Title Page
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
PRE SITE
-
Pre site safety checklist completed
-
Circuits arranged to suit reasonable maximum demand
NBN AND STRUCTURED CABLE
-
NBN GPO wired to NBN (Carlisle & Fairhaven)
-
TV roof coils at correct location (manhole or NBN board for opticom estate)
-
Maintained separation of structured cables from electrical cables
-
Maintained desperation of structured cables from electrical cables, multiple
SWITCHBOARD
-
Feeds/mains in switchboard
-
Feeds/mains segregated from gas and water pipes
-
Switchboard cable entry ‘slide & cover’ reinstalled
-
Pole fillers reinstalled
-
Earth bond connected and zinc sprayed
-
Subboard locates as per plan
-
Measurements for subboard notes on plan
-
Correct sub mains ran, ie, 1 or 3 phase
-
Correct cable sizes used for AC and seperate circuits
WALLS
-
All brackets installed
-
Cables easily accessible at brackets. Ie, not knocked down
-
Cables easily accessible at brackets. Multiple
-
N/C measurements on plan
-
Garage wall measurements on plan
-
All switchlines labelled
-
All items as per plan
-
All heights as per plan
-
Client / plan specific measurements followed
-
GPOs in wet areas at minimum height and distance
-
WM GPO as per plan and REGULATIONS
-
Bathroom / en-suite GPO loop measurements on plan
-
Bathroom / en-suite switch height allowed for towel rail
-
Cables clear of return air void
-
Holes drilled in brace board, maximum 100mm
-
Holes drilled in walls and top plates, min 300mm apart
-
Holes drilled in walls and top plates, min 300mm apart. More than 1
-
Holes drilled in walls and top plates, min 300mm apart, 3 or more
-
Holes 300mm from bracing
-
Holes 300mm from bracing. More than 1
-
Holes 300mm from bracing. 3 or more
-
25mm segregation from pipes
-
25mm segregation from pipes. More than 1
-
25mm segregation from pipes. 3 or more
-
Oven & cooktop wired correctly. Ie, upright/ wall oven/ induction
-
Island bench power ran and in corrugated conduit
-
Kitchen measurements correct and noted on plan
-
Rangehood nogged or timber in space
ROOF / LIGHTS
-
All light measurements on plan
-
Light measurements clear of pipes, ducting, tv and data
-
Step lights single end location noted on plan
-
Kitchen strip light / under cupboard lights roughed in correctly. Location and accessibility of cables
-
2 ways / 3 ways ran correctly
-
Smoke detector located as per regs
-
Smoke detectors interconnected
-
Cables securely supported on trusses
-
Cables securely supported on trusses. Multiple
-
Switchlines clipped in line with mark
-
Switchlines clipped in line with mark. Multiple
-
Switching of lights roughed in as per plan
-
In roof JBs fit off at rough in and noted on plan
-
Pendant and fan nogs installed
-
Plug bases and quick connects fit off
-
Correct exhaust fan and tastic measurements
-
Exhaust fans and tastics clear of obstructions
-
Exhaust fans, tastic and rangehood ducted
-
Roof work in correct locations
-
Roof work locations marked on plan
-
Roof work fit off at rough in
-
Holes drilled <300mm apart in joists
-
Holes drilled <300mm apart in joists. More than 1
-
Holes drilled <300mm apart in joist. 3 or more
OUTSIDE
-
Externals through brickwork / hebel
-
Externals heights as per plan
-
Clear of downpipes
-
Clear of downpipes. Multiple
-
HWS GPO in correct locational
-
AC isolator in correct location
-
External vents brought through brickwork / hebel if complete. Measurements provided if not.
-
Electrical items 1000mm clear of gas pipe
POST INSULATION
-
Insulation installed upstairs ceiling
-
Insulation installed downstairs ceiling
-
If plaster battens installed, are they clear of light measurements?
-
Insulation clearance for exhaust fans and tastics
-
Clipping to location between trusses (lines up with mark)
-
N/C measurements still clipped to mark
-
GPO loops in wall placed infront of wall batts
-
Wall lights placed infront of wall batts
-
Heater and light fit off
-
EVAP fit off
-
Owners cable added
-
Nogs installed and cable poked through in rooms with BH deemed inaccessible
-
Items that require attention due to insulation installers
POST SITE
-
Site has been swept up and rubbish put in bin
-
Detailed unfinished report completed
-
Moved items on unfinished report