Title Page
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
-
Weather
General Inspection
-
General Site Conditions
- Good
- Fair
- Poor
- N/A
-
Recommended Actions
-
Is the system powered on?
-
Describe system condition
-
Is the inverter indicating any ground faults or other error messages?
-
error code
-
Type of mounting system
-
Confirm presence of product documentation
Modules
-
Visually inspect for damage, dirt or dust accumulations
-
Check for shading
-
Results of module hand lift test
-
Describe results
Racking System
-
Visually inspect connections
-
Violations found?
-
Describe violations
-
Are footings, support structure, and all penetrations sufficiently flashed and waterproofed?
Inverters
-
Visually inspect for damage
-
Clean out interior
-
Are there air filters?
-
Did you clean them?
-
Are there fuses in the inverter?
-
Spare Fuses onsite
-
Recommend ordering replacement
-
Did you check all fuses for continuity?
-
Why not?
-
Check connections for proper torque
-
Describe actions taken
Module to Module Wiring
-
Visually inspect wiring
-
Violations Found?
-
Describe Violations
-
Violations Repaired Onsite?
-
Recommended Actions
-
Visually Inspect Connectors
-
Describe Findings
-
Spot check several module connectors for oxidation
-
Action Required
-
Repaired onsite?
-
Recommended Actions
DC/AC Combiners and Disconnects
-
Visually Inspect for damage
-
Clean out interior
-
Check all fuses
-
replace as required
-
Fuses available onsite?
-
Check Connections
-
Re-torque as needed
Monitoring
-
Does System have remote monitoring?
-
What type of monitoring does it have?
-
Do we have log in access to it?
-
What is the password?
-
What type of devices does the system have? (i.e. irradiance sensor, temp sensor, etc.)
-
Are devices operating and in good condition?
-
explain
Point of Solar System Interconnection
-
Electrical Concerns or Code Violations?
-
Inspect ground connection, retorque as needed
-
Check for cable conditions
-
Check cable terminals for burnt marks, hot spots, or loose conditions
-
Check for physical damage
Conduit and Wiring
-
Visually inspect all conduit and connections
-
Can repairs be made at visit?
-
Describe required actions
-
All conduit penetrations and roof safety anchors properly sealed with exterior grade sealant?
-
All roof mounted junction boxes, combiners securely installed?
-
Are conduit supports rated for the installation and properly installed?
-
Are conductors loose, touching roof surface or in contact with sharp or abrasive surfaces?
-
Are any conductors exposed to UV?
Thermal Imaging
-
Point of Interconnection
-
Inverters
-
AC/DC Combiner Panels
-
Disconnects
-
Misc.
Electrical Performance Test
Strings
-
Record time and ambient temperature
-
Perform and record Open Circuit Voltage Test (Voc) on all strings
-
Perform and record Maximum Power Current Test (Imp) on all strings
-
Record Irradiance on every string
Inverter
-
Perform and record anti islanding test
-
Test results documented?
-
Record inverter operating parameters:
-
DC input parameter
-
AC output parameter
-
Faults recorded?
General Comments
-
undefined