Information
-
Audit Title
-
Client / Site
-
Location
-
Prepared by
-
Contact phone number
-
Conducted on
-
Other staff
-
Development Application Number
-
Complying Development Number
-
Construction Certificate Number
Inspection items
-
Appropriate timber has been selected and utilised
-
Notes
-
Timber members are not defective
-
Notes
-
Spans are correct based on timber structural rating and sizes
-
Notes
-
Roof of layout are as per the development consent
-
Notes
-
Timber size is appropriate and grading is appropriate for the construction
-
Notes
-
All roof bracing is adequate and fixed appropriately to the top plates
-
Notes
-
Collar ties are installed and bolted with minimum M10 bolts
-
Notes
-
M16 bolts fixing rafter to ceiling joist for struts greater than 60 degrees
-
Notes
-
4 nails per end of a multigrip or triple grip
-
Notes
-
4 nails per end of a multigrip or triple grip and 2 nails of the grip to the top end of the top plate.
-
Notes
-
All timber is appropriately fixed to each other timber member or steel member
-
Notes
-
Under-perlins, struts and blocking have been installed correctly over a hanging beam or on to appropriately constructed studs with top plate
-
Notes
-
Penetrations, cuttings or notches do not exceed engineered timber product specifications or AS 1684 Timber Framing Code
-
Notes
-
All fire resistant material is installed appropriately in fire rated elements
-
Notes
-
Non-combustible materials have been installed as required
-
Notes
-
Unlike metals within the frame are spaced or adequately protected from galvanic corrosion
-
Notes
-
Correct cladding has been installed on the exterior of the structure
-
Notes
-
Hoop iron straps have been installed in single leaf masonry garage and double brick constructed dwellings
-
Notes
-
Truss system installed as per manufacturers specifications
-
Notes
-
Rafters have been adequately fixed to the top plates
-
Notes
-
Flashing is correctly installed
-
Notes
-
Insulation has been installed in accordance with BASIX
-
Notes
-
Development as per the Development Consent
-
Noted unauthorised development
-
Site notes
-
Photograph
Required information
-
Required information to be submitted to Council
- Engineers certificate certifying the timber frame outside the scope of AS 1684
- timber receipt denoting timber grade
- Engineers certificate for masonry outside the scope of AS 3700
- Installation certificate of all fire rated construction elements within roof space
- Engineers certificate for the steel component of the frame
- Truss details from manufacturer
- identification survey indicating overall heights of the structure
Inspection result
-
Result of the inspection
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory - reinspection required after rectification works carried out
- Unsatisfactory - works not complete
- Stop all works - contact councils duty planner on 9735 1222, regarding unauthorised works
-
Should you have any enquiries regarding this inspection report please contact Auburn City Council on 9735 1222 or via email council@auburn.nsw.gov.au or in person at the customer service centre located at 1Susan Street, Auburn.