Title Page

  • Application No. & Property Address

  • Contact Person's Details

  • Description of Works

  • Date of inspection

  • Inspection Officer

  • Certifier Registration No. BDC -

  • Are adequate environmental and amenity site controls in place?

  • Has a HBFC Certificate or Owner Builder permit been provided?

  • Pre-development Site Inspection

  • undefined

  • Footing Inspection

  • Set out of the building consistent with the approved documents?

  • Excavation area is in accordance with the approved documents?

  • Slab levels and ground levels consistent with the approved plans?

  • Footing locations, size and depths as per approved design?

  • Stepped footing reinforcement goes from top of top steel to bottom of bottom steel?

  • Cover to reinforcement satisfactory and trenches clear of lose material?

  • Slab thickness and thickening beams as per approved design?

  • Size, location, laps and corner details of reinforcement as per approved design?

  • Penetrations (e.g. plumbing) allow the element to perform as designed?

  • Damp proof barrier (eg.membrane) installed?

  • Termite barrier installed to penetrations and perimeter or use of slab edge as barrier?

  • Works is generally in accordance with the approved design?

  • undefined

  • Slab Inspection

  • Set out of the building consistent with the approved documents?

  • Excavation area is in accordance with the approved documents?

  • Slab levels and ground levels consistent with the approved plans?

  • Footing locations, size and depths as per approved design?

  • Stepped footing reinforcement goes from top of top steel to bottom of bottom steel?

  • Cover to reinforcement satisfactory and trenches clear of lose material?

  • Slab thickness and thickening beams as per approved design?

  • Size, location, laps and corner details of reinforcement as per approved design?

  • Penetrations (e.g. plumbing) allow the element to perform as designed?

  • Damp proof barrier (eg.membrane) installed?

  • Works is generally in accordance with the approved design?

  • Termite barrier installed to penetrations and perimeter or use of slab edge as barrier?

  • undefined

  • Other In-situ Concrete Structure

  • undefined

  • Stormwater Inspection

  • Stormwater drainage connection(s) visible and able to be inspected?

  • Stormwater drainage connection(s) consistent with the approved design or satisfactory?

  • Type of pipes consistent with the approved design or satisfactory?

  • Pipe sizes consistent with the approved design or satisfactory?

  • Where stormwater management, or civil design, has been approved a works as executed drawing and/certification has been provided?

  • undefined

  • Frame Inspection

  • Layout and configuration is consistent with the approved documents?

  • Size and span of timbers, stress grades, durability, bushfire resistance satisfactory?

  • Point & concentrated loads supported?

  • Structural steel as per approved design?

  • Notching and penetrations of framing elements satisfactory?

  • Cavity width, cavity ties, flashings and dampproof courses satisfactory?

  • Articulation joints provided in brickwork?

  • Bracing location, type, nailing pattern and fixing to slab or floor frame satisfactory?

  • Tie-down location, type and fixing from roof frame to floor frame or slab satisfactory?

  • Wet area substrate is concrete, compressed FC or WR plywood?

  • If particleboard floor, discuss wet areas and possible use of FC tile underlay product.

  • Accessible sanitary compartments, doorways and circulation spaces to AS 1428?

  • undefined

  • Wet Area Inspection Inspection

  • Location & type of wet areas consistent with approved plans?

  • Waterproofing system consistent with approved documents/spec’s?

  • Membrane installed to the extent required?

  • Substrate material appropriate for its intended use?

  • Membrane appropriate for its intended use?

  • Membrane installed to manufacturers’ spec’s as far as can be ascertained?

  • Membrane installed without defects or damage (no holes/damage etc)?

  • Waterstops installed at doorways and other locations as required?

  • undefined

  • Fire Rated Construction / Penetrations Inspection

  • undefined

  • Swimming Pool Barrier Inspection

  • undefined

  • Final Inspection

  • OC Application been lodged on NSW Planning Portal?

  • A Construction Certificate or Complying Development Certificate been issued?

  • Council has the following documents that have been relied upon?<br>• Development Consent<br>• Construction Certificate or Complying Development Certificate<br>• Approved Plans and Specifications.<br>• BASIX certificate (if required)<br>• Critical stage inspection reports<br>• Relevant compliance certificates

  • The building is consistent with development consent?

  • The building is consistent with the BASIX Certificate?

  • All critical stage inspections been carried out?

  • Any Pre-Occupation Certificate conditions been satisfied?

  • All other conditions of consent been satisfactorily satisfied?

  • There are no outstanding compliance actions or orders and any complaints made by the public been resolved or addressed?

  • The building is suitable for occupation in accordance with its classification?

  • The building will not be a hazard to the health & safety of the occupants?

  • undefined

  • Other Building Inspection

  • undefined

  • Is this a re-inspection?

  • undefined

  • Have all necessary compliance certificates been provided? If "No", please provide those certificates as marked.

  • AHD Floor Level Certificate

  • AHD Fill Level Certificate

  • Termite Management Certificate

  • Set-out survey

  • Certificate for foundation material

  • Amended engineering details for variation of works

  • Certification of slip resistant stair finish to AS 4586

  • Waterproofing Certificate

  • Glazing of windows and doors

  • Glazed assemblies that are not in external walls

  • Glazing of balustrades and / or pool fencing

  • Smoke alarm installation certificate

  • Certification of penetrations to Fire Rated Elements

  • Certification of construction to sound transmission levels

  • Certification of all the installation of all BASIX commitments

  • Roof truss Certificate

  • Insulation Certificate

  • Pool water recirculation system to AS 1926.3

  • Final Fire Safety Certificate

  • undefined

  • General Notes

  • undefined

  • Inspection Result

  • Matters to be addressed

  • undefined

  • Is re-inspection required?

  • Matters to be addressed

  • undefined

  • Inspection Officer’s Signature:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.