for complete
-
Add media
-
Oil Rectifier conditions
-
Has Oil been drained from the Oil Rectifier. Tick for yes
-
If Yes... How much oil has been drained
-
Add media
-
Recommendations or issues
Cooling Tower
-
Cooling Tower - Running Conditions
-
Cooling Tower - Run Hours
-
Are the Cooling Tower fans operating correctly. Tick for yes
-
Check All Fan V-belts, Fly wheels and Pulleys etc,Tick for complete
-
Are the cooling Tower Water Circulation Pumps operating correctly. Tick for yes
-
Check the Cooling Towers for any water leaks. Tick for complete
-
Is the cooling tower water treatment system functional. Tick for yes
-
Add media
-
Recommendations or issues
Compressor Cylinder heads & oil cooling system
-
Circulation Pump Running Conditions
-
Is the flow and return pressure operating within control range. Tick for yes
-
Is the temperature stable and being maintained to control range. Tick for yes
-
Flow Temperature
-
Return Temperature
-
Flow Pressure
-
Return Pressure
-
Add media
-
Recommendations or issues
Electrical & Controls
-
PLC and control wiring condition
-
HMI / SCADA Condition
-
Cooling Tower Switchgear / VSD / Soft Starter Condition and operation
-
Evaporator fans, Switchgear / VSD / Soft starter Condition and operation
-
Sabroe compressor Motor - Switchgear / VSD / Soft Starter Condition and Operation
-
Has a Visual inspection of ALL switch gear and cables been carried out ? Tick for yes
-
Check the operation of the plantroom exhaust fan, Tick for complete
-
Add media
-
Ammonia detection system - Condition and Operation
-
Check the PPM readings on the Ammonia detection system, Tick for complete
-
Add media
-
Recommendations or issues
Coldstore No.1
-
Room running conditions
-
Water defrost or Hot gas circuit operating correctly, Tick for yes
-
Room temperature achieving correct setpoint, Tick for yes
-
Check the fans are operating correctly and check the fan blades, Tick for complete
-
Check the coil is clear of ice, Tick for yes
-
Check the drains are clear, Tick for yes
-
Add media
-
Recommendations or issues
Coldstore No.2
-
Room running conditions
-
Water defrost OR Hot Gas circuit operating correctly, Tick for yes
-
Room temperature achieving correct setpoint. Tick for yes
-
Check the fans are operating correctly and check the fan blades, Tick for yes
-
Check the coil is clear of ice,Tick for yes
-
Check the drains are clear, Tick for yes
-
Add media
-
Recommendations or issues
Coldstore No.3
-
Room running conditions
-
Water defrost OR Hot gas circuit operating correctly, Tick for yes
-
Room temperature achieving correct setpoint
-
Check the fans are operating correctly and check the fan blades, Tick for yes
-
Check the coil is clear of ice, Tick for yes
-
Check the drains are clear, Tick for yes
-
Add media
-
Recommendations or issues
General Site Health & Safety / Miscellaneous
-
Recommendations or issues
-
Is a Quotation Required. Tick for yes
-
Provide details.....
-
Add media
-
Technician's signature