Title Page
-
PMV Report Number:
-
Client / Site
-
Conducted on
-
Prepared by
-
Personnel
Equipment Information:
-
Machine Model Number:
-
Serial Number:
-
Water Filter System installed ?
-
Condition Photographs - External & Location
Preparation:
-
Empty Storage bin
-
Disconnect unit from the electrical supply
-
Disconnect water supply
-
Remove Ice Dispense Spout & 'sink' tray and clean as required before soaking in a sanitising solution until required later in the process
-
Remove top panel
-
Remove Left & Right panels as required to gain access to the water system. Remove Front panel for greater access if required
-
Drain water system, reconnect hose when drained
-
Inspect Internal water system hoses, clean or replace as required
-
Condition Photographs - Internal
Using the appropriate 'PPE' (Gloves, Specs etc):
-
Prepare a 'De-scaling' solution at a ratio of 10%
-
Fill the units water system with the solution
-
Let the system now 'steep' for approx 10 minutes
-
Run the machine for approx 5 minutes to agitate the solution inside the freezer assembly
-
Drain 'solution' from the water system
-
Refill and drain the water system 3 further times with fresh water
-
Prepare a 'sanitising' solution at a ratio of 10%
-
Fill the units water system with the solution
-
Let the system now soak for approx 10 minutes
-
Run the machine for approx 5 minutes to agitate the solution inside the freezer assembly
-
Drain the 'solution' from the water system
-
Refill & drain the water system a 3 further times with fresh water
NOTE - DO NOT MIX THE TWO SOLUTIONS !!!
-
Remove the 'Vane' motor assembly and storage bin cover
-
Clean the underside of the storage bin cover, clean/inspect the ice level sensor
-
Remove the vane & the base conical cover (remember the save the washer)
-
Clean the inside of the storage bin with a sanitiser solution. Clean the drain off point in the base
-
Reassemble the vane drive assembly and storage bin area, remount the vane motor assembly
-
Replace panels to unit and turn both electric & water supply on
-
Whilst unit is on 'start-up' mode, clean around the dispense area, especially the 'polo' ring area.
-
Pour warm solution into the tray area. Use long brush to clear drain off point
-
Check unit drain Hose, replace as required
-
Clean/wipe all external panels
-
Refit 'sink' & 'spout' to unit
-
Change water filter cartridge
-
Discard the units first 15 minutes of ice produced as a safety precaution following the PM
PMV Summary
-
Machine left in operation ?
-
Site Contact:
-
Select date