Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
Date & Time:
-
Application No:
-
Address:
-
LOT No: DP No:
-
The work inspected:
-
Issue Plumbing Final Certificate:
-
Council Officer:
-
"Yes" denotes compliance
"No" denotes non-conformance
"N/A" denotes not applicable -
SITE CONTROLS - General
-
SC01 - Builders sign erected
-
SC02 - PCA sign erected
-
SC03 - Toilet on site
-
SC04 - Sedimentation controls in place &appropreate
-
SC05 - Single site access managed
-
SITE CONTROLS - Earthworks
-
SC05 - Unprotected cut battered correctly (<2m H:L)
-
SC06 - Unprotected fill battered correctly (<2m H:L)
-
SC07 - Excavation >3m from neighbors buildings
-
SC08 - Excavations DO NOT effect adjacent structures
-
CONSENT CONDITIONS & PREVIOUS INFNECTIONS
-
SC09 - DA conditions complied with
-
SC10 - Previous inspections instructions complied with
-
PLUMBING FINALS - Sewer
-
PF01 - Boundary riser IO above ground, accessible & concreted
-
PF02 - No surface water to ORG & 150 below lowest floor waste
-
PF03 - Wet Areas floors graded to suitable floor waste
-
PF04 - Vent pipes have cowl & deck tight fitted
-
PF05 - All existing manholes exposed at surface
-
PLUMBING FINALS - Stormwater
-
PF06 - All guttering & downpipes provided & secure
-
PF07 - Grates provided at surface water inlets
-
PF07 - Drains at bottom batter/slopes directed to storm water
-
PF08 - Drained to road/approved rubble pit
-
PF09 - Kerb repaired at approved storm water junction point
-
PF10 - Tank overflow to storm water
-
WATER SUPPLY
-
PF11 - Hot water less than 50 degrees
-
PF12 - Hot water system inlet fitted with ball valve isolation
-
PF13 - Copper hot water overflow discharge to ground level safely
-
PF14 - All pipe penetrations sealed
-
PF15 - Water meter must be connected using copper pipe
-
PF16 - Vacuum breakers fitted to all external taps
-
PF17 - All stop valves exposed at surface
-
PF18 - All fire hydrants exposed at surface
-
PF19
-
PF20
-
PLUMBING FINALS - Rain Water Tanks
-
PF21 - Mains top up supply has 100mm air gap to tank
-
PF22 - Above ground - Dual check valve installed at meter
-
PF23 - Below ground - Testable double check valve at meter
-
PF24
-
PF25
-
OTHER
-
PF26 - Gas bottles restrained and stable
-
PF27 - Gas bottles have compliance plate
-
PF28
-
PF29
-
PF30
-
OTHER INSTRUCTIONS & NOTES