Information

  • Survey Title

  • Client

  • Site Address

  • Lift number:

  • Survey Conducted On:

  • Survey Conducted By:

  • Report Date:

Lift Details

Lift details

  • Lift Manufacturer

  • Maximum persons

  • Maximum load kgs

  • Speed M/S

  • Usage level

  • Drive type

  • Motor room location

  • Installation date

  • Modernisation date

  • Number of floors served

  • No of car entrances

  • No of landing entrances

  • Floors served front

  • Floors served rear

  • Floors served left hand side

  • Floors served right hand side

  • Shaft width mm

  • Shaft depth mm

  • Pit depth mm

  • Headroom mm

  • Travel mm

  • Summary Report

  • Recommended health and safety works

  • Recommended DDA upgrade works

  • Recommended upgrade / replacement works

Lif Motor Room

Motor Room

  • Is the motor room access safe with suitable lighting and emergency lighting and any access ladders over 2M in height fitted with hooped protection?

  • Is the motor room door lockable and fitted with an internal release and displaying current motor room entrance notices?

  • Are any trap doors of sound construction, counterbalanced and marked with the safe working load?

  • Does the motor lighting meet current standards (200 lux at floor level)?

  • Is emergency lighting fitted and working correctly?

  • Is the motor room light switch fitted adjacent to the motor main entry point and clearly identified?

  • Can the lift car lighting be isolated within the motor room / control panel (MRL)

  • Is the mains isolator lockable?

  • Main isolator rating (amps)

  • Compliant consumer unit fitted within the motor room?

  • Is a RCD Protected 240V socket available in the motor room?

  • Is an electric shock notice displayed within the motor room, is this securely fixed using mechanical (screw) fixings

  • Are handwinding instructions displayed within the motor room, are these securely fixed and comply with the hand lowering procedure for the lift?

  • Is a floor level indicator fitted with both audible and visual indication including the ability to identify the lift location (lifts serving more than two floors)

  • Is there a rubber mat fitted in front and rear where applicable of the control panel and any other electrical panels within the motor room?

  • In a shared motor room is the lift number clearly identified on each piece of plant I.e. control panel, gear, isolator, overspeed governor.

  • Is there a tool board fitted?

  • Are all lifting beams within the motor room tested and marked with the safe working load?

  • Are the motor room and plinth floors free of tripping and slipping hazards and any redundant holes blanked off?

  • Are there a guard rails and access ladder fitted were plinths are more than 500mm high, do these comply with current standards and suitably fixed?

  • Is there a phone line available in the motor room?

  • Is there a connection to the fire alarm system available within the motor room?

  • Are there any none lift services in the motor room?

  • Is the motor room in a clean and tidy condition?

  • Is the motor room decorated?

  • Is the ambient temperature of the motor room between 15 - 25 degrees C

  • Motor room comments

Control Panel

Control Panel

  • Control panel manufacturer

  • Control panel age

  • Is there a high voltage warning notice fitted to the control panel door and heat notices were resistor boxes are externally mounted?

  • Control panel condition

  • Is the control panel of an obsolete design

  • Control panel mounted

  • Is the control panel correctly located with sufficient space to allow clear access and the panel securely fixed?

  • Control Panel Type

  • Control Type

  • Microprocessor manufacturer and type

  • VF Drive Manufacturer and Type

  • Are wiring diagrams available on site?

  • Ellison type overload device fitted?

  • Control panel comments

Hydraulic Drive Unit

Hydraulic Drive System

  • Tank manufacturer

  • Valve block manufacturer

  • Valve block details

  • Is the valve block of an obsolete design?

  • Is there an hand pump fitted to the tank?

  • Is a pressure gauge fitted?

  • Valve block leaks? - test by closing gate valve and monitor pressure drop

  • Tank condition

  • Pipework type

  • Low pressure switch

  • High Pressure switch

  • Load weighing pressure switch

  • Is an oil cooler fitted?

  • Is an oil containment system fitted?

  • Is a tank heater fitted?

  • Is motor room heating fitted?

  • Hydraulic Drive System Comments

Traction Drive System

Traction Machine

  • Motor manufacturer

  • Motor condition

  • Motor HP/ Kw

  • Motor amps

  • Gear unit manufacturer

  • Gear condition

  • Brake manufacturer

  • Brake condition

  • Sheave size mm

  • Sheave condition

  • Are anti-jump bars fitted to the traction machine to prevent the main hoisting ropes from coming off the sheave?

  • Winding wheel available?

  • Tachometer fitted for motor feedback to VF drive?

  • Does the machine run without any undue noise or vibration

  • Number of ropes/chains and size I.e. 4 x 13mm

  • Divertor location

  • Is there an emergency stop switch fitted adjacent to the hoisting machine?

  • Is guarding fitted to the hoisting machine to protect against all moving parts?

  • Can any guarding to items required to facilitate emergency release be removed without the use of tools?

  • Are all rotating parts painted yellow?

  • Traction Machine Comments

Overspeed Governor

Overspeed Governor

  • Overspeed governor location

  • Is guarding fitted to the overspeed governor?

  • Electrical tripping speed (m/s)

  • Mechanical tripping speed (m/s)

  • Overspeed governor comments

Entrances

Entrances

  • Door manufacturer

  • Door operator type

  • Door equipment condition

  • Door protection

  • Car door type

  • Landing door type

  • Door width (mm clear opening)

  • Door height (mm clear opening)

  • Door finish - lift car

  • Door finish - landings

  • Landing architrave type

  • Landing architraves finish

  • Door operation

  • Zone locking fitted

  • Door cill condition

  • Door running equipment condition

  • Door closing device

  • Are shaft fascia's fitted and secure?

  • Are landing toe guards fitted and secure?

  • Is there a toe guard fitted to the lift car?

  • Is pre-locking fitted to manually operated gates?

  • Are the clearance on all entrances less than 6mm (10mm when original equipment retained)?

  • Are there any excessive forced gaps on the car and landings entrances?

  • Is a landing entrance barrier provided?

  • Entrances comments

Landing Stations

Landing pushes and indicators

  • Landing push finish

  • Landing station mounted

  • Landing station lowest button (mm)

  • Landing station highest button (mm)

  • Landing indicator finish

  • Landing indicator mounted

  • Landing indicator type

  • Landing at floors

  • Has signage been displayed at each each landing warning against the use of the lift in the event of fire?

  • Is there a fire recall device fitted?

  • Landing station comments

Landing DDA Compliance

  • Landing station height and position correct?

  • Are Braille / tactile buttons fitted?

  • Is audible call acceptance fitted?

  • Is visual call acceptance fitted?

  • Are landing indicators fitted (above 2 floors)?

  • Are hall lanterns fitted (above 2 floors)?

  • Have tactile floor ID plates been fitted at all floors?

  • Is an arrival gong fitted?

Lift Car

Lift Car

  • Car width (mm)

  • Car depth (mm)

  • Car height (mm)

  • Car wall finishes

  • Car ceiling finishes

  • Car floor finishes

  • Are bump rails fitted within the lift car?

  • Lift car lighting type

  • Lift car lighting mounting

  • Emergency lighting working

  • Car station location

  • Distance to nearest corner (mm)

  • Height lowest button (mm)

  • Height highest button (mm)

  • Number of key switches fitted?

  • Key switches operate?

  • Is car lighting fitted as specified, providing a minimum of 200lux at floor level?

  • Is the emergency lighting fitted as specified and working correctly?

  • Does the audible alarm operate correctly under both power on and power off conditions?

  • Is the emergency two way communications system fitted and operating correctly?

  • Lift Car Comments

Lift Car DDA Compliance

  • Entrance size and type?

  • Car station height and position correct?

  • Are Braille / tactile buttons fitted?

  • Is audible call acceptance fitted?

  • Is visual call acceptance fitted?

  • Visual floor identification fitted (above 2 floors)?

  • Audible floor identification fitted (above 2 floors)?

  • Autodialler and acoustic loop or emergency call system fitted? i.e. wardens call

  • Handrail fitted in the lift car?

  • Mirror fitted in the lift car?

  • Car lighting a minimum of 100 lux at floor level?

  • Are infra-red full height safety edges fitted?

Car Top

Car Top

  • Shaft selector type

  • Is a up inspection limit fitted?

  • Is a car top control conforming to either EN81- 1/2 or BS7255 enhanced version fitted?

  • Is a run (common) button fitted

  • Is an emergency stop switch located with 1 metre of the landing threshold?

  • Is a car top light fitted, did it operate correctly at the time of survey?

  • is emergency lighting fitted to the car top?

  • Is a RCD protected socket fitted?

  • Is a car top emergency communication device fitted?

  • Are all pulleys on the car top painted yellow and guarded?

  • Are there any voids around the top of the lift car in excess of 300mm?

  • Where voids exceed 300mm is a securely fixed and rigid car top balustrade fitted complete with mid bar and toe board?

  • Car Top Comments

Lift Shaft

Lift Shaft

  • What are the shaft walls constructed in?

  • What are the door nibs constructed in?

  • What is the shaft roof constructed in?

  • What is the lift pit constructed from?

  • Is the well enclosure continuous floor to ceiling?

  • Is the shaft painted / dust sealed?

  • Are full height division screens fitted where the shaft is shared with other lifts?

  • Are there lifting beams or lifting points fitted and are these marked with the safe working load?

  • Is the shaft lighting fitted?

  • Are there any non-lift services within the lift shaft?

  • Is a restricted headroom notice fitted where applicable?

Lift Pit

Lift Pit

  • Number of buffers fitted

  • Type of buffers fitted

  • Is there a suitable access ladder to allow safe access and egress to and from the pit area?

  • Is the pit stop switch(es) easily accessible form both the pit and landing?

  • Can the shaft lighting be switched on/ off from the lift pit?

  • Is there a 240v pit socket fitted?

  • On traction lifts is a counterweight screen which extend to an height of 2.5M from the pit floor fitted?

  • Are pit division screens fitted up to an height of 2.5M where the lift shares a shaft?

  • Is the pit clear of any water or oil?

  • on hydraulic lifts are lifts with shallow pit depths, is a mechanical restraint provided?

  • Is the mechanical restraint electrically interlocked?

  • On shallow pits, is a restricted pit depth notice displayed?

  • Was the pit found in a clean condition and free of rubbish?

  • Are drip trays fitted to the base of the car and counterweight guides?

  • Is the overspeed governor return pulley electrically switched?

  • Is the overspeed governor return pulley guarded?

  • Is there a compensation rope/chain pulley fitted?

  • Is the compensation rope/chain pulley electrically interlocked?

  • Lift Pit Comments

Car Sling

Car Sling

  • Type of safety gear fitted

  • Is the safety gear electrically switched?

  • Type of guide shoes fitted

  • Are compensating ropes/chains fitted to the lift car?

  • Type of compensation fitted

  • Sling comments

Hydraulic Cylinder

Hydraulic Cylinder

  • Number of hydraulic rams fitted?

  • Hydraulic ram type?

  • Hydraulic arrangement

  • Number of ropes/chains and size I.e. 4 x 13mm

  • Ram seal condition

  • Rupture valve fitted?

  • Overflow bottle and hose fitted?

  • Hydraulic cylinder comments

Counterweight

Counterweight

  • Counterweight type

  • Type of guide shoes fitted

  • Type of filler weights fitted

  • Are the filler secured within the counterweight?

  • Is there a divertor pulley fitted to the counterweight?

  • Is the counterweight pulley guarded?

  • Is the counterweight painted yellow?

  • Counterweight comments

Maintenace

Lift Maintenance and Breakdowns

  • Is a current log card available?

  • Maintenance level

  • Number of maintenance visits completed in the last twelve months

  • Comments on maintenance

  • Number of breakdowns in the last twelve months

  • Comments on lift breakdowns

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.