Install Checklist
-
Install Checklist
1. Document References - Project, Technical, Quality, OHS&E documents are available via Jason Vidulich
-
Latest versions of documents checked
2. OHS&E Requirements - Staff and contractors must abide by the relevant OH&S and Environmental requirements related to the construction works. OHS accrediation/competancy shall be adhered to as per required project, local council & state legislation/regulations
-
All OH&S and Environmental requirements completed / adhered to
-
Risk management completed for each site visit. ( JSA / SWMS )
-
Environmental practices implemented during the execution of works
-
Site induction log completed
-
Emergency plan completed for site
2. OHS&E Requirements
-
All OH&S and Environmental requirements completed / adhered to
-
Risk management completed for each site visit. ( JSA / SWMS )
-
Environmental practices implemented during the execution of works
-
Site induction log completed
-
Emergency plan completed for site
3. Hazard Notification - "Site entry notification must be submitted to the Telstra GOC. The GOC can be contacted via SMS on 0427 767 462. A type āCā hazard must be booked with the Telstra GOC for any 3G/CMUX/2G/1G extension work. The Telstra GOC can be contacted on 1300 652 235."
-
GOC notified of site entry at each visit (Phone : 1300 652 235)
-
GOC Confirmation - No Alarm at Site before commencing
-
All appropriate hazards approved. WINs / MOPS A STAC
4. Legacy Cabinet Check & Clean - Cabinet checks and clean.
-
Photos taken of housing before Top Hat installation. ( side, rear, front view )
-
Cabinet tilt is less than 50mm
-
Housing / site free of vegetation. (300mm)
-
Top of the housing cleaned and all dirt removed prior to TopHat installation
5. Legacy Cabinet preparation work - Cabinet preparation work prior to the installation of the ISAM 7330 Top Hat.
-
Cabinet preparation work completed as per I&C documentation
-
Rivet nuts correctly bolted
-
Cable access holes completed correctly
-
Swarf Removed
6. Strong Frame Installation with photos - Steps followed for the installation of Strong Frame on top of the RIM housing.
-
Compression foam installed. (6mm not 3mm)
-
Shims installed and strong frame level. (3mm)
-
Strong frame secured with M10 bolts and steel washer
-
Strong frame bolts tightened to 12nm Torque setting
7. Top Hat Installation With Photos - Procedures involved in placing the Top Hat on to the RIM cabinet.
-
Top Hat placed on legacy cabinet using mechanical aid. Submit picture of mechanical lift in progress
-
Sikaflex bead neatly placed between TopHat and Legacy cabinet
-
All excess Sikaflex removed from TopHat and Legacy cabinet
-
Drain plug installed with sikaflex - clear of obstruction
8. AC Electrical Installation
-
STAC Contacted 15min before commencing Power Work (Phone 1300 363 869 option 3)
-
AC extension cable with female socket installed to AC supply side
-
AC cable correctly routed from Power Compartment into TopHat
-
AC mains connection ( socket and plug ) enclosed by protective shroud
-
230VAC warning labels fitted to AC cable
-
Earth connected and secured
9. Battery Installation
-
Battery Installation Checklist completed
-
Batteries links installed as per I&C document. (600mm Leads)
-
Batteries connections torqued to 5-7nm
-
Installed Battery tray secured with cable tie at RHS
-
Battery Temp Sensor isolated and fixed into correct position
-
STAC Contacted Alarms Cleared - Power Hazard Closed
10. Optic Fibre, Board and Cable Installation
-
Fibre optic cables correctly routed through MEC into TopHat
-
80mm gap between existing and new O/F conduit
-
Fibre optic slack stored under ISAM 7330
-
Board / SFP type and quantity as per ALU direction / Telstra brief
-
ISAM Power and Earth connection completed - protective cover installed
-
X and C pair cables correctly connected and secured at ISAM
-
X and C pair cable correctly installed through gland - slack managed
-
X and C pair cables installed into legacy housing as per I&C document
-
Existing RIM/CMUX Cabling undisturbed
11. Commissioning
-
ISAM power up proceedure completed per I&C document
-
Mains and Battery Load Tests completed per I&C document
-
All optical links tested and optical power levels recorded
-
ISAM configured and Integrated by CDO
-
1 Speed test completed
-
1 modem sync test completed per installed LT
12. Labelling
-
Subrack and Cabinet label affixed as per I&C document
-
Copper cable labels affixed as per I&C document
-
Fibre cables labels affixed as per I&C document
13. DBoRs
-
All DBoRs submitted as per requirements and to standards
14. Final Inspection & Site Completion
-
All cabling is tidy and secured
-
All debris removed from the Tophat Cabinet ( dirt, broken cable ties etc )
-
All debris removed from the immedate area ( packaging etc )
-
All doors correctly closed and locked
-
All site works completed, documention completed, Matrix updated
-
GOC Confirmation - No Alarm at Site before leaving
As Built Photos
-
As Built Photos
1. Legacy Cabinet - include 3 photos of Legacy Cabinet (without THC installed)
-
1.1 Front view
-
1.2 Side view
-
1.3 Rear view
2. OHS management - include 2 photos of site OHS management (including cabinet in view)
-
2.1 Traffic / pedestrian view
-
2.2 Crane / Hiab in use
3. Penetrations & Strong Frame - include photos of Cabinet with Strong Frame and Penetrations
-
3.5 Strong Frame fitted with 3mm shimes and foam
-
3.1 1G penetrations
-
3.2 2G penetrations
-
3.3 3G penetrations
-
3.4 CMUX penetration
4. Rim Cabinet / Tophat installed - include 3 photos showing Tophat installed on Legacy housing NB: Legacy housing to be shown in photo
-
4.1 Front view with door closed
-
4.2 Front view with door open
-
4.3 Rear view
5. RIM Cabinet / Tophat installed - include 3 photos showing Sikaflex used
-
5.1 External front view
-
5.2 External rear view
-
5.3 Internal view of Drain Plug
6. Battery Installation - include 2 photos showing batteries installed and connected
-
6.1 View of all 4 batteries installed showing Long link cables used between 1&2 and 3&4
-
6.2 Battery Temp sensor installed
7. Cable management - include 3 photos
-
7.1 optical fibre storage at ISAM
-
7.2 X and C pair cables at THC glands
-
7.3 Power and Earth cables at Tophat cabinet
8. NON Broadband cable integration in legacy housing
-
8.1 new cable connections to cards
-
8.2 New cable connections to legacy cables
9. AC power connection - include 2 photos showing AC connected at Legacy housing Power compartment
-
9.1 AC plugs with shroud OPEN
-
9.2 AC cabling and plugs insitu
10. THC Labelling
-
10.4 CA to G number
-
10.5 Node code (5 Alpha)
-
10.6 MEC label sticker to inside of MEC door (CMUX only)
-
10.7 Schematic to inside of CCF door (Rim only)
-
10.1 Fibre labelling at ISAM
-
10.2 X and C pair at ISAM
-
10.3 ISAM subrack label
11. Tree or Branch Removal
-
11.1 View before cut
-
11.2 View after cut
-
11.3 Removed from site
12. Site Re-Instatement - including 3 photos showing overall footpath with cabinet
-
12.1 Front view
-
12.2 Side view
-
12.3 Rear view
13. CABLE, TAIL 4F SMOF
-
13.1 Manhole / Pits secure (guards)
-
13.2 Gas Detector in manhole
-
13.3 Pre splice in FAP / OJ
-
13.4 Post splice in FAP / OJ
-
13.5 White tagged
-
13.6 Kelvindale plug up with denso putty.
14. Exchange patching labels - include photos showing patching / splicing
-
14.1 HDODF
-
14.2 OMF
-
14.3 SDH/ SFP
16. Recovery AM35 Removal
-
16.1 Left Vertical
-
16.2 Right Vertical
-
16.3 Labels removed from MEC Door
-
16.4 WDM & Conduit removed from MEC
17. CMUX B.B cards removal
-
17.1 Electrical cables unplugged from slot 2 & 3
-
17.2 Fibres recovered to spool
-
17.3 Banking plates in Panel 1
-
17.4 Banking plates in Panel 2
15. THC-PLUG M12 LIFTING BOLT HOLES
-
15.1 The 4 plugs in THC
Completion
-