Information

Information

  • OSSM File Number

  • Property Address

  • Lot

  • DP

  • Number of bathrooms

  • Number of bedrooms

  • Water source

Summary

  • Date and Time at start of inspection

  • Reason for Inspection

  • System Type

  • Risk Ranking

  • Inspection Result

  • Conditions for defective letter

  • Comments

Inspection Details

  • PHOTO OF SEPTIC TANK

  • PHOTO OF DISPOSAL AREA

  • System Type

Type of System

  • What type of system

  • If there is a grease trap, is it satisfactory?

  • Is the lid, manhole and inspection caps undamaged and in place?

  • Is the tank undamaged?

  • Is the tank accessible?

  • Sludge levels acceptable? Does not need a clean out

  • Does the system have quarterly maintenance by a service contractor?

  • Have service reports been sent to Council?

  • Is the system operational at the time of inspection? <br>Eg - chlorine tablets, UV lamp

  • Is the AWTS connected to a permanent/hard wired power supply, which is buried to the tanks?

  • Is the irrigation line buried?

  • No garden hoses and fittings being used for irrigation?

  • Are standard irrigation warning signs present (green background with black or white writing)?

  • Is there sufficient irrigation area?

  • Is effluent being evenly distributed?

  • sprinklers are not being used directly to irrigate fruit trees or vegetables?

  • Is the effluent disposal area greater than 15 m to dwellings?

  • Is the effluent disposal area greater than 6 m up/3m down to driveways & property boundaries?

  • Is the effluent disposal area greater than 3 m to paths and walkways?

  • Is the effluent disposal area greater than 6 m to swimming pools?

  • Is the surface drip or trickle irrigation area greater than 6 m up gradient/ 3 m down gradient to pools, property boundaries, driveways & buildings?

  • Is the lid, manhole and inspection caps undamaged and in place?

  • Is the tank undamaged?

  • Is the tank accessible?

  • Sludge levels acceptable? Does not need a clean out.

  • Is trench performing ok?

  • Is greywater being disposed of satisfactorily?

  • If there is a grease trap, is it satisfactory?

  • Is the absorption system greater than 12 m if up gradient or 6m if down gradient to the property boundary?

  • Is the effluent disposal area greater than 6 m up/ 3 m down to pools, driveways and buildings?

  • Is the absorption area adequately isolated from livestock?

  • Is there a pump-out contract?

  • Are there maintenance records kept onsite?

  • Does the operator have pump-out receipts?

  • Tank is not surcharging or overflowing?

  • Are the lid, manhole and inspection caps undamaged and in place?

  • Is the tank undamaged?

  • is there a high level alarm?

  • If the pipe to mains is visible, is it cream coloured or have a cream stripe?

  • Is greywater being disposed of satisfactorily?

  • Is there a draw line with a cam lock?

  • If there is a grease trap, is it satisfactory?

  • Is the mound dry and appear to be operating ok?

  • Are the diverter and monitoring bore accessible?

  • Is stormwater diverted away from the mound?

  • Is the lid, manhole and inspection caps undamaged and in place?

  • Is the tank undamaged?

  • Is the tank accessible?

  • Sludge levels acceptable? Does not need a clean out.

  • Is greywater being disposed of satisfactorily?

  • If there is a grease trap, is it satisfactory?

  • Is the absorption system greater than 6m if up gradient/3m if down gradient of swimming pools, driveways and buildings?

  • Is the absorption system greater than 12 m if up gradient/6m if down gradient to the property boundary?

  • Is the absorption area adequately isolated from livestock?

  • Is there an external door, shute to collect the humus?

  • Does the fan operate continuously?

  • Is the compost humus used in an environmentally safe manner?

  • Does the system appear to not require attention?

  • Is greywater being disposed of satisfactorily?

  • Is the grease trap working efficiently?

  • Is the lid, manhole and inspection caps undamaged and in place?

  • Is the tank undamaged?

  • Is the tank accessible?

  • Sludge levels acceptable? Does not need a clean out.

  • Have service reports been sent to Council?

  • Does the system have maintenance by a service contractor?

  • Is greywater being disposed of satisfactorily?

  • Is the absorption system greater than 6m if up gradient/3m if down gradient of swimming pools, driveways and buildings?

  • Is the absorption system greater than 12 m if up gradient/6m if down gradient to the property boundary?

  • Is the absorption area adequately isolated from livestock?

Buffer distances

  • Is the effluent disposal area greater than 100 m to permanent surface waters?

  • Is the effluent disposal area greater than 250 m to domestic groundwater?

  • Is the effluent disposal area greater than 40 m to other waters (eg intermittent waterways, dams)?

Soil

  • What basic soil type is present (if known)?

Site Specific Issues

  • Does the site have any site specific issues? eg. Surface rock, light access/evaporation potential, steep slope >15%, heavy clays, small lot with limited on site capacity, other (specify)

Performance

  • Does the system comply with the performance standards?

  • Does the system prevent the spread of disease by micro-organisms?

  • Does the system prevent the spread of foul odours?

  • Does the system prevent the contamination of water?

  • Does the system prevent the degradation of soil and vegetation?

  • Does the system discourage insects and vermin?

  • Does the system minimise any adverse impacts on the amenity of the premises and surrounding lands?

  • Does the systems provide for the re-use of resources (including nutrients, organic matter and water?

Risk Assessment

  • Hydraulic Loading

  • Vegetation Cover

  • Soil type

  • Distance to watercourse

  • Distance to drains

  • Distance to neighbours

  • Surface effluent / waterlogging

  • Migration of "wet areas" off site

  • Presence of odours

  • Servicing / maintenance

  • Occupiers knowledge of system

Overall Risk Ranking

Comments

  • undefined

  • Site Plan - All On-site Effluent System Components Identified

  • Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.