Title Page
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
-
Operative being assessed
Action on site
-
Uses the Voltstick prior to undertaking any work on any exposed metalwork to ensure it is safe to <br>continue and repeats when necessary
-
Carries out checks to establish the number of customers being supplied and isolates ECV prior to <br>disconnection
-
Removes wrapping from the service pipe at two places where cuts will be made, approximately 300mm <br>apart and cleans pipe
-
Fits a temporary continuity bond (TCB) across section to be removed ensuring that the pipe where the <br>TCB is to be clamped is clean and wired brushed to a bright finish to ensure a good electrical contact
-
Question - What action needs to take place if the Voltstick glowed or sparking occurred when fitting or removing the TCB?
-
Answer - Cease work and advise team manager
-
Wraps the pipe with a suitable denso tape/ mastic bandage prior to cutting
-
Dons breathing apparatus complete with associated PPE
-
Cuts through the denso tape/mastic bandage and pipe using a hacksaw and seals the cut with the <br>mastic as the cutting proceeds to minimise release of gas. Ensures that the cut piece (approx. 300mm) <br>can be easily removed<br>
-
Removes the cut section and fits caps to both ends, removes bend and plugs hole with the minimum <br>delay to reduce loss of gas
-
Question - What action should be taken to the plug to avoid a build-up of static charge and the possibility of a <br>spark?<br>
-
Answer - The plug should be earthed by resting the plug on the main about 350mm from the hole and slid along the
surface of the pipe to the hole -
Tests the plug with SGN approved leak detection fluid
-
Removes continuity bond once the atmosphere is gas free
-
Disconnects / removes the existing standpipe, where possible and seals the standpipe entry
-
Question - What action should be taken if it is not possible to remove the standpipe?
-
Answer - The standpipe should be left in-situ and capped off and labelled with (SGNB608) to indicate service
disconnected -
Seals any abandoned service pipe ends in the ground using suitable caps
-
Checks properties to confirm that only the properties to be cut-off have been isolated
Sign off
-
Name of assessor
-
Pass or refer for additional training