Swimming Pool/Spa Report Number
-
Location
-
Swimming Pool/Spa construction date
-
Inspection date
-
Contact person's name & company name (if applicable)
-
Contact phone number(s)
-
Contact email address
-
Prepared by (inspector's name)
AS 1926 - 1993 This swimming pool/spa barrier safety audit applies to swimming pools and spas constructed, or which building approval (building permit) was granted between 8 April 1991 and 30 April 2010. Please confirm approval date on the building permit document prior to proceeding with this audit.
-
IS THE BUILDING PERMIT APPROVAL DATE PRIOR BETWEEN 8 APRIL 1991 AND 30 APRIL 2010?<br><br>If no, specify building permit approval date and take photo of building permit and/or Pathway building permit record specifying approval date. Switch to appropriate audit version to suit swimming pool/spa construction/approval date (see notes below).<br><br>Notes:<br><br>Building Regulations PART 7 - Pools/spas constructed or for which approval was granted prior to 8 April 1991.<br><br>AS 1926 - 1993 - Pools/spas constructed or for which building approval was granted between 8 April 1991 and 30 April 2010.<br><br>AS 1926 - 2007 - Pools/spas constructed or for which building approval was granted between 1 May 2010 and 30 April 2013.<br><br>AS 1926 - 2012 - Pools/spas constructed or for which building approval was granted between 1 May 2013 and present day.
-
IS THERE A SWIMMING POOL/SPA SAFETY BARRIER INSTALLED? <br><br>If yes, take overview photo(s) of barrier.<br><br>If no, take overview photo(s) of barrier; and <br><br>Issue an Emergency Order (s.102) to provide a compliant temporary barrier within 7 days; and<br><br>Issue a Building Order for Minor Work (s.113) to construct a permanent swimming pool/spa safety barrier after first obtaining a building permit. Building Order for Minor Work to remain in force until such a time that a Certificate of Final Inspection is issued for the permanent barrier. <br><br>Compliant temporary barrier is to remain in place until such a time that a Certificate of Final Inspection is issued for a permanent pool/spa safety barrier constructed under a valid building permit.<br><br><br><br>
WINDOW COMPLIANCE
-
DO BUILDING(S) WITH WINDOW OPENING(S) FACING INTO THE SWIMMING POOL/SPA ENCLOSURE AREA FORM PART OF THE SWIMMING POOL/SPA SAFETY BARRIER?<br><br>If yes, specify number of window(s), note location(s) and take photo(s).
-
IS THE OPENABLE PART OF THE WINDOW NOT LESS THAN 2.4m ABOVE THE GROUND OR PAVING LEVEL IMMEDIATELY EXTERNAL TO THE WINDOW?
-
IS THE OPENABLE PART OF THE WINDOW NOT LESS THAN 1.2 ABOVE THE FLOOR OF THE ROOM CONTAINING THE WINDOW?<br><br><br>If yes, take photo(s) and note location(s).
-
ARE WINDOW(S) RESTRICTED TO OPEN A MAXIMUM OF 100mm BY A CATCH, BOLT, LOCK OR OTHER STOP LOCATED NOT LESS THAN 1.5m ABOVE THE FLOOR OF THE ROOM CONTAINING THE WINDOW?<br><br>If yes, take photo(s) and note location(s)<br><br><br>
-
IS A SECURELY FITTED FLY SCREEN INSTALLED?<br><br>If yes, take photo(s) and note location(s).
-
ARE WINDOW(S) OPENING INTO SWIMMING POOL ENCLOSURE DEEMED COMPLIANT?<br><br>If no, specify location(s) and take photo(s).
CHILD-RESISTANT DOORSET COMPLIANCE
-
DO BUILDING(S) CONTAINING CHILD-RESISTANT DOORSET(S) THAT OPEN DIRECTLY INTO THE SWIMMING POOL/SPA ENCLOSURE AREA FORM PART OF THE SWIMMING POOL/SPA SAFETY BARRIER?<br><br>If yes, specify number of child-resistant doorset(s), note location(s) and take photo(s).
-
IS THE CHILD-RESISTANT DOORSET(S) FITTED WITH A DEVICE THAT RETURNS THE DOOR TO ITS CLOSED AND LATCHED POSITION FROM FULLY OPEN TO RESTING ON THE LATCH WITHOUT THE APPLICATION OF MANUAL FORCE?<br><br>If no, specify location(s) and take photo(s).
-
DO CHILD-RESISTANT DOORSET(S) HAVE A SELF-LATCHING OR SELF-LOCKING MECHANISM?
-
ARE CHILD-RESISTANT DOORSET(S) OPENING MECHANISM(S) LOCATED 1.5m MINIMUM ABOVE THE GROUND LEVEL OR INTERNAL FLOOR LEVEL (as the case may be) MEASURED FROM THE APPROACH SIDE?
-
ARE CHILD-RESISTANT DOORSET(S) DEEMED COMPLIANT?
FENCING (including boundary fencing)
-
DO SECTION(S) OF BOUNDARY FENCING FORM PART OF THE SWIMMING POOL/SPA SAFETY BARRIER?<br><br>If yes, take photo(s).
-
IS FENCING 1.2m MINIMUM IN HEIGHT MEASURED FROM THE APPROACH SIDE?<br><br>If no, specify height(s), take photo(s) and nominate location(s) of non-compliance.
-
DOES FENCING (including boundary fencing) CONTAIN HORIZONTAL MEMBERS ON THE APPROACH SIDE?<br><br>If yes, take photo(s) and confirm measurements.<br><br>
-
ARE HORIZONTAL MEMBER(S) 900mm MINIMUM APART? (measured from top surface of lowest upper member to top of highest member)<br><br>If no, take measurement(s), note location(s) and take photo(s).<br><br>Note : On sloping sites measurements taken perpendicular to finished ground level.
-
IS THERE A MINIMUM DISTANCE OF 1100mm FROM THE LOWEST HORIZONTAL MEMBER TO THE TOP OF THE BARRIER? (measured from top surface of lowest horizontal member to top of fence)<br><br>If no, take measurement(s), note location(s) and take photo(s).<br><br>Note : On sloping sites measurements taken perpendicular to finished ground level.
-
HAVE HORIZONTAL MEMBERS BEEN TREATED APPROPRIATELY AS TO NOT ACT AS A FOOTHOLD?<br><br>If yes, select type of treatment, take photo(s) and note location(s).
-
DOES PERFORATED MATERIAL OR MESH FENCING HAVE APERTURES NOT GREATER THAN 13mm?<br><br>If no, specify location(s) of non-compliance(s) and take photo(s).
-
DOES PERFORATED MATERIAL OR MESH FENCING HAVE APPERTURES BETWEEN 13mm AND 100mm?<br><br>If yes, specify location(s) and take photo(s).
-
IS PERFORATED MATERIAL OR MESH FENCING (apertures 13mm to 100mm) A MINIMUM OF 2.4m IN HEIGHT? (Measured from the approach side of the barrier) <br><br>If no, specify location(s) of non-compliance(s) and take photo(s).
-
IS PERFORATED MATERIAL OR MESH FENCING (apertures 13mm - 100mm) 1800mm MINIMUM IN HEIGHT (measured from approach side of barrier) WITH A CRANKED TOP (90-135 deg) 450mm MINIMUM LONG?<br><br>If no, specify location(s) of non-compliance(s) and take photo(s).
-
IS SWIMMING POOL/SPA SAFETY BARRIER FENCING COMPLIANT?
RETAINING WALLS OR OTHER SUCH BARRIERS
-
DO RETAINING WALL(S) OR OTHER SUCH BARRIER(S) FORM PART OF THE SWIMMING POOL/SPA SAFETY BARRIER?<br><br>If yes, specify location(s) and take photo(s).
-
DOES THE RETAING WALL OR OTHER SUCH BARRIER HAVE AN EFFECTIVE MINIMUM HEIGHT OF 2.4m?<br><br>If no, specify height(s), location(s) and take photo(s).
-
DOES THE RETAINING WALL OR OTHER SUCH BARRIER SLOPE AWAY FROM THE POOL/SPA BY MORE THAN 15 DEGREES TO THE VERTICAL?<br><br>If yes, specify angle(s), note location(s) and take photo(s).
-
DOES THE RETAINING WALL OR OTHER SUCH BARRIER CONTAIN PROJECTIONS OR INDENTATIONS GREATER THAN 10mm IN WIDTH?<br><br>If yes, specify location(s), note width(s) and take photo(s).
-
ARE PROJECTION(S) / INDENTATION(S) EXCEEDING 10mm IN WIDTH GREATER THAN 900mm APART?<br><br>If no, specify location(s), note distance(s) and take photo(s).
-
ARE PROJECTION(S) / INDENTATION(S) EXCEEDING 10mm A MINIMUM OF 1100mm FROM THE TOP OF THE RETAINING WALL OR OTHER SUCH BARRIER?<br><br>If no, specify location(s), note distance(s) and take photo(s).
-
DO RETAINING WALLS OR OTHER SUCH BARRIERS FORMING PART OF THE SWIMMING POOL SAFETY BARRIER COMPLY?
GATES AND FITTINGS
-
ARE GATE(S) 1.2m MINIMUM IN HEIGHT MEASURED FROM THE APPROACH SIDE?<br><br>If no, specify locations(s) and take photo(s).
-
DO SWIMMING POOL SAFETY BARRIER GATE(S) OPEN OUTWARD (away from the pool enclosure area)?<br><br>If no, specify locations(s) and take photo(s).
-
ARE GATE(S) FITTED WITH A DEVICE THAT RETURNS THE GATE TO ITS CLOSED AND LATCHED POSITION FROM FULLY OPEN TO RESTING ON THE LATCH WITHOUT THE USE OF MANUAL FORCE?<br><br>If no, specify locations(s) and take photo(s).
-
DO GATE(S) HAVE A SELF-LATCHING OR SELF-LOCKING MECHANISM?
-
ARE GATE OPENING MECHANISM(S) LOCATED 1.5m MINIMUM ABOVE THE GROUND/PAVED LEVEL MEASURED FROM THE APPROACH SIDE?<br><br>If no, specify locations(s) and take photo(s).
-
WHERE NOT LOCATED AT 1500mm IN HEIGHT, ARE GATE OPENING MECHANISM(S) LOCATED 150mm MINIMUM FROM THE TOP OF THE INSIDE OF THE GATE? <br><br>Note:<br><br>- Solid surface gate with any openings not exceeding 10mm within 450mm of opening mechanism.<br>- 1200mm minimum gate height measured from approach side.<br>-
-
WHERE NOT LOCATED AT 1500mm IN HEIGHT, ARE GATE OPENING MECHANISM(S) SHIELDED WITH AN EFFECTIVE RADIUS OF 450mm?<br><br>If no, specify location(s) and take photo(s).
-
WHERE GATE OPENING MECHANISM(S) ARE SHIELDED, ARE GAPS WITHIN 450mm OF THE OPENING MECHANISM NO GREATER THAN 10mm?<br><br>If no, specify location(s) and take photo(s).
-
WHERE A HAND-HOLE HAS BEEN PROVIDED, IS THE OPENING 1.2m MINIMUM FROM GROUND/PAVED LEVEL MEASURED FROM THE APPROACH SIDE?<br><br>If no, note location(s) and take photo(s).
-
WHERE A HAND-HOLE HAS BEEN PROVIDED, IS THE OPENING 1.1m MINIMUM FROM THE HIGHEST LOWER HORIZONTAL MEMBER?<br><br>If no, note location(s) and take photo(s).
-
WHERE A HAND-HOLE HAS BEEN PROVIDED, IS THE BOTTOM OF THE HAND-HOLE OPENING 150mm MINIMUM FROM THE OPENING MECHANISM?<br><br>If no, note location(s) and take photo(s).
-
WHERE A HAND-HOLE HAS BEEN PROVIDED, IS SHIELDING 150mm MINIMUM ABOVE OPENING MECHANISM?<br><br>If no, note location(s) and take photo(s).
-
DO SWIMMING POOL/SPA SAFETY BARRIER GATE(S) AND FITTINGS COMPLY?
BALCONIES
-
DO ANY BALCONIES PROTRUDE INTO THE SWIMMING POOL/SPA ENCLOSURE AREA?
-
IS ACCESS TO THE BALCONY RESTRICTED WITH A COMPLIANT SWIMMING POOL/SAFETY BARRIER?
-
IS THE BALCONY FLOOR LEVEL LESS THAN 2400mm TO THE POOL/SPA SURROUND?<br><br>If yes, specify height and take photo(s).
-
IS THE BALCONY BALUSTRADE REQUIRED TO BE COMPLIANT WITH THE REQUIREMENTS OF A SWIMMING POOL SAFETY BARRIER?<br><br>
-
IS THE BALCONY BALUSTRADE COMPLIANT WITH THE REQUIREMENTS OF A SWIMMING POOL SAFETY BARRIER?<br><br>If no, specify non-compliance(s), note location(s) and take photo(s).
-
-