Safety Procedures

  • Has an Hazard Assessment been done for this activity?

  • Has a Pre-work Safety meeting been done on site?

  • Are all PPE being used for the activity?

  • Are all workers aware of known hazards?

Traffic Management

  • Is the traffic management plan being followed?

  • Has the signs and stands been checked? ( cleanliness,visibility and stands secure)

  • Is there a need to adjust the Traffic plan? ( traffic queue length, safety hazards to TCP)

  • Are the road plate effective? (Movement, drifting, anchorage and hazards)

  • Are the speed signs working and effective?

  • Is the Changeable Message Boards visible and effective? (Message relevant to activity, all letters working)

Survey/Layout Conformance

  • Has the deck cuts been done as per the plan?<br>400mm +/- from edge of seal<br>Cut depth 38mm

  • Is the new armour centred as per the plan 0788-101?<br>Gap for a Watson Bowman Compression Seal WA-350.<br>

  • Is the Compression seal gap set at 57mm between the north armour plate and 32mm on the south armour plate?<br>Depth of seal is 4 mm below top of steel armour.

  • Is the armour set below the concrete by 6 mm?<br>Check curb area for inset.<br>

  • Has the rebar been laid out 300mm in the abutment?

  • Has the stirrups on the deck been laid out at 150mm as per the plan?

Materials Conformance

  • Has the welding been done by a CWB certified welder?<br>Get a photocopy at start of job

  • Are the Mill Certifications supplied with the Joint Armour?<br>12.7mm x 152mm plate<br>16mm x 150mm Nelson Studs at 150mm c/c

  • Does the steel conform to the drawing 0788-101, 0788-102?<br>12.7 mm x 152 mm plate.<br>16mm x 150mm Nelson Studs @ 150mm c/c<br>G40.21 grade 300 W

  • Does the rubber Compression seal comply with drawing 0788-101, 0788-102?<br>Keep the edge of the seal clean from contamination.<br>Check date of adhesion Lubricant for expiry date.<br>No visible tears or kinks.

  • Is the rebar as per drawing 0788-101, 0788-102?<br>15M bar on abutment<br>10M Stirrup on deck<br>Check over laps on horizontal bar 480mm minimal<br>G30.18M Grade 400W

  • Is the dowel hole grout checked for expiry dates?<br>Check shelf life on manufacturer specs.<br>Check bags for date stamp

  • Is the concrete conforming with spec on drawing 0788-102?<br>45 MPA after 28 days.<br>Must meet MOTI spec 211<br>Mix design passed by Ministry.

Joint Installation

  • Did the removal of the deck joint concrete damage the remaining concrete?<br>Look for cracks under the deck or road surface.

  • Do the dowel holes meet the spec of the grout being used?<br>Embedment 250mm<br>Hole size 20mm+/-<br>Hilti-HY 200 is 250 embedment

  • Is there minimum 50mm cover on all rebar?<br>Check as armour is set.<br>Check on forms.

  • Does the joint armour fit and the correct height with the existing deck?<br>Use a straightedge off the existing deck.<br>Pay attention to the curbs and sidewalks.

  • Has the concrete been poured quickly and a quality finish?<br>Good vibration<br>No honey comb after stripping

  • Has the armour galvanizing been protected from damage and protected during the concrete pour?<br>Cover the top with 6mm plywood and duck tape.

  • Has the concrete been covered with burlap and moistened with water after initial set?<br>Protect from the elements for 48 hours.<br>

  • Has the concrete been tested by local testing company?<br>Get a copy of the tests<br>Remove the plates after 24 MPA tests

  • Has care been taken during the movement and anchoring of the road plates?<br>Do not hit the wet concrete after pouring<br>Make sure they are anchored as per the drawing

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.