  • DN-10 - Dead service insertion

  • o = Observed K = Knowledge S = Simulated

  • Actions on site

  • Carries out a visual inspection of the existing steel service to check for severe corrosion

  • Confirms excavations have been made at the connection point of the main or a minimum distance of 2m from the building line for insertion into the building using a compression fitting

  • Confirms the service has been decommissioned and the service purged to 0% GIA using a purge hose

  • Removes the ECV and checks for any elbows or partial blockages of the existing service pipe by inserting a flexible rod down the standpipe

  • Measures the length of the existing service and calculates the properties gas load requirements

  • Calculates the diameter of the replacement service and confirms that the diameter of the existing service is suitable for dead insertion in order to determine the maximum pressure drop allowable for the complete length of the service pipe

  • Ensures the existing service pipe has no debris or restriction inside thus preventing insertion

  • Question - What can be done to clear any debris or restrictions inside the existing service pipe?

  • Answer: Remove any restriction (bends etc.) and/or clear the pipe by using a wire brush or by introducing air from inside to the outside

  • Plugs the leading end of the PE using a bullet type nose cone to assist insertion and preventing debris from entering the pipe

  • Checks an effective form of communication is established before undertaking starting the insertion process

  • Inserts the pipe using a pipe pushing machine or by hand, takes care when pushing through bends to ensure that the PE pipe does not kink or become trapped

  • Ensures that at least 1 metre of PE pipe is visible beyond the standpipe and carries out a visual inspection for damage

  • Question - At what percentage of scoring of the wall thickness must the PE not be used?

  • Answer - Greater than 10%

  • Cuts back sufficient pipe and fits service head adaptor in accordance with manufacturer’s instructions

  • Ensures that there is an IECV or insulation joint fitted to the service head adaptor, if required

  • Connects the PE service pipe to the main or live inserted PE pipe within the garden

  • Carries out a pressure test in accordance with current SGN procedures

  • Commissions / purges the services in accordance with current SGN procedures and tests all untested <br>joints using approved leak detection fluid

  • Seals the end of the old service using an approved method and fills the annulus with correct quantities <br>of approved annular sealant in accordance with the manufacturer’s instructions

  • Fits any electrical insulation onto the steel pipe as per current SGN procedures

  • Completes service information label and attaches it to the ECV

Sign off

  • Name of assessor

  • Pass or refer for additional training

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.