Title Page
-
Conducted on
-
Site conducted
-
Prepared by
-
This Inspection is based on the 29 Hazards from the Housing Health and Safety Rating System as well as the relevant Statutory Compliance listed below.
-
The relevant Primary Legislation for HMO'S , Shared House's and Single Let Assured Shorthold Tenancies (AST's) is Section 3 of the Health and Safety at Work Act 1974 (to be applied only in communal areas) and the Housing Act 2004.
-
The relevant Secondary Legislation for HMO's and Shared Houses is The Management of Houses in Multiple Occupation (England) Regulations 2006 .
Occupants
Occupant Management
-
Does each occupant have an in-date individual risk assessment on Inform?
-
Have all necessary risk and control measures been identified and implemented?
-
Have any necessary Personal Emergency Evacuation Plans been completed?
-
Is there an Emergency Evacuation Plan in place for the property?
Statutory Compliance
Property Type
-
House, Flat or Office?
-
Is the property shared and if so who with? I.e. Other employing organisation/s or tenants not in connection with Julian House.
-
What is the age of the property?
Compliance Records
-
Has Portable Appliance Testing (PAT) been carried out in the last 2 years or 4 years for offices?
-
Has the gas safe inspection been carried out within the last year?
-
Have defects identified on the certificate been rectified?
-
Has the fixed electrical wiring test been carried out within the last 5 years?
-
Have C1 or C2 recommendations been completed?
-
Has the emergency lighting been inspected in the last year?
-
Have the fire extinguishers been inspected within the last year?
Local Safety Checks
-
Are portable extinguishers being checked over on a weekly basis?
-
Is the emergency lighting being tested every month?
-
Is the fire alarm system/smoke detection being tested on a weekly basis?
-
Are the monthly safety checks being carried out consistently?
-
Are issues or concerns raised being dealt with in a timely manner?
-
Is a fire drill being carried out every 6 months?
-
Have any concerns such as extended evacuation time or do not evacuates been rectified?
HMO Licensing
-
Principal Legislation: The Management of Houses in Multiple Occupation (England) Regulations 2006
-
Is the property classed as a Housing in Multiple Occupation (HMO)?
-
What type of HMO is the property?
- Licensable
- Non-Licensable
- Non-Licensable (Registered Social Landlord exemption)
-
When does the HMO License expire?
-
Is the HMO License displayed?
-
Are the Property Manager's details displayed in a prominent position in the HMO?
-
This must include the Property Manager's name, office address and phone number.
Fire Safety
-
Primary Legislation: The Housing Act 2004.
Fire Risk Assessment
-
Is there a valid Fire Risk Assessment in place?
-
When was the Fire Risk Assessment last reviewed?
-
Who conducted the Fire Risk Assessment?
-
Have all fire safety actions from the Fire Risk Assessment been completed?
Fire Detection
-
Is there an appropriate Automatic Fire Detection and Alarm System in place?
-
What grade is the system?
-
What level of coverage does the system provide?
- LD1 (installed to all areas that form escape routes and in all rooms and areas other than those with negligible sources of ignition such as bathrooms)
- LD2 (installed throughout all escape routes and in all specified rooms or areas that present a high fire risk to occupants including kitchen and principal habitable room)
- LD3 (installed throughout all escape routes such as hallway and landing)
-
Is the level of coverage appropriate?
-
Are there obvious defects/health and safety concerns?
Emergency Routes and Exits
-
Are all means of escape free from obstruction?
-
Are all means of escape in good repair and working order?
-
Are there obvious defects/health and safety concerns?
Hazard Profiles
Damp and Mould Growth
-
Are there any concerns regarding dust mites, damp or mould growth?
-
Is there good ventilation throughout the property?
-
Do the occupants have the ability to control the temperature inside the property?
-
Are there obvious defects/health and safety concerns?
Excess Cold and Heat
-
Are there any significant changes in temperature during different times of the year?
-
Are the occupants comfortable with the temperature?
-
Are there any concerns about excessive cold or heat in the property?
-
Are there obvious defects/health and safety concerns?
Asbestos and Manufactured Mineral Fibres
-
Has an asbestos management survey been obtained for the property?
-
Have any recommendations for removal been completed?
-
If ACMs or presumed ACMs have been left in place, is there a written record or register available at the property which has been reviewed within the last 6-12 months?
-
Are there obvious defects/health and safety concerns?
Biocides and Control of Substances Hazardous to Health (COSHH)
-
Are there any signs that timber or mould growth has been treated with a biocide?
-
Are hazardous substances including cleaning products adequately labelled and stored away properly with the COSHH assessment/s when not in use?
-
Are there obvious defects/health and safety concerns?
Carbon Monoxide and Fuel Combustion Products
-
Is there carbon monoxide alarm located near each fuel burning appliance? (excluding gas cookers)
-
Are there obvious defects/health and safety concerns?
Lead
-
Is any plumbing pipework in the property a dull grey colour?
-
Is there an existing paint coating in the property built before the 1980s?
-
Has the old paintwork been painted over?
-
Is there damage and/or flaking of the old paintwork?
-
Are radiators and associated pipe work free from rust, damage or missing paint?
-
Are there obvious defects/health and safety concerns?
Radiation
-
Has the property been checked against the UK Radon Interactive Map?
-
What is the maximum radon potential?
- Less than 1%
- 1-3%
- 3-5%
- 5-10%
- 10-30%
- Greater than 30%
-
Has a radon risk report been obtained if above the 3% action level?
-
If the radon risk report determines a high level of radon, has a radon measurement of the property been taken?
-
Is the suitable remedial method advised by the UK Health Security Agency being carried out?
-
Are there obvious defects/health and safety concerns?
Uncombusted Fuel Gas
-
Have occupants ever smelt gas in the property?
-
Does the gas cooker and hob including the control knobs appear to be in good condition?
-
Does the fireplace appear to be in good condition?
-
Is LPG being kept inside anywhere on the premises?
-
Are there obvious defects/health and safety concerns?
Volatile Organic Compounds
-
Has any new furniture been ventilated?
-
Are there obvious defects/health and safety concerns?
Crowding and Space
-
Is the occupancy limited to one person per bedroom?
-
Are there adequate facilities for the occupants? (kitchen, bathroom and communal space)
-
Is the recreational space safely fenced off?
-
Are there obvious defects/health and safety concerns?
Entry by Intruders
-
Do all doors and windows lock and function as they should?
-
Does the front door have a good, secure lock?
-
Is there adequate external lighting which gives good coverage and reduces shadows up to entry points to the property?
-
Does the property have CCTV?
-
Do the occupants have any concerns regarding security?
-
Are there obvious defects/health and safety concerns?
Internal Lighting
-
Can the lighting be controlled by the occupants?
-
Is the lighting of a comfortable brightness and free from flicker?
-
Is there any broken/burned out lighting?
-
Is the lighting throughout the property sufficient to work and move about safely?
-
Do the occupants have any concerns regarding the lighting at the property?
-
Are there obvious defects/health and safety concerns?
Noise
-
Is the area surrounding the property particularly noisy?
-
Is there any noisy equipment or facilities including plumbing?
-
Is there continuous noise?
-
Have the occupants raised any concerns regarding noise?
-
Are there obvious defects/health and safety concerns?
Domestic Hygiene, Pests and Refuse
-
Is there a clean, functioning waste bin in the area which is used for appropriate waste?
-
Is there a domestic waste bin available in the kitchen which is not overfilled and in good condition?
-
Is there any evidence of vermin/pests such as droppings, ammonia-like smell or gnaw marks?
-
Have any of the occupants raised concerns regarding vermin/pests?
-
Are there obvious defects/health and safety concerns?
Food Safety
-
Are there adequate and suitable food storage facilities including power socket outlets provided?
-
Are there adequate cooking facilities provided?
-
Is there adequate space for food preparation?
-
Are sinks, draining boards and work tops properly installed and fitted including being sealed to adjacent surfaces and provided with splash-backs?
-
Are there obvious defects/health and safety concerns?
Personal Hygiene, Sanitation and Drainage
-
Are there adequate and suitable washing facilities available? (for personal hygiene, clothes and cooking equipment)
-
Are the washing facilities present of a good standard?
-
Are there enough toilets and bathrooms available for the number of occupants?
-
Are the drainage facilities adequate?
-
Has anyone raised any concerns regarding hygiene, sanitation or drainage?
-
Are there obvious defects/health and safety concerns?
Water Supply
-
Has a legionella risk assessment been carried out?
-
Have recommendations from the legionella risk assessment been completed?
-
Are appropriate measures being carried out to control and manage legionella bacterium?
-
Are there obvious defects/health and safety concerns?
Falls Associated with Baths/Showers
-
Are baths and/or showers stable and securely fitted?
-
Are safety features in the bathroom incorporated such as handles or grab rails?
-
Is there sufficient functional space in the bathroom to enable occupants to dress, undress and dry themselves?
-
Have all baths or showers had anti-slip mats or anti-slip flooring installed around them?
-
Do occupants with mobility issues have a Falls Risk Assessment?
-
Has anyone raised any concerns regarding slips associated with baths?
-
Are there obvious defects/health and safety concerns?
Falls on Level Surfaces
-
Is there a properly constructed floor, path or yard where needed?
-
Are there any loose paving stones, uneven surfaces and/or overgrown land on the grounds?
-
Are there any slippery or icy conditions?
-
Are all carpets and floor coverings inside the property in good condition and free from disrepair?
-
Are all carpets and floor coverings inside the property fitted tightly preventing slippage or bunching?
-
Are all trailing cables kept to a minimum and away from walk areas?
-
Are all walk areas kept clear of obstructions?
-
Are personal belongings kept off of the floor and stored responsibly away from main traffic routes?
-
Has anyone raised any concerns regarding slips, trips and falls on level surfaces?
-
Are there obvious defects/health and safety concerns?
Falls Associated with Stairs and Ramps
-
Are there bannisters lining each staircase?
-
Are all bannisters and/or handrails secure and free from signs of damage?
-
Are floor coverings across stairs and ramps well fastened, in good condition and free from disrepair?
-
Are there obvious defects/health and safety concerns?
Falls between Levels
-
If there is an attic, is it locked?
-
Do any windows open below waist height?
-
For windows above ground floor level, are restrictors fitted to limit window opening to 100mm in place?
-
Does the property have a balcony?
-
Is it adequately protected with a guarding greater than 1,100mm in height?
-
Is the guarding greater than 1,100mm in height?
-
Is the guarding of solid construction and secure?
-
Could the guarding be easily climbed?
-
Are there openings in the guarding that open greater than 100mm?
-
Are there obvious defects/health and safety concerns?
Electrical Hazards
-
Do all electrical sockets operate normally?
-
Are all electrical sockets and cables free from visible damage?
-
Are there any signs of overheating or arcing visible on the socket such as browning of the plastic around the socket holes?
-
Is a plug-in Residual Current Device (RCD) adapter used when there is concern with using an occupant's electrical equipment or where leads are used outside?
-
Are there obvious defects/health and safety concerns?
Fire
-
Has a fire risk assessment been completed or reviewed in the last 12 months?
-
Have all fire safety actions been completed?
-
Is there any disrepair to the fabric of walls or ceilings?
-
Are internal doors made of solid construction and free from damage?
-
Do all doors close fully shut into the door frame when released from the open position?
-
Has the fire blanket in the kitchen been formally inspected in the last 12 months?
-
Is the fire blanket stored in its protective pouch and fixed to the wall in the kitchen?
-
Is the fire blanket protective pouch within 1-2 metres of the cooker and fixed between the cooker and the nearest exit?
-
Is a portable convector heater being used anywhere within the property?
-
Are fire doors being propped or wedged open?
-
Are fire exits and escape routes being kept clear at all times?
-
Is the fire alarm panel fault-free?
-
If fire extinguishers are provided, are they free from damage? I.e. Safety pins intact, gauges in the green and hoses/horns in place?
-
Are there any concerns regarding fire safety?
-
Are there obvious defects/health and safety concerns?
Flames, Hot Surfaces and Materials
-
Are all hot water outlets set at a reasonable temperature?
-
Are all hot water outlets labelled?
-
Are all hot surfaces labelled?
-
Are hot surfaces such as hot water pipes covered where they present a risk of burns?
-
Has anyone raised any concerns about burns or scalding?
-
Are there obvious defects/health and safety concerns?
Collision and Entrapment
-
Do all door self-closing devices operate in a smooth and timely manner?
-
Is the glazing in a door, low window or other vulnerable location made of safety glass?
-
Is there disrepair to windows, frames and/or window furniture?
-
Is there low head room to doors well under 1.9 metres?
-
Are there low beams and ceilings well under 1.9 metres?
-
Are there gaps of over 60mm between the end of a bed rail and headboard?
-
Are there gaps of over 120mm from any accessible opening between the bed rail and the mattress platform?
-
Are there unprotected gaps of over 100mm in bannisters?
-
Are there obvious defects/health and safety concerns?
Explosions
-
Does the property have a mains gas supply?
-
Are there any obvious ignition sources close to gas appliances?
-
Has anyone raised any concern regarding explosions?
-
Are there obvious defects/health and safety concerns?
Ergonomics
-
Can all the amenities be used with ease? I.e. Storage of heavy items being kept in lower level cupboards, shelving etc and appropriate siting of electric switches.
-
Has anyone raised any concerns about ergonomics or the layout of the property?
-
Are there obvious defects/health and safety concerns?
Structural Collapse and Falling Elements
-
Is all guttering including rainwater goods secure?
-
Is there anything overhanging from the roof such as bird spikes, gutter brushes, roof tiles and so forth?
-
Does there appear to be any drainage or flooding issues?
-
Are there any loose fittings or fixtures such as lights, cupboards or shelves?
-
Are there any maintenance issues that could affect health and safety?
-
Are there any concerns regarding structural integrity?
-
Are there obvious defects/health and safety concerns?