Framing Site Inspection
Compliance Documents
-
Have you received the QA document from the Carpentry contractor?
-
Has the Building Certifier completed and passed the frame inspection?
-
Has the Certifier/Structural Engineer sighted and signed off the Structural Steel?
-
Are the frame and truss plans onsite for this inspection?
Timber Framing
-
Has the floor plan layout been checked against the working drawings?
-
Timber framing - Is all timber used the correct treatment and grading?
-
Wall frames - Are wall frames set out square?
-
Wall frames - Are bottom plates straight?
-
Wall frames - Are top plates straight?
-
Wall frames - Are wall frames installed plumb?
-
Wall frames - Have studs been checked for straight?
-
Wall frames - Are top plate connectors installed?
-
Wall frames - Bottom plate fixings installed as per structural engineering plans?
-
Wall frames - Are lintel sizes/fixings/stud supports and straps as as per structural engineering plans?
-
Wall frames - Are all point load stud locations/fixings correct and line up with the load it is supporting?
-
Wall frames - Are all fixings/connections correct in locations of timber beams to posts?
-
Wall frames - DPC installed under bottom plate?
-
Mid floor - Are wind beams installed as per working drawings, correct size and fixings?
-
Mid floor - Do the joist sizes and spans match the structural engineering drawings?
-
Mid floor - Are all bearers and structural joists the correct size, grade and span?
-
Mid floor - Is all mid floor hardware (joist hangers etc) installed as per working drawings?
-
Mid floor - Are the balcony joists installed with correct fall and step downs to comply with the NCC?
-
Mid floor - Has the flooring sheets been glued and fixed to the joists in the correct manner to prevent squeaks/creaks?
-
Roof framing - Is the truss spacing correct as per truss plan?
-
Roof framing - Is all truss hardware installed as per truss plan?
-
Roof framing - Are rafters the correct size and spacing?
-
Roof framing - Is the roof plane bracing installed to the roof where required, is it installed correctly?
Tie Down and Bracing
-
Tie Down - Are tie down rods installed as per structural design?
-
Tie Down - Are tie down rods all tightened up with no play?
-
Bracing - Is all sheet bracing locations installed as per structural design?
-
Bracing - Is sheet bracing nailed off with correct fixings and centres?
Structural Steel
-
Is all structural steel installed in the correct location?
-
Is all structural steel installed the correct finish for the location/exposure?
-
Is all structural steel the correct size/profile?
-
Are all structural steel connections bolted correctly and tight?
Passive Fire Framing
-
Has all required solid blocking been installed to fire walls?
-
Are all sheet joints solid blocked on timber fire walls - if applicable?