Information

  • Audit Title

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

1.0 - Previous inspection

  • 1.1 - Has the last inspection been reviewed?

  • 1.2 - Are there no outstanding actions?

2.0 - General SHEQ requirements

  • 2.1 - Is the SHEQ policy displayed in reception and on notice board?

  • 2.2 - Is the SHE file up today?

  • 2.3 - When last was a SHE meeting held? Check minutes.

  • 2.4 - Is there proof of inductions done?

  • 2.5 - Is the SHE team appointed and trained?

  • 2.6 - Does the branch have a training plan?

  • 2.7 - Is there proof of training received / given (including coaching or on the job training)?

  • 2.8 - Is the current letter off Goodstanding displayed?

  • 2.9 - Is SHE inspections current and kept on file?

  • 2.10 -Is tool box talks done regularly?

  • 2.11 - Is there a PPE issue register?

3.0 - Fire Prevention

  • 3.1 -Evacuation plan displayed and understood by all employees?

  • 3.2 - Evacuation procedures discussed regularly? (3 to 4 times a year)

  • 3.3 - Extinguishers in place, clearly marked for type of fire?

  • 3.4 - Extinguishers recently serviced? (Check 6 monthly punch mark on tabs.)

  • 3.5 - Extinguishers clear of obstructions?

  • 3.6 - Adequate direction notices for fire exits?

  • 3.7 - Exit doors easily opened from inside?

  • 3.8 - Exits clear of obstructions?

  • 3.9 - Fire alarm system functioning correctly?

4.0 - General Lighting

  • 4.1 - Good natural lighting?

  • 4.2 - Reflected light from walls & ceilings not causing glare to employees?

  • 4.3 - Light fittings clean and in good condition?

5.0 - Compressors and welding equipment

  • 5.1 - Is there a guard on the working parts of the compressor?

  • 5.2 - Is there a test certificate for the compressor?

  • 5.3 - Is the manufacturers data plate displayed on the compressor

  • 5.4 - Are the gauges in good working order and not damaged?

  • 5.5 - Does the gauges indicate the maximum SWP line?

  • 5.6 - Is pressure release valves fitted and sealed?

  • 5.7 - No hoses / pipes damaged at compressor or on oxy/acetylene bottles

  • 5.8 - Is the correct PPE supplied at the welding bay? Is it u damaged

  • 5.9 - Is the bottles stored in the correct way?

  • 5.10 - Is flashback arresters fitted?

  • 5.11 - Is the welding machine functional and undamaged?

  • 5.12 - Is the electrode holder and earth cables undamaged?

6.0 - Rubbish Removal

  • 6.1 - Bins located at suitable points around site?

  • 6.2 - Bins emptied regularly?

  • 6.3 - Oily rags and combustible refuse in marked containers?

  • 6.4 - Is there certificates of safe disposal for contaminated waste?

  • 6.5.- Does the branch recycle?

7.0 - Parts Department (storage)

  • 7.1 - Materials stored in racks and bins wherever possible?

  • 7.2 - Storage designed to minimise lifting problems?

  • 7.3 - Floors around racking clear of rubbish?

  • 7.4 - General condition of racks and pallets?

  • 7.5 - Does racking and shelving display permissible stack weight?

8.0 - Workshop area (including washbbay)

  • 8.1 - Is the workshop kept clean? (General overall impression)

  • 8.2 - Is work areas demarcated?

  • 8.3. - Is work areas kept neat and tidy? No tripping hazards?

  • 8.4 - What is the general conditions of tools at work benches?

  • 8.5 - Is there any defective electrical tools?

  • 8.6 - Drip pans provided floor to prevent spillage?

  • 8.7 - Adequate work space?

  • 8.8 - Is lighting adequate?

  • 8.9 - Noise levels controlled?

  • 8.10 - Are LPG gas bottles secured and stored safely?

  • 8.11 - Is the walkways clearly marked and free from obstructions?

  • 8.12 - How is the general housekeeping at the washbbay area?

  • 8.13 - Is the hoses stored neatly when not in use?

  • 8.14 Is the drainage clean?

  • 8.15 - Is the lightning adequate?

  • 8.16 - Is certificates of compliance available for special tools?

9.0 - Electrical Safety

  • 9.1 - Safety switches installed?

  • 9.2 - Safety switches tested every 6 months and tests recorded?

  • 9.3 - No double adapters in use?

  • 9.4 - No broken plugs, sockets or switches?

  • 9.5 - No power leads across walkways?

  • 9.6 - No frayed or damaged leads?

  • 9.7 - Portable power tools in good condition?

  • 9.8 - Where required are emergency shut-down procedures in place?

10.0 - Chemical Safety

  • 10.1 - Hazardous Substance Register complete and available?

  • 10.2 - Material Safety Data Sheets available for all chemicals?

  • 10.3 - Risk assessments completed for hazardous substances?

  • 10.4 - Do special storage conditions apply?

  • 10.5 - If applicable are special storage conditions followed?

  • 10.6 - If required is PPE available?

11.0 Ladders

  • 11.1 - Are all ladders Industrial strength? (Non Household rated, check label.)

  • 11.2 - Are ladders in good condition?

  • 11.3 - If used for electrical work are they non conductive? (Wood or fibre glass.)

  • 11.4 - Are ladders numbered and inspected? (Check inspection sheets)

12.0 - First Aid Facilities

  • 12.1 - Are cabinets and contents clean and orderly?

  • 12.2 - Are contents regularly checked?

  • 12.3 - No contents past their expiry date?

  • 12.4 - Cabinets clearly labelled?

  • 12.5 - Is there easy access to cabinets?

  • 12.6 - Employees aware of location of first aid cabinet?

  • 12.7 - Are first aid officers accessible?

  • 12.8 - Are emergency numbers displayed?

13.0 - Office Hazards

  • 13.1 - Condition of filing cabinets?

  • 13.2 - Condition of chairs? (Five star bases.)

  • 13.3 - Desks in good condition? (No damage.)

  • 13.4 - Screen Based Equipment positioned to reduce glare from windows etc?

  • 13.6 - Tasks designed to prevent Occupational Overuse Syndrome? (Breaks included.)

  • 13.7 - Air conditioning systems regularly maintained?

  • 13.8 - Stable non-slip floor coverings in good condition?

14.0 - Vehicle Condition and requirements:

  • 14.1 - Schedule maintenance performed?

  • 14.2 - Condition of tyres?

  • 14.3 - Brake performance?

  • 14.4 - Lights? (Check operation of brake, indicator and reversing lights)

  • 14.5 - Condition of seats?

  • 14.6 - What is the general conditions of the vehicle? Any damages to bodywork or branding?

  • 14.7 - First aid kit supplied and adequate?

  • 14.8 - Is the vehicle neat and tidy inside?

  • 14.9 - Are all containers in vehicle marked?

  • 14.10 - Is there proof of spillages in vehicle?

  • 14.11 - Electrical tools in vehicle safe and undamaged?

  • 14.12 - Is hand tools in vehicle safe and undamaged?

  • 14.13 - Is their MSDS sheets in the vehicle for chemicals carried?

  • 14.14 - Is weekly / monthly inspections done? Check records.

15.0 - Security

  • 15.1 - Is the outside of the building kept neat and tidy?

  • 15.2 - What is the conditions of the guardhouse?

  • 15.3 - Is the OB book signed regularly?

  • 15.4 - Is the guard dressed in the prescribed uniform?

16.0 - Ablution fiscilities

  • 16.1 - Is daily inspections done?

  • 16.2 - Has a deep clean been done in the change rooms?

  • 16.3 - Are all the lights in working order?

  • 16.4 - Is plumbing in good working order?

  • 16.5 - General housekeeping of areas?

17.0 - Kitchen / Canteen

  • 17.1 - Is daily inspections being done?

  • 17.2 - Is fridge clean? Defrosted?

  • 17.3 - Is the microwave clean?

  • 17.4 - Is adequate seating provided? Is it safe?

  • 17.5 - Is bins provided for waste?

Sign Off

  • On site representative

  • Auditor's signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.