Lease Entrance

  • Company

  • Proper signage and sign in sheet at entrance to pad. Ref. API RP 67 2.4.2, API RP 54 5.1-5.4' I.S., API RP 49, RP54 8.41d, 1910.145(c)(2)(I)

  • No smoking

  • Proper PPE

  • Radioactive source

  • Notify company man upon arrival

  • H2S signage

  • Medical services, driving directions, first aid kit posted. Ref. 1910.151(b), RP54 4.1-4.3

  • Additional Comments

Frac Tanks

  • Company

  • Quick connect pipe from fresh water source free of leaks or damage. Ref. CHK BMP

  • Water manifold to tanks free of leaks, all valves to operate present , and in containment if re-use water is used. Ref. CHK BMP, I.S.

  • All lines from manifold into tank secured to tank. Ref. CHK BMP

  • Tanks set level. Ref. CHK BMP

  • Stairs, handrails, and walkways pinned, connected and not damaged, with no open holes. Ref. RP54 9.3.8, 1910.24(h)

  • Frac company has sewage to go from frac tanks to F.D. Coupling. Ref. CHK BMP

  • Frac tanks grounded. Ref. RP2003 4.5.2

  • Valves double blocked when not in use. Ref. CHK BMP

  • Additional Comments

Hydration Unit

  • Company

  • Suction hoses from frac tank to hydration unit free from abrasions, cuts, and gouges. Hose rated to 100psi. With factory ends. Ref. RP54 16.1.7/OEM

  • Hydration unit in containment. Ref. CHK BMP

  • Containment free of holes and sides are up

  • Hydration unit grounded

  • Stairs and walkways free of clutter and undamaged. Hand rails up and pinned. Ref. RP54 9.3.8, 1910.24(h)

  • SDS of all chemicals on site. Ref. 1910.1200

  • Chemicals are properly labeled. Ref. 1910.1200

  • All personnel wearing proper PPE per SDS. Ref. 1910.1200, CHK Policy, 1910.132

  • F.E.'s charged, inspected and ready for service. Ref. RP 54 20.3.4, 1910.252(a)(2)(ii)

  • Hydration unit free of leaks. Ref. BMP

  • Hoses from hydration to blender free from abrasions, gouges, and cuts. Hose rated to 100 psi with factory ends. Whip checks installed properly. RP54 16.1.7/ OEM

  • Additional Comments

Blender

  • Company

  • Blender in containment. Ref. CHK BMP

  • Containment free of holes and sides are up.

  • Hydraulic hoses in vicinity of turbo sheathed. Ref. RP54 16.1.7

  • Blender free of leaks. Ref. BMP

  • Radiation source (densitometer) labeled, closed, and locked. Ref. 1910.1096(j)

  • All personnel wearing proper PPE per SDS. Ref. 1910.1200/ CHK Policy

  • Valves double blocked when not in use on suction and discharge side. Ref. CHK BMP

  • Hoses on discharge side of blender to missile free from abrasions, gouges, and cuts. Hose rated to 250 psi with factory ends. Whip checks installed properly. Ref. RP54 16.1.7, RP54 9.13.3

  • F.E.'s charged, inspected and ready for service. Ref. 1910.252(a)(2)(ii)

  • Stairs and walkway free of clutter and undamaged. Hand rails are up and pinned. Ref. RP54 9.3.8, 1910.24(h)

  • Rotating equipment at sand screw appropriately guarded ref. 1910.219(c)(2)(i)

  • Blender, hydration unit, and sand king caution taped off. Ref. API 5416.1.10

  • Additional Comments

Sand Kings

  • Company

  • Stairs and walkway free of clutter and undamaged. All open holes on walkways covered. All had rails are up and pinned. Ref. RP54 9.3.8, 1910.24(h)

  • Rotating equipment and belts have all guards. Ref. 1910.219(c)(2)(i)

  • Spotter located at front of sand kings to assist haulers in backing. Ref. CHK BMP

  • F.E.'s charged, inspected, and ready for service. Ref. 1910.252(a)(2)(ii)

  • Appropriate PPE worn, P-100 respirators or better. Ref. 1910.132/CHK Policy.

  • Additional Comments

Missile

  • Company

  • High pressure area only 1 CSS in are to look for leaks while testing or pumping. Ref. API 5416.1.10

  • Hoses on missile free from abrasions, gouges, and cuts. Hose rated to 250 psi with factory ends. Whip checks installed properly. Ref. RP 54 16.1.7, RP 54 9.13.3

  • All valves have handles. Ref. industry standard

  • All brackets on missile have bolts and tightened. Ref. industry standard

  • All iron on missile certified and banded within last 6 months. Ref. CHK BMP

  • Hammer unions clean and dressed free of mushrooms. Ref. RP54 12.5.1

  • All valves no in use capped. Ref. CHK BMP

  • F.E.'s charged, inspected, and ready for service. Ref. RP 54 20.3.4, 1910.252(a)(2)(ii)

  • All iron between missile and pumps certified, tested, and banded (last6 months). (Min4 chick sans) blocked under chiks. Ref. API 54 12.4.2

  • Bars available for isolation valves. Ref. CHK BMP

  • Additional Comments

Pump Trucks

  • Company

  • Wheel chokes in place. Ref. industry standard

  • F.E.'s charged, inspected and ready for service. Ref. RP 54 16.1.10

  • High pressure area only 1 SDS in area to look for leaks while testing or pumping. Caution tape up or no go zone designated. Ref. 1910.219(c)(2)(i)

  • Guards in place over transmission and drive shaft. Ref RP54 16.1.7

  • Hydraulic hoses in vicinity of turbo sheathed. BMP

  • All iron brackets in place and bolted down tightly. CHK BMP

  • All iron on pumps certified, tested, and banded in last 6 months. Ref. RP54 12.5.1

  • Hammer unions clean and dressed free of mushrooms. Ref. RP54 12.5.1

  • Bars for isolation valves readily available. Ref. CHK BMP

  • Additional Comments

Treating Iron to Well Head

  • Company

  • High pressure are only 1 CSS in area to look for leaks while testing or pumping. Caution tape up or no go zone designated. Ref. RP 54 16.1.10

  • All iron certified, tested, and banded in last 6 months. Ref. CHK BMP

  • All hammer unions dressed and ready for service. RP 54 12.5.1

  • All treating lines to well head have flapper style check valve, isolation valve, manifold or tree, and pressure recording device. Ref. RP54 16.1.4 BMP

  • All iron and chiksans and blocked to prevent digging into ground. Ref. RP54 12.4.2

  • Isolation valves have bar readily available. Ref. Industry Standard

  • 3" wheel valves have handles. Ref. BMP

  • Where treating iron crosses is the iron rubbing together. Ref CHK BMP

  • Down joints are anchored together with 10k strap. Ref. CHK BMP

  • Additional Comments

Well Head

  • Company

  • Area around hydraulic lines for BOP or hydraulic valves free of leaks. Ref. Manufacturer Recommendation

  • All valves have handles installed and number of turns to open and close on trees. Ref. BMP

  • Frac stack has platform installed or man lift on location. Ref. RP54 5.5.1

  • All flanges have all bolts and not short bolted. Ref. RP54 6.4.10

  • Cellar has been cleaned out filled in to CSG valve less than 4 ft. And properly guarded. Ref. API 54 7.1.9, API RP 54 6.7.2

  • Flow back tie in(see FB Checklist) Ref. CHK BMP

  • Hydraulic valves have 1 male and 1 female fitting. Ref. BMP

  • BOP hoses have crush proof sheaths. Ref. RP53 12.5.2

  • Frac head, hydraulic valve, BOP, and B section should be accompanied with test chart. Ref. RP 53 17.3.7

  • Additional Comments

Wireline

  • Company

  • Unit chocked, positioned 50ft. From well head, and grounded. Ref RP54 13.8.6, RP67 2.9.1, 3.7, RP54 13.2.1

  • F.E.'s charged, inspected, and ready for service. Ref. RP54 16.1.10

  • Lower wire line sheave secured to well head. Ref. RP54 13.4.5

  • Wireline BOP tested in open and closed position. Ref. RP54 13.6.2 & 13.6.3

  • Wireline unit caution taped off. Ref. RP54 12.1.7

  • Wireline personnel maintain 75 ft. Rule from wellhead when testing or pumping. Ref. RP54 16.1.10, BMP frac standard

  • Are personnel respecting radio silence. Ref RP67 2.6.2.3

  • Is warning given prior to guns being armed ballistically. Ref. 1910.109(e)(5)

  • Are wireline personnel giving Cr/Op clear signals

  • Additional Comments

Lubricator

  • Company

  • Lubricator marked with permanent serial number. Ref. RP54 13.6.5c

  • Lubricator tested, banded, and inspected on annual basis. Ref. RP54 13.6.2

  • Weight of lubricator marked on lubricator. Ref. Manufacturer Recommendation

  • Lubricator has 2 bleed valves. Ref. RP54 12.5.2

  • Personnel check for pressure prior to removing lubricator. Ref. RP 54 12.5.4

  • Lubricator bleed valves cycled after pressure bled off. Ref. RP54 12.5.11

  • Are personnel using tag lines and staying out from under suspended loads. Ref. RP54 6.2.12

  • Additional Comments

Crane

  • Company

  • Cr/Op certified and knowledgable. Ref. 1910.180(b)(3)

  • Outriggers out and pads under them. Ref. 1910.180(h)(3)(i)(a)

  • Is boom angle to great for load. Ref. 1910.180(h)(1)(i)

  • Cones out to identify swing path. Ref. 1910.180(h)(3)(iii)(b)

  • Crane is free of leaks. Ref. manufacturer recommendation

  • Cr/Op has performed daily inspection. Ref. 1910.180(d)(2)(i)

  • Annual inspection on crane is up to date. Ref. 1910.180(d)(2)(ii)

  • Cr/Op remains at controls while lubricator is unsecured. Ref. 1910.180(h)(4)(i)

  • Cr/Op understands signals given by wireline. Ref. 1926.201(b)

  • Rigging meets Crosby standards. Ref. Industry standard

  • F.E.'s charged, inspected, and ready for service. Ref. RP54 16.1.10

  • Cr/Op clear of area when testing or pumping. Ref. Rap54 16.1.10

  • Additional Comments

Closing Unit

  • Company

  • Closing unit is free of leaks. Ref. BMP

  • Connections have 1 male end & 1 female end. Ref. BMP

  • Open/Close clearly marked on handle. Ref. RP54 7.2.2, RP53 12.5.3f

  • Valve hand waits for signal before operating handle. Ref. CHK BMP

  • Closing unit 50 ft. Min. From well head. RP54 7.2.2

  • Valve hand has direct line of sight to well head. Ref. CHK BMP

  • Closing unit has crush resistant over hoses. Ref. RP53 12.5.2

  • Additional Comments

Light Plants/Generators

  • Company

  • Rig lighting and fixtures shall be of appropriate electrical classification for the area in which they are located. Ref. RP54 9.14.6, RP 500

  • Light fixtures should be placed Nd maintained to provide illumination for work areas. Ref. RP54 9.14.7

  • Light plants/generators shall be placed 100ft. From well. Ref. RP54 9.14.2

  • All electrical extension cords shall be properly insulated and plugs shall be in good condition. Ref. RP54 9.14.5

  • Light plants are grounded. Ref. RP 2003

  • Repairs shall not be made on light plants unless LOTO is performed and person is qualified. Ref. RP54 9.14.9

  • Additional Comments

Eye Wash Trailer

  • Company

  • Personnel know where eyewash trailer is located. Ref. 1910.151, Z358.1.5.4.2, RP54 4.4.1

  • Trailer clearly marked. Ref. Z358.1 5.4.3, 1910.145(c)(2)(i)

  • Tanks are full and have been tested daily. Ref. Z358.1 4.1.4

  • Generator starts on first crank. Ref. manufacturer recommendation

  • Water flows freely from eye wash and shower. Ref. Z358.1 5.1.6 & 4.1.4

  • Additional Comments

Personnel

  • All personnel on pad wearing proper PPE. Ref. CHK Policy

  • Personnel with less than 90 days e period e are assigned a mentor. Ref. RP54 6.1.7

  • Personnel H2S awareness trained. Ref. API RP 49 5.1

  • Each company on pad has JSA for their job. Ref. RP54 6.1.7

  • SIMOPS is being coordinated through Co/Man. Ref. RP54 6.1.7

  • Personnel using spotters when backing. Ref. CHK BMP

  • Personnel using tag lines. Ref. 1910.180(h)3()(vi), RP54 6.2.12

  • Crews communicating well. Ref. CHK BMP

  • All personnel sign in and out when entering/exiting pad. Ref. 1910.38(c)(4)

  • Personnel use designated smoking area. Rf. RP54 7.1.2-3

  • All personnel operating equipment are trained and certified on that equipment. Ref. manufacturer recommendation

  • General housekeeping good. Ref. RP54 6.5.1, 1910.22(a)(1)

  • Additional Comments

Chemicals

  • Company

  • Acid transport and all other tote tanks in containment. Ref. CHK BMP

  • All chemicals clearly labeled with SDS. Ref. 1910.1200(b)(1)

  • All personnel wearing proper PPE per SDS. 1910.1200(b)(i)

  • All transfer lines are fit for purpose. Ref. manufacturer recommendation

  • Acid transport grounded. Ref. RP 2003

  • Additional Comments

Fuel Trucks

  • Company

  • Discharge valves, hose, and nozzles in good condition. Nozzle equipped with auto shut off. Ref. 1910.106(b)

  • Piping and fuel lines in good condition. Ref. 1910.106(b)

  • Fuel tanks properly labeled on all sides. Ref. RP54 8.4.1d, 1910.1200(f)(4-5)

  • Fuel lines not ran under equipment when not in use. Ref. BMP

  • "No Smoking" signs erected on all sides. Ref. RP54 7.1.2-6

  • Vapor release vents elevated& away from ignition source. Ref. 1919.106(b)(2)(iv)(c)

  • General housekeeping. Ref. 1910.22(a)(1)

  • B/C class fire extinguisher available and identified. Ref. 1910.157(c)(1)

  • Splash filling prohibited.

  • Fill line & discharge velocity limited.

  • Grounded.

  • Contents on NON-FLAMMABLE storage tanks identified on all sides of tank(s). Ref. 1910.145(c)(2)(i)

  • Additional Comments

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.