Title Page

  • Conducted on

  • Prepared by

  • Location

BUILDING REQUIREMENTS AND DOCUMENTATION

  • Occupancy Certificate kept on site and available for inspection by an Approved Inspection Authority (SANS 10400 Part A 15, B)

  • All permits and certificates of compliance required are up to date and kept on file and are available for inspection by an Approved Inspection Authority

  • A set of approved building plans available onsite at all times

  • Inspections are done by a competent person at least once every six months for the first 5 years and there after every year to render the structure safe for continued use (SANS 10400 Part A15)

  • Preventative maintenance of building and fixtures (National Building Regulations and Building Standards Act No,103 A15)

  • Planned maintenance schedule/program and record kept of inspections and maintenance done (National Building Regulations and Building Standards Act No,103 A15)

  • Business continuity plan (Nice to have)

  • Condition of rooms and facilities kept in a clean, hygienic, safe, whole and leakfree condition, and in a good state of repair (OHS Act Sec. 8 (2); FR 9; SANS 10400 A15)

  • HVAC Quarterly inspections and annual servicing and ensure inspection and servicing records are available on request (OHS Act Sec. 8; SANS 10400 Part O; DMR 15 & EMR 18)

  • HVAC Ensure that the area is ventilated (SANS 10400 Part O)

  • OHS Policy signed by CEO displayed (OHS Act Section 7)

  • Baseline Safety, Health and Environmental Risk Assessment (OHS Act & Construction Regulations 9)

  • POPI Policy displayed (Protection of Personal Information Act (POPI), Act 4 of 2013)

  • Pest control (on a quarterly to monthly basis depending on their needs)

  • Anchor bolts load tested (every 6 months)

  • Split units serviced regularly and in good working order

  • Lifts tests carried out by a registered lift inspector (Lift, Escalator and Passenger Conveyor Regulations, 1994 & SANS 15451:2016)

  • Gas suppression system

EMERGENCY ORGANISATIONAL PLAN

  • Emergency Evacuation Plan available and displayed in all common areas as per requirements

  • The orientation of the plan as displayed shall be related to the viewer so that locations on the left of the plan are to the viewer's left and locations on the right of the plan are to the viewer's right

  • All symbols meet EN701 and reflect those that are currently in use within the building

  • The reader’s location is identified with a clear "You Are Here" which works in conjunction with the plan's orientation

  • Floor plans follow a consistent standard in design and colour, focussing on simplicity

  • A site plan provides an overview of the building, its surroundings and location of assembly point

  • A simple to follow legend for the symbols

  • Plans identified with a reference, creation date and author details

  • Plans checked on a regular basis to ensure they remain accurate

  • Actions to be taken in the event of a fire or other emergency and method of raising the alarm are displayed

  • Emergency Assembly Point

  • Appointed Fire Marshal for each building/area

  • Competency/Training Certificate available for each Fire Marshal

  • 6 monthly fire drills conducted

  • Emergency Evacuation Signage SABS Approved/Photo luminescent

  • Emergency Evacuation Signage Persons with Disability, are taken into account: Position: 1.4 – 1.7 m from floor level when wall mounted. Position: 2.4 m from floor level when hanging from the ceiling

  • Sufficient Emergency Evacuation Signage Visible from all angles

  • Emergency Evacuation Signage EXIT sign above each Emergency Exit door

  • Emergency escape doors to open outwards

  • Emergency exits and routes not obstructed (Environmental Regulation for Workplaces 9(1)(b) OHS Act 85 of 1993

  • Emergency staircases and steps from one floor to another provided with handrails

  • Emergency staircases to be of a width and of a gradient which will facilitate the quick and safe egress of the number of persons to utilize

  • Emergency staircase wheelchair lifts available for the disabled

  • Emergency lighting is always kept in a good state of repair

  • Illumination survey conducted?

  • Testing of emergency lighting to be conducted at a period not exceeding three months

  • First aid box available (General Safety Regulations 3)

  • Signage to indicate the location of the first aid box

  • Contents to conform to GSR 3 annexure

  • Name of responsible person to be displayed on the first aid box

  • OHS Act General Safety Regulations 3

  • Documentation to be available in the first aid box Dressing Register – to record incident history and GSR 3 Annexure – minimum contents list

  • Monthly inspections to be conducted and recorded on a checklist

  • OHS Act General Safety Regulations 3

  • Indicate the location of the first aid boxes on the floor plan (Evacuation Diagrams)

  • AED

FIRE EXTINGUISHERS SANS10400 SECTION T

  • Easily accessible and unobstructed

  • Wall mounted not higher than 1,5m and not lower than 30mm from floor level

  • Distribution of fire extinguisher 1/400m²

  • Fire extinguishers types acceptable: Water9L/Foam9L/Carbon Dioxide5kg/Dry Chemical Powder4,5kg

  • Fire Extinguisher Cabinet Key to be available

  • Monthly Checklist

  • Appointed Fire Marshal

  • Appointed Fire Extinguisher Inspector

  • Serviced Annually Servicing company to provide a profile with SANS registration certificate and the technicians SAQCC registration certificate – Registration certificates to be kept on file

  • Fire Extinguisher Training conducted with all staff / included in induction training

  • Appropriate signage to indicate the location of firefighting equipment, signage to be visible from all angles (Photo luminescent)

FIRE HOSE REELS SANS10400 SECTION T

  • Annually serviced

  • Unobstructed

  • Flow and pressure tested at least 300kPA 1200liter per minute

  • Not to be used for other purposes (like washing cars or mixing mortar)

FIRE HYDRANTS SANS10400 SECTION T

  • Annually serviced

  • Pressure tested

  • Pump room in good/clean condition

  • Maintenance

FIRE DETECTION SYSTEM CONTROL PANEL SANS 10139:2012 Part 12

  • Logbook for fire alarm notifications (Services must be recorded and faults, changes and updates listed in a logbook)

  • Easily accessible location and preferably monitored 24/7

  • Fire panel weekly check to ensure no fault notification

  • Annually serviced (service records to be available)

  • Smoke detectors tested (Fire alarm systems should be visually inspected for damage or errors daily and serviced by an accredited fire alarm installer every six months to stay compliant to regulations and building insurance requirements)

  • Check that smoke detectors has not been tampered with

MANAGEMENT CONTROL

  • Contractor Management Procedure

  • Risk assessment provided for construction or hazardous work (working at heights, welding, electrical, cutting etc.)

  • Is there a signed OHS Act Contractors Agreement & site rules in terms of Sec 37 (2)

  • Letters of Good Standing: All independent contractors to submit current letters from Compensation Commissioner or licensed compensation Insurer/agent (FEM/RMA, etc.)

  • Server room (limited access to authorized personnel only, security measures such as access controls, security badges, and surveillance cameras, controlled environment with proper temperature and humidity levels to prevent overheating and equipment damage)

  • Housekeeping

  • Waste Management

  • All hazardous waste (Sludge /used oil/waste thinners/ batteries/bulbs, etc. removed from the premises must generate a disposal certificate from a registered Disposal Contractor)

  • Smoking Controls no smoking in building (FR 6, SANS 10400 Part O & Section 3 of Tobacco Products Control Act, 1993)

  • Designated Smoking Area (FR 6, SANS 10400 Part O & Section 3 (b); 6 & 7 of Tobacco Products Control Act, 1994)

  • No smoking signage in areas where smoking is not allowed (FR 6, SANS 10400 Part O & Section 3 of Tobacco Products Control Act, 1995)

  • Smoking Policy Statement (FR 6, SANS 10400 Part O & Section 3 of Tobacco Products Control Act, 1996)

FACILITIES

  • Toilets and Hand washing/drying (SANS 10400F; Facilities Regulations 2)

  • Sufficient male/female facilities (Facilities Regulations 4)

  • Toilet facilities in a hygienic leak free condition (Facilities Regulations 2)

  • Toilet facilities for persons with disabilities (SANS 10400F )

  • Are lockers made available for staff (Facilities Regulations 3)

  • Dining rooms: Employees that are exposed to hazardous chemicals, or filth or soot, must have facilities provided to be able to eat their food (Facilities regulations 5)

  • Parking bay for Persons with disabilities (3.5 m and sign displayed)

  • Access for persons with disabilities

HAZARDS

  • HVAC system does it have fire dampers and is it linked with fire panel? (SANS10400; SANS 1238:2005; SANS 193)

  • Flammable liquids dedicated storage area (General Health and Safety Regulations, 2005 8. Use and storage of flammable liquids)

  • Hazardous Chemical Substances MSDS's (OHS Act Hazardous Chemical Substances Regulations, 1995)

  • In case of hazardous vapours, does every room, cabinet or enclosure to be fitted with an efficient intake and exhaust ventilation system? (OHS Act Hazardous Chemical Substances Regulations, 1996)

  • Are flammable stores separated, bunded and with certified electrical equipment

  • Fire chief permission certificate in file

  • No HOT work to be conducted in the area without the issuing of a HOT WORK PERMIT(Drilling, welding, grinding & flame cutting)

  • The edge of any balcony, bridge, flat roof or similar place more than 1 m above the adjacent ground or floor level shall be provided with a balustrade or parapet wall not less than 1 m in height, unless unauthorized access of persons thereto has been excluded by a physical barrier properly erected and maintained

  • Any balustrade or wall provided to protect a change in level shall comply with the requirements of SANS 10400B

  • Plain Glass doors marked with decals (SANS 10400B)

  • Push/pull signs required where doors do not open in direction of movement (outwards) (SANS 10400B)

  • Pillars in walkways have decals/pictures/notices attached (SANS 10400B)

  • Nonslip strips and proper handrails on tiled stairs (Environmental Regulations 6)

  • Head injuries/low areas mind your head signage displayed (OHS Act Section 8)

ELECTRICAL

  • COC Annexure A, accompanied by a test report, inspection and maintenance records to be kept on file and available at all times to an Inspector or an approved inspection authority (Electrical Installation Regulations 7 & 9, 2009)

  • COC issued by a competent electrician registered with the Department of Labour (Electrical Installation Regulations 7 & 9, 2009)

  • Electrical installation To be tested and inspected by a competent person on at least a 2 yearly basis – Master Electrician COC (Electrical Installation Regulations 7 & 9, 2009)

  • Infrared thermometry hotspots in electrical system (every 2-3 years)

  • Transformer annually service and maintain to include oil/gas analysis (Electrical Installation Regulations, 2009)

  • Generators Load tested on a monthly basis (Electrical Installation Regulations, 2009)

  • Generators Monthly load test (run for 30 minutes) (Electrical Installation Regulations, 2009)

  • Generators more than 20liters diesel to be stored in flammable liquids store (Electrical Installation Regulations, 2009)

  • Electrical plant rooms no storage (Electrical Machinery Regulations (EMR) 5)

  • Electrical plant rooms protection fire extinguisher/sprinkler system (EMR 5 & SANS 1186)

  • Electrical plant rooms notices at entrance. Inside and outside, general warning of electrical shock hazard labels/stickers on the panels (EMR 5 & SANS 1186)

  • Electrical plant rooms signage to indicate: This unit starts automatically Warning of hazard – moving machinery Wearing of loose clothing, ties, jewellery and unconfined hair prohibited Schedule D Colour Coding Chart Warning of slippery walking surfaces

  • Updated legend cards displayed to indicate circuit breakers on panels (EMR 5 & SANS 1186)

  • Power surge protection (EMR 5 & SANS 1186)

  • Electrical warning signage on all DB’s and electrical control panels (SANS 11861)

  • Ensure DB are kept locked at all times to prevent unauthorised access; however an access control system to be put in place in case of emergency (Electrical Machinery Regulations)

  • Panel cover secured to prevent access to live electrical wires (Electrical Machinery Regulations)

  • No HOT work to be conducted in the area without the issuing of a HOT WORK PERMIT(Drilling, welding, grinding & flame cutting)

  • Electrical cables/plugs properly insulated (Electrical Machinery Regulations 10)

  • Monthly Portable Electrical Tools Inspection (Electrical Machinery Regulations 10)

  • Appointed Competent Portable Electrical Tools Inspector (Electrical Machinery Regulations)

  • Portable Electrical Tools in good condition (Electrical Machinery Regulations)

SECURITY

  • Alarm SAIDSA approved/back up battery system/linked to armed response

  • CCTV monitoring data back up/monitored by security

  • Security guard (armed/armed response/panic button)

  • Electrical fencing compliance certificate (installers) (SANS 10222)

  • Keys management? Locked in a safe and control register?

  • Cash locked in a safe and handling procedures?

  • Access controlled

STACKING AND STORAGE

  • Stacking and Storage in a safe manner/stable/level (Construction Regulations 28)

  • Walkways kept clear of storage material

  • Are shelves braced/secured

  • Appointed and Competent Stacking and Storage Supervisor

  • Fire hazards

  • Monthly Stacking and Storage Inspection

  • Flammable liquids dedicated storage area (General Health and Safety Regulations, 2005 8. Use and storage of flammable liquids)

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.