Title Page
Bulk LP-Gas Storage Annual Inspection
-
Location Name:
-
Container(s) Physical Address:
-
Inspection Date:
-
Inspected by:
Storage Container(s) Information
-
LP-Gas Storage Facility Photo(s):
-
Add A Storage Container:
Storage Container
-
Capacity:
-
Serial Number:
-
National Board Number:
-
Manufacturer Name:
-
Year Built:
Vaporizer Information
-
Vaporizer Photo(s):
-
Add A Vaporizer:
Vaporizer
-
Manufacturer Name:
-
Model Number:
-
Serial Number:
-
Year Built:
-
Maximum Vaporizing Capacity - GPH:
-
Burner Input BTU per Hour:
Bulk Storage Containers
-
Is the manufacturer's data plate secured and legible?
-
Is the data plate free of corrosion?
-
Is the pressure rating proper for the product?
-
Are above ground tanks properly painted?
-
Are containers free of excess corrosion, damage, dents, gouges, or other damage?
-
Are all container markings and decals in accordance with NFPA 58?
-
Are foundations in good condition?
-
Are containers/saddles free of corrosion at masonry contact areas?
-
Are saddle pads in good condition?
-
Are connections on containers greater than 2,000 gallon water capacity marked "vapor" or "liquid"?
-
Are all unused openings plugged or capped?
-
Are all container fittings leak-free?
-
Are pressure gauges in good condition and suitable for 250 psig service (such as 0 - 400 psig)?
-
Are thermometers in good condition?
-
Are liquid level gauges arranged and installed so that the liquid level can be accurately determined?
-
Is relief valve data legible?
-
Are the relief valves marked for use with LP-Gas and labeled by an independent testing agency?
-
Do relief valves communicate with the container vapor space and discharge upward, unobstructed to the open air?
-
Are relief valves equipped with vent stacks of proper diameter and length?
-
Are relief valve vent stacks equipped with breakaway couplings?
-
Do relief valve vent stacks have loose fitting protective caps or closures to prevent entry of foreign matter?
-
Are weep holes for moisture drainage open?
-
Are the valve body seams leak free?
-
Are ESV's in good working condition and leak free?
-
Is the pneumatic control system in good working condition?
-
Are remote emergency shutoff devices between 25 and 100 feet from the ESV and within the path of egress?
-
Is the thermal link intact and free of paint?
-
Are manual shut-off valves located so that they can be easily reached during normal operations and in an emergency?
-
Are valves in good condition and leak free?
-
Do valves have the proper service pressure rating, equal to or greater than the maximum allowable working pressure of the container?
-
Are catwalk railings provided and in good condition?
-
Are stairways well anchored and supported?
-
Does decking design offer drainage and prevent accumulation?
-
Is the area within 10 feet of the containers free of weeds, long grass, rags, paper, wood or other loose or piled combustible materials?
-
LP-Gas storage tank is underground.
-
Is protection against vehicular damage provided for the fitting housing, housing cover, tank connections and piping?
-
Is the container protected against corrosion by at least one of the following means:
-
Cathodic protection?
-
An external coating on the tank?
Piping
-
Are aboveground pipes properly painted?
-
Are pipes free of corrosion damage, dents, gouges or other damage?
-
Are pipes adequately supported?
-
Are pipes adequately protected against damage by vehicles?
-
Are pipes properly marked "vapor" or "liquid" or color coded accordingly?
-
Are all flanges and fittings properly sized for the pressure rating, equal to or greater than the maximum allowable working pressure of the system?
-
Are all stainless steel flex connectors in good working condition?
-
Are all flow indicators and sight checks in proper working condition and leak free?
-
Are all fittings and pipes leak free?
-
Are hydrostatic relief valves installed in each section of piping in which liquid can be isolated between shut-off valves?
-
Are hydrostatic relief valves approved for use with LP-Gas?
-
Do the hydrostatic relief valves have pressure settings between 400 - 500 psig?
-
Are valves located so that they can be easily reached during normal operations and in an emergency?
-
Are valves in good condition and leak free?
-
Do valves have the proper pressure rating, equal to or greater than the maximum allowable working pressure of the system?
-
Underground piping is present.
-
Is metallic underground piping protected against corrosion by at least one of the following means:
-
An external coating on piping?
-
Cathodic protection?
Pumps / Compressors
-
Liquid Pump (check if system has a liquid pump)
-
Are pump pads and/or foundations in good condition and properly supporting the pumps?
-
Are base plate bolts in place and properly securing the pump to the foundation?
-
Are pumps free of corrosion or other damage?
-
Are the pumps properly lubricated?
-
Are hydrostatic relieve valves installed in the appropriate location(s) and in good working condition?
-
Are fittings and piping associated with the pump leak free?
-
Are bypasses in good working condition and leak free?
-
Are drive belts properly aligned and in good working condition?
-
Shaft Coupling-Driven Pumps:
-
Are shaft couplings properly aligned?
-
Are spacing bushings in good working condition?
-
Gear Reduction-Driven Pumps:
-
Are universal joints and couplings properly aligned and in good working condition?
-
Vapor Compressor (check if system has a vapor compressor)
-
Are compressors free of corrosion or other damage?
-
Are compressor pads and/or foundations in good condition and properly supporting the compressors?
-
Are base plate bolts in place and securing the compressor to the foundation?
-
Are the compressors properly lubricated?
-
Is the crankcase oil properly filled?
-
Is the crankcase oil pressure properly set?
-
Has the oil filter been changed at the manufacturer's recommended interval?
-
Are strainers in good working condition and leak free?
-
Are pressure relief valves installed in the appropriate location and in good working condition?
-
Are all back check valves in proper working condition and leak free?
-
Are fittings and piping associated with the compressor leak free?
-
Are drive belts properly aligned, tension properly set, and in good working condition?
-
For direct drive compressors, are shaft couplings properly aligned and in good working condition?
-
Are drive belt / shaft coupling guards in place and secure?
-
Are strainers in good working condition and leak free?
-
Are all stainless steel flex connectors in good working condition?
-
Are pressure gauges in good condition?
-
Are valves located so that they can be easily reached during normal operations and in an emergency?
-
Are valves in good condition and leak free?
-
Do valves have the proper pressure rating, equal to or greater than the maximum allowable working pressure of the system?
Bulkheads
-
Are bulkheads properly protected against vehicular damage?
-
Are bulkheads in good condition and properly supporting the bulkhead, especially in the event of a pull-away?
-
Are pipe nipples and couplings that are attached to the bulkhead in good working condition and free of excessive wear?
-
Are all flanges and fittings properly sized for the pressure rating, equal to or greater than the maximum allowable working pressure of the system?
-
Are all stainless steel flex connectors in good working condition?
-
Are all flow indicators and sight checks in proper working condition and leak free?
-
Are hydrostatic relief valves installed in the appropriate location and in good working condition?
-
Are all fittings and pipes leak free?
-
Are ESV's in good working condition and leak free?
-
Is the pneumatic control system in good working condition?
-
Are remote emergency shutoff devices between 25 and 100 feet from the point of transfer and within the path of egress?
-
Are the hose covers free of exposed reinforcement?
-
Are hoses free of kinks and not flattened?
-
Are hoses free of soft spots when not under pressure, show no bulging under pressure, and have no loose outer coverings?
-
Are hose coupling assemblies secure and in good working condition?
-
Are the ACME threads and O-rings / gaskets in good working condition?
-
Are valves located so that they may be easily reached during normal operations and in an emergency?
-
Are valves in good condition and leak free?
-
Do the valves have the proper pressure rating, equal to or greater than the maximum allowable working pressure of the system?
Scales
-
Has the scale(s) been checked periodically using a certified / standard dead weight?
-
Has the scale(s) been certified by the appropriate authority having jurisdiction?
-
Have all loops, pivots, and bearings been periodically lubricated?
-
Are the scale pit(s) and/or platform(s) free of debris?
-
Are all actuators and control valves leak free and in good working condition?
-
Are all sensing lines leak free and in good working condition?
-
Are the hose covers free of exposed reinforcement?
-
Are hoses free of kinks and not flattened?
-
Are hoses free of soft spots when not under pressure, show no bulging under pressure, and have no loose outer coverings?
-
Are hose coupling assemblies secure and in good working condition?
-
Are the ACME threads and O-rings / gaskets in good working condition?
Meters (For Retail Sales Only)
-
Is the meter(s) properly calibrated or "proved" at the appropriate time intervals?
-
Is the seal(s) in place by the appropriate authority having jurisdiction?
-
Is the meter in good working condition and free of leaks?
-
Is the strainer in good working condition and leak free?
-
Are the hose covers free of exposed reinforcement?
-
Are hoses free of kinks and not flattened?
-
Are hoses free of soft spots when not under pressure, show no bulging under pressure, and have no loose outer coverings?
-
Are hose coupling assemblies secure and in good working condition?
-
Are the ACME threads and O-rings / gaskets in good working condition?
-
Are pull-away couplings in place and in good working condition?
Vaporizers
-
Is the vaporizer(s) leak free and in good working condition?
-
Have pilot lights been cleaned on a regular basis?
-
On a periodic basis, have all strainers been cleaned at the inlet side of the vaporizer(s)?
-
Have heavy ends been cleaned from the vaporizer(s) and/or separator tank?
-
Have the burner openings, thermostat, and flue been cleaned?
-
Is the vaporizer(s) located in accordance with NFPA 58?
Regulators
-
Is the first-stage or high-pressure regulator directly attached by flexible connectors to the vaporizer outlet or to the interconnected piping of manifolded vaporizers?
-
Are all first-stage and high-pressure regulators installed outside of buildings?
-
Are all regulators that are outside of buildings installed and protected so that their operation will not be affected by environmental elements or insects?
-
Is the point of discharge on the regulator's relief device at least 3 feet horizontally away from any building opening that is below the level of the discharge?
-
Is the point of discharge on the regulator's relief device located at least 5 feet in any direction from any source of ignition or mechanical ventilation air intakes?
Electrical Systems
-
Are electrical components and wiring contained in explosion-proof housings and conduit and in goofing working condition?
-
Are all seal-off fixtures filled with suitable putty and installed in the appropriate locations?
-
Are pump and/or compressor switches readily accessible to the operator?
-
Are electrical controls for equipment clearly marked or color-coded to indicate the on and off (stop) positions?
-
Is the electrical emergency shutdown located more than 20 feet (but less than 100 feet) from dispensing devices and prominently labeled?
Fire Extinguishers
-
Add A Fire Extinguisher:
Fire Extinguisher
-
Extinguisher number or location:
-
Size and rating:
-
Date of last annual inspection:
Sign Off:
-
All items, applicable to the LP-Gas storage installation, have been inspected according to the standards set forth in the Operation and Maintenance Handbook.
-
Signature:
-
Comments:
Follow-up:
-
All unsatisfactory items contained in this inspection have been corrected.
-
Signature & Date: