Information
Information
-
OSSM File Number
-
Property Owner/s
-
Property Address
-
Lot
-
DP
-
Number of bathrooms
-
Number of bedrooms
-
Water source
Summary
-
Date and Time at start of inspection
-
Reason for Inspection
- Renewal inspection
- Re-inspection - Follow up
- Inspection prior to Penalty Infringement Notice
- Initial approval to operate
-
System Type
- Septic Tank
- Trench
- Pump out
- AWTS
- Spray Irrigation
- Sub- surface Irrigation
- Greywater (laundry water)
- Biological Filtration System
- composting Toilets
- Ecomax
- Mound
-
Risk Ranking
-
Inspection Result
- 4 year approval
- 1 year approval
- FAIL - DEFECTIVE
-
Inspecting Officer
- Brayden Stratford
- Alan Karton
- Mitchell Golding
-
Conditions for defective letter
- 1. Warning signs must be installed on the property.
- 2. Submit a plan to Council for a second irrigation area. Primary and secondary effluent disposal areas should be established etc
- 3. The application area must be sited at least 6 metres from down gradient boundary, 15 metres from the dwelling etc
- 4. Surface spray irrigation must not be used on fruit trees and vegetable plants.
- 5. All irrigation lines must be laid underground with a minimum 100mm ground cover.
- 6. Sprinklers must be attached to the irrigation line that throw no more than 2 metres and produce coarse droplets with a maximum plume height of 400mm above finished ground level.
- 7. The irrigation area must be away from recreation areas
- 8. Al pipework and fittings must comply with all parts of AS 1477
- 9. Instal additional sprinklers in the irrigation area.
- 10. Relace the inspection cap to prevent stormwater ingress and vermin from entering the tank and breeding.
- 11. Ensure that all sprinklers used for irrigation of treated effluent are purple.
- 12. Ensure that all hose on the ground surface used for irrigation of treated effluent is purple.
- 13. Slash and remove cut grass from the effluent disposal area.
- 14. The septic tank needs to be de-sludged.
- 15. Provide a dedicated area free from livestock for the absorption trench.
- 16. To help ensure the efficient operation of your system the following additional actions are recommended:
-
Comments
Inspection Details
-
PHOTO OF SEPTIC TANK
-
PHOTO OF DISPOSAL AREA
-
System Type
Type of System
-
What type of system
- AWTS
- septic tank & trench
- Pump out
- Ecomax
- Composting Toilet
- Biolytix
-
If there is a grease trap, is it satisfactory?
-
Is the lid, manhole and inspection caps undamaged and in place?
-
Is the tank undamaged?
-
Is the tank accessible?
-
Sludge levels acceptable? Does not need a clean out
-
Does the system have quarterly maintenance by a service contractor?
-
Have service reports been sent to Council?
-
Is the system operational at the time of inspection? <br>Eg - chlorine tablets, UV lamp
-
Is the AWTS connected to a permanent/hard wired power supply, which is buried to the tanks?
-
Is the irrigation line buried?
-
No garden hoses and fittings being used for irrigation?
-
Are standard irrigation warning signs present (green background with black or white writing)?
-
Is there sufficient irrigation area?
-
Is effluent being evenly distributed?
-
sprinklers are not being used directly to irrigate fruit trees or vegetables?
-
Is the effluent disposal area greater than 15 m to dwellings?
-
Is the effluent disposal area greater than 6 m up/3m down to driveways & property boundaries?
-
Is the effluent disposal area greater than 3 m to paths and walkways?
-
Is the effluent disposal area greater than 6 m to swimming pools?
-
Is the surface drip or trickle irrigation area greater than 6 m up gradient/ 3 m down gradient to pools, property boundaries, driveways & buildings?
-
Is the lid, manhole and inspection caps undamaged and in place?
-
Is the tank undamaged?
-
Is the tank accessible?
-
Sludge levels acceptable? Does not need a clean out.
-
Is trench performing ok?
-
Is greywater being disposed of satisfactorily?
-
If there is a grease trap, is it satisfactory?
-
Is the absorption system greater than 12 m if up gradient or 6m if down gradient to the property boundary?
-
Is the effluent disposal area greater than 6 m up/ 3 m down to pools, driveways and buildings?
-
Is the absorption area adequately isolated from livestock?
-
Is there a pump-out contract?
-
Are there maintenance records kept onsite?
-
Does the operator have pump-out receipts?
-
Tank is not surcharging or overflowing?
-
Are the lid, manhole and inspection caps undamaged and in place?
-
Is the tank undamaged?
-
is there a high level alarm?
-
If the pipe to mains is visible, is it cream coloured or have a cream stripe?
-
Is greywater being disposed of satisfactorily?
-
Is there a draw line with a cam lock?
-
If there is a grease trap, is it satisfactory?
-
Is the mound dry and appear to be operating ok?
-
Are the diverter and monitoring bore accessible?
-
Is stormwater diverted away from the mound?
-
Is the lid, manhole and inspection caps undamaged and in place?
-
Is the tank undamaged?
-
Is the tank accessible?
-
Sludge levels acceptable? Does not need a clean out.
-
Is greywater being disposed of satisfactorily?
-
If there is a grease trap, is it satisfactory?
-
Is the absorption system greater than 6m if up gradient/3m if down gradient of swimming pools, driveways and buildings?
-
Is the absorption system greater than 12 m if up gradient/6m if down gradient to the property boundary?
-
Is the absorption area adequately isolated from livestock?
-
Is there an external door, shute to collect the humus?
-
Does the fan operate continuously?
-
Is the compost humus used in an environmentally safe manner?
-
Does the system appear to not require attention?
-
Is greywater being disposed of satisfactorily?
-
Is the grease trap working efficiently?
-
Is the lid, manhole and inspection caps undamaged and in place?
-
Is the tank undamaged?
-
Is the tank accessible?
-
Sludge levels acceptable? Does not need a clean out.
-
Have service reports been sent to Council?
-
Does the system have maintenance by a service contractor?
-
Is greywater being disposed of satisfactorily?
-
Is the absorption system greater than 6m if up gradient/3m if down gradient of swimming pools, driveways and buildings?
-
Is the absorption system greater than 12 m if up gradient/6m if down gradient to the property boundary?
-
Is the absorption area adequately isolated from livestock?
-
Buffer distances
-
Is the effluent disposal area greater than 100 m to permanent surface waters?
-
Is the effluent disposal area greater than 250 m to domestic groundwater?
-
Is the effluent disposal area greater than 40 m to other waters (eg intermittent waterways, dams)?
Soil
-
What basic soil type is present (if known)?
- Clay
- Loam
- Sand
- Shallow Bedrock
- Unknown
Site Specific Issues
-
Does the site have any site specific issues? eg. Surface rock, light access/evaporation potential, steep slope >15%, heavy clays, small lot with limited on site capacity, other (specify)
Performance
-
Does the system comply with the performance standards?
-
Does the system prevent the spread of disease by micro-organisms?
-
Does the system prevent the spread of foul odours?
-
Does the system prevent the contamination of water?
-
Does the system prevent the degradation of soil and vegetation?
-
Does the system discourage insects and vermin?
-
Does the system minimise any adverse impacts on the amenity of the premises and surrounding lands?
-
Does the systems provide for the re-use of resources (including nutrients, organic matter and water?
Risk Assessment
-
Hydraulic Loading
-
Vegetation Cover
-
Soil type
-
Distance to watercourse
-
Distance to drains
-
Distance to neighbours
-
Surface effluent / waterlogging
-
Migration of "wet areas" off site
-
Presence of odours
-
Servicing / maintenance
-
Occupiers knowledge of system
Overall Risk Ranking
Comments
-
undefined
-
Site Plan - All On-site Effluent System Components Identified
-
Signature