Site Inspection (mains)

  • Is breathing apparatus out ready for use and in date?

  • Are fire suits, gauntlets and balaclavas available for all operatives?

  • Are the current works subject to an RO/SRO/NRO?

  • If subject to one of the above procedures is the paperwork available and in date?

  • Has the procedure been authorised and cleared to proceed?

  • Have Network Control been notified by the competent person?

  • Has the pre start been completed and signed

  • Is the competent person on site?

  • Does the procedure mirror site conditions and operations? If not work is to stop as soon as the operation allows and the authorising engineer is to be notified immediately

  • Are any permits to work in place or required?

  • Are permits being adhered to?

  • Are all permits to work signed by all parties and in date?

Mains construction - open cut

  • Is the lay method open cut?

  • If open cut is the depth of cover sufficient?

  • Is the trench width sufficient for the size of main being layed?

  • Are alignment clamps available?

  • Evidence that clamps have been used?

Mains construction - live insertion

  • Is the lay method live insertion?

  • Has the host main been subject to a camera survey?

  • Are all fittings (gland box, end seal, insertion seal etc) in date and in original packaging?

  • Are excavations of a sufficient size to carry out the operation correctly?

  • Is the host main clear of any obstructions?

  • Has the host main been supported? (check there are no joints within the excavation)

Mains Construction - Dead Insertion

  • Is the lay method dead insertion?

  • Are trumpets available to minimise damage to the new main?

  • Is there sufficient clearance to complete the operation?

  • Has a decay test been undertaken?

  • Are alignment clamps available?

  • Evidence that clamps have been used (add photos where possible)

Butt fusion

  • is all plant within date and calibrated

  • Is butt fusion being carried out?

  • Butt fusion carried out correctly and cooling times observed?

PE construction

  • Is all PE pipe stored correctly and free from damage

  • Is electrofusion being carried out?

  • Electrofusion fittings kept in original packaging until point of use?

  • Pipe scraped and clear of contamination?

  • Fusion cycles complete and cooling times observed?

  • Alignment clamps marked and fusion times written on fitting or pipe?

  • EUSR number recorded on fitting or pipe?

  • Is test equipment available / in use?

  • Has flow stop equipment been installed as per SGN work procedure?

  • Have the correct distance between fittings etc been applied?

  • Have squeeze off's been applied to any section of main?

  • Has the pipe been rerounded and tape applied?

  • Has the RO/NRO/SRO been closed with Network Control and the authorising engineer?

Additional comments

  • undefined

Sign off

  • Inspector

  • Time and date

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.