Information
-
Audit Title
-
Document No.
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Slabs storage
-
Special order wood slabs are protected from dirt, dust, and damage,
-
Slabs are stored with cardboard covering them in warehouse for protection.
-
Slab area is organized and in proper bin locations.
-
Warehouse is clean and orderly.
Jamb quality inspection
-
FJ Raw Splits are clear of blow-outs, or product defect?
-
Primed Splits are of good quality with no noticeable defects?
-
Flat FJ Raw are clear of blow-outs, or visible defect?
-
Flat FJ Primed show no signs of visible defect.
-
Veneered Jambs are not showing signs of splitting or delaminating.
Casing
-
FJ Raw casing is clear of blow-outs or visible defect?
-
Primed shows no visible signs of defect?
-
Veneered is clear of splitting or bubbling in the veneer and appears to be sound?
Norfield Spec check
-
Top of door to top of hinge 6-8 7"
-
Top of door to top of middle hinge 6-8 = 36-1/4"
-
Top of door to top of bottom hinge 6-8 = 65-1/2"
-
Top of door to center of bore 6-8 = 44"
Norfield 5000
-
Any obvious issues that need to be addressed or suggestions by the operator.
-
Staples are being placed properly at head jamb, flush.
-
Nail securing unit is hitting at strike on both door and jamb, with proper exposure?
-
Casing is applied with proper number of staples per leg, head? 9 per leg.
-
Cardboard is being applied with proper number of staples?
-
Unit is being handled properly to avoid damage between shop and loading?
-
Proper information is being applied to unit for identification?
Custom Slab Line "Magnum"
-
Hinge bar stops are tight and secure.
-
Sanding wheel is properly smoothing edge of beveled slab.
-
Date last sanding wheel change?
-
Overall maintenance appears to be sufficient?
-
Any obvious issues that need to be addressed or suggestions by the operator.
-
Morticing of hinge pockets is clean and tight to hinge?
-
Date of last router bit change?
-
Bore and latch is clean and located properly?
-
Date bore bit was last replaced?
-
Date latch bit was replaced?
-
Skid feet are being applied to slab onlys.
Custom Machining Spec 7-0
-
Top of door to top of hinge 7-0 =
-
Top of door to top of middle first hinge 7-0 =
-
Top of door to top of middle second hinge 7-0 =
-
Top of door to top of bottom hinge 7-0 =
-
Top of door to center of bore 7-0 = 36"
Custom Machining Spec 8-0
-
Top of door to top of hinge 8-0 = 7"
-
Top of door to top of middle hinge 8-0 = 32-1/8"
-
Top of door to top of middle hinge 8-0 = 57-1/16"
-
Top of door to top of bottom hinge 8-0 = 82-1/16"
-
Top of door to center of bore 8-0 = 60"
Strike Jamb Router
-
Any obvious issues that need to be addressed or suggestions by the operator.
-
A full lip strike plate is within arms reach.
-
Mortised pocket is clean and burr free?
-
Date router bit last replaced?
-
Mortise pocket is proper depth?
-
Mortise Pocket is positioned correctly from top of jamb? From top of dado 44-1/4".
-
Mortise pocket is positioned correctly from stop?
Heads
-
Random pulled heads are cut to call size? (check a minimum 10)
Single Completed Units
-
Good overall appearance.
-
Exposed staples in jamb face?
-
Cardboard bottom stapled only to jamb, Not slab.
-
Adequate staples on top cardboard.
-
Bottom skid trim only one staple per jamb.
-
Length of staple being used for bottom skid trim.
Double Units
-
T-Ast properly applied?
-
Head & foot bolt properly seated in T-ast.
-
Cardboard bottom stapled only to jamb, Not slab.
-
Adequate staples on top cardboard.
-
Bottom skid trim only one staple per jamb.
-
Length of staple being used for bottom skid trim.
Shop Appearance
-
Last sweeping of shop
-
Shop area.
-
Last trash removal.
-
Trash cans