  • Document No.

VNY NORTH Monthly Fire Extinguisher Inspection

  • Conducted on

  • Prepared by

  • Location- Verify you are conducting Monthly Fire Extinguisher Inspection for VNY NORTH by entering "VNY North" below.

FIRE EXTINGUISHER INSPECTION INSTRUCTIONS Each fire extinguisher (Facility and Vehicle) needs to be inspected and signed off each month. The inspections should at a minimum include: o A visual inspection of the overall condition of the extinguisher and bracket. o Is the pressure gauge in the green? o Is the safety pull pin secured and in place? o Look at the discharge hose to be sure it is not pinched or damaged; be sure the end is not clogged, etc. o Is the monthly inspection tag attached and signed each month? o Is the annual inspection label attached? Is the annual inspection past due? o For wall mounted extinguishers there must be a clear path to the fire extinguisher- be sure there is nothing blocking access to the fire extinguisher, is there a sign on the wall identifying the extinguisher location? Is there a red box painted on the floor to show nothing should be stored in this area? o Any spare fire extinguishers should be stored in such a way as they are protected from falling over, and still need to be inspected monthly. o Any used or Out of Service fire extinguishers must be LOTO until they can be properly disposed of, and stored in a location where they will NOT be accessible in case of an emergency.

  • FIRE EXTINGUISHER <br>INSPECTION INSTRUCTIONS CON'T<br><br>Answering "S" for Satisfactory means you agree that you have performed the above required monthly inspection and initialed the monthly inspection tag. <br>If you answer "C" for Comment, please add a brief description of what the issue is and remove the fire extinguisher from service. Create a follow up action item to be sure the issue addressed, and replace the fire extinguisher with a spare. <br>Click YES to confirm you understand how to perform the Monthly Fire Extinguisher Inspection.<br>

VNY NORTH Fuel Trucks

  • J-30-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-30-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-31-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-31-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-32-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-32-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-304-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-304-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-305-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-305-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-522-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-522-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-94-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-94-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-1242-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-1242-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-1243-Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • J-1243-Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • A-15 Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • A-15 Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • A-43 Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • A-43 Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • A- 20 -Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • A-20 Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • A- 202 Left,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • A- 202 -Right,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

VNY NORTH Terminal

  • Fire Ext. # 1, Line Shack Hallway,<br>Annual Due in February, <br>Hydrostatic Test Due Feb XXXX

  • Fire Ext. # 2 Interior Hallway,<br>Annual Due in February, <br>Hydrostatic Test Due Feb XXXX

  • Fire Ext. #3 Interior near Exit,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

  • Fire Ext. # 4 Orbic Hallway,<br>Annual Due in February,<br>Hydrostatic Test Due Feb XXXX

VNY NORTH Hangar

  • Hangar VIP/ North Beam 1, Fire Extinguisher #1, <br>Annual Due February, <br>Hydrostatic Test Due XXXX

  • Hangar VIP/ North Beam 2, Fire Extinguisher #2 , <br>Annual Due February, <br>Hydrostatic Test Due XXXX

  • Hangar VIP/ North Beam 3, Fire Extinguisher #3, <br>Annual Due February, <br>Hydrostatic Test Due XXXX

  • Hangar VIP/ South Beam 1, Fire Extinguisher #1,<br>Annual Due February, <br>Hydrostatic Test Due XXXX

  • Hangar VIP/ South Beam 2, Fire Extinguisher #2,<br>Annual Due February, <br>Hydrostatic Test Due XXXX

  • Hangar VIP/ South Beam 2, Fire Extinguisher #2,<br>Annual Due February, <br>Hydrostatic Test Due XXXX

VNY NORTH Fuel Farm

  • Fuel Farm 20 lb. BC, Fire Extinguisher #XX (Get Number), West Pole, <br>Annual Due in February, <br>Hydrostatic Due in XXXX

  • Fuel Farm 20 lb. BC, Fire Extinguisher #XX (Get Number), East Pole, <br>Annual Due in February, <br>Hydrostatic Due in XXXX

  • Fuel Farm 125 lb. BC, Fire Extinguisher #XX (Get Number), Wheeled Unit, <br>Annual Due in February, <br>Hydrostatic Due in XXXX

  • Fuel Farm 125 lb. BC, Fire Extinguisher #XX (Get Number), Wheeled Unit, <br>Annual Due in February, <br>Hydrostatic Due in XXXX

VNY NORTH Eye Wash Station Inpsections

  • INSPECTION ITEMS:<br>To perform the monthly inspection on the eye wash stations: <br>o Initiate water flow. <br>o Ensure the caps or covers come off by themselves when water begins to flow. <br>o Run water until clear and clean.<br>o Ensure caps or covers are clean and replaced when finished.<br>o Make sure sink is clean. <br>o Verify the path to the eyewash station is clear and not blocked. <br>o Is there a sign above the identifying the location of the eyewash station?<br>o Date and initial the inspection tag attached to the eye wash station. <br>For portable bottles, <br>o Be sure the bottle is in place, <br>o The seal has not been broken, <br>o The expiration date is current, <br>o The exterior of the bottle is wiped clean. <br>Click yes to confirm you understand how to perform the Eyewash Inspection items.<br>

  • ENTER EYEWASH LOCATION HERE

  • ENTER EYEWASH LOCATION HERE

  • ENTER EYEWASH LOCATION HERE

  • ENTER EYEWASH LOCATION HERE

  • ENTER EYEWASH LOCATION HERE

  • ENTER EYEWASH LOCATION HERE

  • ENTER EYEWASH LOCATION HERE

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.