Title Page
-
Incorporates Prestart checklist, slicer Checksheets, Permitted Items, Control of Physical Contamination, Metal Detector Fail Safe Challenge Test.
-
Canberra
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
Date and Time of Audit
-
Production Day ? Enter the production day this audit is applicable to.
-
Carried Out By:
-
Carried Out By:(if second person involved.
-
Carried Out By:(if third person involved.
Slicer One
Metal Detector Fail Safe Challenge Test
-
Reject Confirmation<br>Insert test piece into product and pass down line, remove sample before reject mechanism and confirm that line stops.
-
Air Pressure<br>Run metal detector and turn off air isolation valve to confirm line stops.
-
Search Head Failure<br>Turn off metal detector belt and sit metal object (test weight) under head unit. After approx 15 secs the message "self check Magnitude Error" comes up on screen. After about 2 secs this message is replaced with "Balance Fault" which stays on screen until the object is removed and the belt is turned back on.
-
Back Up sensor<br>Run metal detector and cover sensor prior to M/D head for 5 secs to confirm line stops.
-
Photo Electric cell pre search head.<br>Insert test piece into leading edge of product and pass down line to and confirm that the product has been rejected into the reject bin.
-
Photo Electric cell pre search head<br>Insert test piece into trailing edge of product and pass down line to and confirm that the product is rejected into reject bin.
-
Metal Detector Verified by
-
Record any actions taken or needed.
Slicer Two
Metal Detector Fail Safe Challenge Test
-
Reject Confirmation<br>Insert test piece into product and pass down line, remove sample before reject mechanism and confirm that line stops.
-
Air Pressure<br>Run metal detector and turn off air isolation valve to confirm line stops.
-
Search Head Failure<br>Turn off metal detector belt and sit metal object (test weight) under head unit. After approx 15 secs the message "self check Magnitude Error" comes up on screen. After about 2 secs this message is replaced with "Balance Fault" which stays on screen until the object is removed and the belt is turned back on.
-
Back Up sensor<br>Run metal detector and cover sensor prior to M/D head for 5 secs to confirm line stops.
-
Photo Electric cell pre search head.<br>Insert test piece into leading edge of product and pass down line to and confirm that the product has been rejected into the reject bin.
-
Photo Electric cell pre search head<br>Insert test piece into trailing edge of product and pass down line to and confirm that the product is rejected into reject bin.
-
Metal Detector Verified by
Slicer Three
Metal Detector Fail Safe Challenge Test
-
Reject Confirmation<br>Insert test piece into product and pass down line, remove sample before reject mechanism and confirm that line stops.
-
Air Pressure<br>Run metal detector and turn off air isolation valve to confirm line stops.
-
Search Head Failure<br>Turn off metal detector belt and sit metal object (test weight) under head unit. After approx 15 secs the message "self check Magnitude Error" comes up on screen. After about 2 secs this message is replaced with "Balance Fault" which stays on screen until the object is removed and the belt is turned back on.
-
Back Up sensor<br>Run metal detector and cover sensor prior to M/D head for 5 secs to confirm line stops.
-
Photo Electric cell pre search head.<br>Insert test piece into leading edge of product and pass down line to and confirm that the product has been rejected into the reject bin.
-
Photo Electric cell pre search head<br>Insert test piece into trailing edge of product and pass down line to and confirm that the product is rejected into reject bin.
-
Metal Detector Verified by
-
Record any actions taken or needed.
-
Supervisor Signoff