Title Page

  • Conducted on

  • Prepared by

  • Site Address
  • Tesseract Site Code:

Scope of Work

  • Scope of Work

    Please follow the below scope of works for various installations, dependant on what is presented on site;

    Dedicated Circuits - disconnected at the distribution board(s), cabling removed where possible to first detector. Where cabling cannot be removed, feed at first detector terminated in blocks and placed in Chocbox

    If the smoke detectors were:

    Wired from the local lighting circuit - safely isolating the circuit at fitting before removing the cabling to the smoke detector points. Remove detectors and bases. Where cabling cannot be removed, terminate in blocks and place in Chocbox

    The above would support a Satisfactory report rating as per NICEIC

Condition of Site

  • Condition of system on arrival

  • Is Fire Detection on independent circuit?

  • Has circuit been removed from consumer board?

  • Please ensure feed is removed from board and terminated at first fitting in termination blocks and connection box

  • Detectors are being fed from local circuit? (eg lighting?

  • Remove feed cable from light fitting and terminate in blocks / chocbox

Additional information

  • Additional Information

  • Additional Photographs (if needed)

  • Site left in safe condition

  • Is revisit required?

  • Provide details

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.