Information

  • Document No.

  • Field Supervisor

  • OH Unit #

  • Operator # 1

  • Operator # 2

  • Other

  • Customer

  • LSD

  • Services

  • Other Services Run

  • Conducted on

  • Auditor

  • Location

Pre-Departure, Job Planning and Arrival

  • Were all down hole tools checked before leaving the shop?

  • Comments

  • Were the surface computer, depth, weight and satellite systems checked before leaving the shop?

  • Comments

  • Did the Logger and Pickup arrive 30 minutes early?

  • Comments

  • Was Dispatch notified with ETA to rig up?

  • Comments

  • Were the job job requirements discussed with the well site Rep?

  • Comments

  • Were all potential Zones of Interest obtained from well site Rep?

  • Comments

  • Were any difficult hole conditions identified/discussed with the client?

  • Comments

Pre-Job Well Site Preparation

  • Was the FLRA form completed with all TES personnel prior to commencing operations?

  • Add media

  • Comments

  • Was the surface equipment checked before rig up?

  • Comments

  • Was the satellite or phone connectivity checked before rig up?

  • Comments

  • Was the cable continuity/insulation checked before rig up?

  • Comments

  • Were all down hole tools checked on the catwalk before rig up?

  • Comments

  • Were the tool serial numbers visually confirmed and the calibrations verified by the TES Supervisor?

  • Comments

  • Are all tool calibrations current?

  • Add media

  • Comments

  • Were all pre-verifications performed before rig up?

  • Add media

  • Comments

  • Were all pre-verifications within tolerance?

  • Add media

  • Comments

  • Was all appropriate running gear (centralizers, stand-offs, etc.) utilized?

  • Add media

  • Comments

  • Was an offset log downloaded from the data portal before rig up?

  • Was an offset log obtained at the well site?

  • Comments

Rig Up

  • Was a pre rig up safety meeting conducted with the rig crew?

  • Add media

  • Comments

  • Was the rig up conducted according to TES SOP's?

  • Add media

  • Comments

  • Was a survey meter used while sourcing the tools?

  • Add media

  • Comments

  • Was the Radioactive Materials warning sign and all PPE utilized during Rig up?

  • Add media

  • Comments

  • Were the tools "zeroed" at the proper point (KB, Rig floor, etc.)?

  • Add media

  • Comments

Running in the Hole

  • Was a casing check performed according to TES SOP's?

  • Add media

  • Comments

  • Was Surface Casing measured within 0.5m of SC Driller depth?

  • Were the tools re-zeroed?

  • Comments

  • Were the callipers adjusted in casing to correct pipe ID?

  • Comments

  • Was a down log recorded from the casing shoe to TD?

  • Comments

  • Were appropriate winch speeds observed while running in the hole?

  • Add media

  • Comments

  • Were magnetic marks within tolerance (< 0.1m) on decent?

  • Add media

  • Comments

  • Is TD Logger +/- 1m of TD Driller?

  • What action was taken?

Repeat Section

  • Was the KERR Panel tension shut down set to minimize the risk of pull off?

  • Add media

  • Comments

  • Was a full 60m repeat log presented on all curves?

  • Add media

  • Comments

  • Was well created on the data portal?

  • Comments

  • Was well licence verified with an on-line source?

  • Comments

  • Was Dispatch notified at TD and given an estimated time of completion?

  • Comments

  • Was the client notified of TD if they requested to be?

  • Comments

Main Log

  • Are all curves on depth (+/- 0.1m) between repeat and main pass?

  • Add media

  • Comments

  • Do the Repeat and Main pass curves repeat within defined tolerances?

  • Add media

  • Comments

  • Do all curves match the offset logs?

  • Comments

  • Were any anomalies repeated and recorded in Log Comments?

  • Add media

  • Comments

  • Were quality data measurements observed in all zones of interest?

  • Comments

  • Is hole rugosity affecting log response?

  • What action was taken?

  • Were the "Quick Beams" checked for spelling mistakes and quality before posting to Data Portal?

  • Comments

  • Were the "Quick Beams" posted to the Data Portal in a timely manner?

  • Comments

  • Was the Calgary contact notified that the "Quick Beams" were posted?

  • Comments

  • Were any problems discussed with the Geo?

  • Comments

Logging Out

  • Were appropriate logging speeds observed during ascent?

  • Comments

  • Was the KERR Panel tension shut down adjusted during ascent to minimize risk of pull off?

  • Comments

  • Were the magnetic marks within tolerance (< 0.1m) on ascent?

  • Comments

  • Does the Surface Casing depth on Main log match casing check?

  • What action was taken?

  • Were the tools re-zeroed at surface to confirm depth?

  • What action was taken?

Rig Down

  • Was the "Squealer Valve" set 1-2 meters before reaching the rig floor?

  • Comments

  • Did the TES Supervisor receive permission to rig out equipment?

  • Comments

  • Were all SOP's followed during rig down?

  • Add media

  • Comments

  • Were all radiation safety procedures followed during rig down?

  • Add media

  • Comments

  • Were all tools cleaned properly on rig down?

  • Add media

  • Comments

  • Were tool post verifications completed?

  • Comments

  • Were tool post verifications within tolerances?

  • Comments

  • Was all TES equipment cleared from the rig floor, catwalk, etc.?

  • Add media

  • Comments

  • Was all TES equipment cleaned and checked prior to being loaded?

  • Add media

  • Comments

  • Was the cable head and line checked for leakage after the job?

  • Comments

Data Transmission

  • Were all of the services requested by the client completed successfully?

  • Comments

  • Were logs checked for quality and spelling?

  • Comments

  • Were all problems and log anomalies recorded in the log header?

  • Comments

  • Was the data transmitted according to the clients instructions?

  • Comments

  • Was the data package uploaded to PACS?

  • Comments

  • Was the client notified when the data was ready for viewing?

  • Comments

Job Completion at the Well Site

  • Was log data backed up?

  • Comments

  • Was job information entered into SharePoint?

  • Comments

  • Did the Client sign the Work Order?

  • Comments

  • Was an E-Ticket completed and transmitted before departing location?

  • Comments

  • Did the client receive the the required logs, LAS files, coy of E-Ticket?

  • Comments

  • Were all necessary maintenance requests entered into MC?

  • Comments

Post Job Departure

  • Did the TES Supervisor contact Dispatch prior to departing?

  • Comments

  • Were all problems (LTI, damaged tools, etc.) reported to Dispatch?

  • Comments

  • Was management and sales notified if a problem occurred that affected the quality of our service or product?

  • Comments

Stuck Tools/Fishing

  • Were all stuck tool procedures followed (eg. closing callipers)?

  • Comments

  • Was TES management, sales and the client notified of stuck tools?

  • Comments

  • Did Field Supervisor call in before pulling more than 50%?

  • Comments

  • Was a record kept of the tension pulled during attempts to free the tools?

  • Comments

  • Did the client receive an accurate diagram of the stuck tools?

  • Comments

  • Prior to fishing operations, was a safety meeting conducted?

  • Comments

  • Did the TES Field Supervisor prepare a detailed report and submit it to the OH Operations Manager and salesman?

  • Comments

Summary

  • Supervisor job performance met minimum standards.

  • Comments

  • Operator job performance met minimum standards.

  • Comments

  • Overall job quality met minimum standards.

  • Comments

  • Additional Comments

  • Auditor Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.