Disrepair
-
Is the kitchen beyond practical/economical repair?
Electrical Hazards
-
Is there a socket or switch within arm's reach of sink?
-
Are there any other hazards which could lead to electrocution?
Fire Hazards
-
Is there a socket or switch within 150mm of cooker space?
-
Is there a wall/tall unit within 150mm of cooker space?
-
Is the cooker within 900mm of a window/opening?
-
Is there inadequate smoke/heat detection?
-
Are there any other hazards which could lead to fire or burns/scalds?
Layout Hazards
-
Is there less than 500mm of worktop either side of the cooker space?
-
Is there less than 400mm of worktop either side of the sink?
-
Is the floor space between opposing base units less than 1200mm?
-
Is there a wall unit above the sink or with no worktop below?
-
Are there any other hazards caused by poor layout/design?
Ventilation
-
Is there no extraction present?
-
Are there any other ventilation issues?
Hygiene
-
Are the worktops unsuitable for the preparation of food?
-
Is there any evidence of damp (including mould growth)?
-
Is there any evidence of pests/infestation?
-
Are there any other Health risks from poor design/layout/condition?
Water Supply
-
Is the hot water supply inadequate?
-
Is the cold water supply inadequate?
-
Are there any lead water pipes present?
Other Hazards
-
Are there any suspected Asbestos Containing Materials present?
-
Are there any trip hazards or risk of collisions?
-
Is the lighting provision inadequate?
Capacity
-
Is there insufficient storage? (See tables overleaf)
-
Is the worktop insufficient? (1200mm for 1-2 beds, 1600mm for 3-5)
-
Are there insufficient sockets? (10 is optimal where possible)
Surveyor's Recommendations
-
What work is required to bring the kitchen up to a Decent Standard? i.e if you have ticked "Yes" in any of the boxes above, what work is required to rectify the problem?