Title Page
-
Conducted on
-
Prepared by
-
Location
-
Tesseract Site Code:
Scope of Work
-
Scope of Work
Please follow the below scope of works for various installations, dependant on what is presented on site;
Dedicated Circuits - disconnected at the distribution board(s), cabling removed where possible to first detector. Where cabling cannot be removed, feed at first detector terminated in blocks and placed in Chocbox
If the smoke detectors were:
Wired from the local lighting circuit - safely isolating the circuit at fitting before removing the cabling to the smoke detector points. Remove detectors and bases. Where cabling cannot be removed, terminate in blocks and place in Chocbox
The above would support a Satisfactory report rating as per NICEIC
Condition of Site
-
Condition of system on arrival
-
Please provide detail
-
Has cabling been correctly terminated as per scope?
-
Please provide detail
-
Is Fire Detection on independent circuit?
-
Has circuit been removed from consumer board?
-
Photo of feed removed from board
-
Has feed to first device been placed in termination blocks and isolation box?
-
Photo of first feed in termination blocks / isolation box
-
Please ensure feed is removed from board and terminated at first fitting in termination blocks and connection box
-
Photo of completed work
-
Please ensure feed is removed from board and terminated at first fitting in termination blocks and connection box
-
Photo of feed removed from board
-
Photo of first feed in termination blocks
-
Photo of first feed in connection box
-
Detectors are being fed from local circuit? (eg lighting?
-
Remove feed cable from light fitting and terminate in blocks / chocbox
-
Photos before / as found
-
Photos of remedial work complete
Photographs
-
Where detectors are fed from local lighting circuits please record locations (eg. Ground floor, first floor) with before and after photos to demonstrate site left in safe condition
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
-
Additional detector?
-
Location
-
Before / As found
-
After / As Left
Additional information
-
Additional Information
-
Additional Photographs (if needed)
-
Site left in safe condition
-
Is revisit required?
-
Provide details