Title Page
-
Conducted on
-
Prepared by
-
Location
INSPECTOR
-
WHO IS INSPECTING SUBSTATION
-
-
Add signature
OCR's AND OIL SWITCHES
-
APPEARANCE OK
-
BUSHINGS CLEAN, GOOD CONDITION
-
FREE FROM OIL LEAKS
-
COUNTER READINGS RECORDED
AIR-BREAK AND DISCONNECT SWITCHES
-
APPEARANCE OK
-
INSULATORS OK
-
GROUND CONNECTION TO HANDLE OK
BYPASS SWITCHES
-
APPEARANCE OK
-
INSULATORS OK
MISCELLANEOUS ELECTRICAL EQUIPMENT
-
ARRESTER APPEARANCE OK
-
ARRESTER CORRECTLY CONNECTED
-
SWITCH STICKS OK, PROPERLY STORED
-
PHASES PROPERLY IDENTIFIED
-
CIRCUITS PROPERLY IDENTIFIED
-
BUSES AND CONNECTIONS OK
-
BURNED OUT LAMPS REPLACED
-
OVERHEAD GROUND WIRE OK
-
CABINETS AND CUBICLES OK
SAFETY
-
EQUIPMENT GROUNDS OK
-
FENCES AND GATES GROUNDED
-
EXITS, WALKWAYS AND DRIVEWAYS CLEAR
-
SUB ENCLOSURES FREE OF STORED MATERIAL & EQUIPMENT
-
NESC CLEARANCES COMPLIED WITH
-
SUBSTATION AREA PROPERLY LIGHTED
-
YARD CLEAN AND FREE OF WEEDS
-
GATES PROPERLY LOCKED
-
SUITABLE WARNING SIGNS ON FENCES
YARD AND STRUCTURES
-
FENCES AND GATES ADEQUATE
-
YARD PROPERLY SURFACED
-
STRUCTURE PAINT OK
-
FENCE AND GATE PAINT OK
POWER TRANSORMERS
-
APPEARANCE OK
-
BUSHINGS CLEAN,GOOD CONDITION
-
OIL LEVELS AND GAUGES OK
-
FREE FROM OIL LEAKS
-
THERMOMETERS OK, MAXIMUMS RESET
-
AUX. COOLING EQUIPMENT OK
-
GAS PRESSURE OK
REGULATORS
-
APPEARANCE OK
-
BUSHINGS CLEAN, GOOD CONDTION
-
OIL LEVELS AND GAUGES OK
-
FREE FROM OIL LEAKS
-
THERMOMETERS OK, MAXIMUMS RESET
-
MECHANISMS OK
-
INDICATING LIGHTS OK
-
INDICATING GLASS COVERS INTACT
-
CABINET GASKETS WEATHER TIGHT
-
COUNTER READINGS RECORDED
ADDITIONAL COMMENTS
TRANSFORMER
UNIT 69/12.47kv
MANUFACTURE = ( VT )
SERIAL# ( 472500A025-B836A )
TAP SETTING #2 ( 70,725 )
OIL LEVEL
-
-
OIL TEMP
-
OIL PRESSURE
BUSHING CONDITION
-
BUSHING CONDITION
REGULATORS
DRAG HAND POSITIONS
A-PHASE
-
CURRENT POSITION
-
MINIMUM POSITION
-
MAXIMUM POSITION
-
NUMBER OF OPERATIONS
-
RESET DRAG HANDS
-
MAXIMUM CURRENT
-
POWER FACTOR MAX / MIN
-
KVA MAX
-
OUTPUT VOLTAGE
B-PHASE
-
CURRENT POSITION
-
MINIMUM POSITION
-
MAXIMUM POSITION
-
NUMBER OF OPERATIONS
-
RESET DRAG HANDS
-
MAXIMUM CURRENT
-
POWER FACTOR MAX / MIN
-
KVA MAX
-
OUTPUT VOLTAGE
C-PHASE
-
CURRENT POSITION
-
MINIMUM POSITION
-
MAXIMUM POSITION
-
NUMBER OF OPERATIONS
-
RESET DRAG HANDS
-
MAX CURRENT
-
POWER FACTOR MAX / MIN
-
OUTPUT VOLTAGE
REGULATOR SETTINGS
A-PHASE
-
MANUFACTURE ( SIEMENS ) SERIAL # ( 6087-55 ) TYPE / AMPS ( JFR / 100 ) SET VOLTAGE ( 122 ) BAND WIDTH 2 TIME DELAY ( 30 ) LDC R / X ( 1.9 / 0.9 ) CONTROL TYPE ( CL6B )
B-PHASE
-
MANUFACTURE (COOPER) SERIAL # ( 0037012759 ) TYPE / AMPS ( VR32 B / 150 ) SET VOLTAGE ( 124 ) BAND WIDTH 2 TIME DELAY ( 30 ) LDC R / X ( 2.8 / 1.4 ) CONTROL TYPE ( CL6B )
C-PHASE
-
MANUFACTURE (COOPER) SERIAL # ( ) TYPE / AMPS ( VR32 B / 150 ) SET VOLTAGE ( 122 ) BAND WIDTH 2 TIME DELAY ( 30 ) LDC R / X ( 1.9 / 0.9 ) CONTROL TYPE ( CL6B )
OIL CIRCUIT RECLOSERS
To find Demand metering amps. 1. Press METERING button, press down arrow to "Demand Metering", arrow down to "Reset Demand Phase Amps", press ENTER, record max demand an d peak amps below. To Reset Demand and Peak Amps 1. Press METERING button, press down arrow to "Demand Metering", arrow down to "Reset Demand Peaks", press F4. "METER ARE RESET" should appear for 2 seconds.
ROUTE No. 2 & 3
-
A- COUNTER READINGS
-
B- COUNTER READINGS
-
C- COUNTER READINGS
-
A-AMPS INSTANTANEOUS
-
B-AMPS INSTANTANEOUS
-
C-AMPS INSTANTANEOUS
ROUT No. 4
-
A- COUNTER READINGS
-
B-COUNTER READINGS
-
C-COUNTER READINGS
-
A-AMPS INSTANTANEOUS
-
B-AMPS INSTANTANEOUS
-
C-AMPS INSTANTANEOUS