Title Page
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
The Base of the Scaffold
-
Does the scaffold have a tag on that is in date (within the last 7 days)
-
Has the area where the scaffold is being erected been segregated/barriered off
-
You MUST NOT access the scaffold until you can confirm via a scaffold register that the scaffold has been inspected and is safe to use.
-
Is there a red - DO NOT USE SCAFFOLD tag showing
-
Are there sole boards in place under all legs where required?
-
Are the sole boards in good condition
-
Can the Base jacks be adjusted easily?
-
Are transoms present on the bottom 'V' pressings
-
Are the wedges present and driven home correctly
-
Are the ledgers present and fitted correctly
-
Is the base 'Square'
-
Has the base platform (Steelstage) been erected correctly
-
Is the base platform in good condition
The Scaffold
-
Are the diagonal braces fitted on the outside of the standards
-
Has the working platform (Steelstage) been erected correctly
-
Has Edge protection been installed? (This can be either Kwikguard or Steelstage)
-
Are guardrails fitted correctly
-
Are ladders in good condition
-
Where ladders are used to access the scaffold from the base do they reach a minimum of 1m above the working platform
-
Are base ladders correctly tied off
-
Having completed the audit would you deem the scaffold safe to use?
Additional Media/Comments
-
Comments
-
Media
SIGN OFF
-
Signature
-
Date/Time