29 Active Cabinet Internal LHS
-
29.001 Outer Door lock works smoothly and door closes without jamming
-
29.002 Door stays are in place and all work well
-
29.003 Alarm warning sticker on inner door
-
29.004 Check Door alarm works with Telecom Security 0800 103060 - 2 - 6
-
29.005 AC earth rod installed next to Power duct & protrudes about 200mm above Plinth
-
29.006 AC Earth wire warning label attached (green or red plastic tag on the wire)
-
29.007 Power cable glands secure on the top of the RCD outlet box (2 small, 1 large)
-
29.008 Power cable gland secure to the right of the RCD outlet box through to the MUX bin. (1 large)
-
29.009 Power cable glands secure to the meter box. (1 large, 1 small for earth cable)
-
29.01 Power cable is installed in orange power duct.
-
29.011 Site tidy, no task waste
30 Active Cabinet Equipment
-
30.001 Inner Door lock works smoothly and door closes without jamming
-
30.002 Cabinet door pocket will contain Eaton QA sign off documents
-
30.003 Cabinet Telecom Earth tested <10 Ohms (in cabinet door pocket or iTools)
-
30.004 All walls have noise reduction Insulation installed
-
30.005 Earth and wrist strap installed
-
30.006 Heat sensor mounted top rear of MUX bin area (Small blue HS covered unit)
-
30.007 Fibre cable entry to Cabinet secured with cable gland, managed to OFDF OK
-
30.008 OFDF in a CNSP approved enclosure, netmap label on OFDF lid
-
30.009 Laser Safety labels (1M Safety) at OFDF (inside and front panel)
-
30.01 Cable entry to OFDF secured with cable gland
-
30.011 Fibre managed within OFDF OK
-
30.012 Protective caps on all unterminated connectors
-
30.013 Connectors cleaned and verified with Inspection Probe
-
30.014 30mm bending radius unconditionally observed at all locations
-
30.015 Fibre pigtail labels fitted with OFDF number and position designation
-
30.016 Site tidy, no fibre or task waste, all optical (glass) ends safely contained (H&S)
31 Active Cabinet Internal RHS
-
31.002 Door stays are in place and all work well
-
31.003 Alarm warning sticker on inner face of door
-
31.004 Soft foam seal plate secured. Cable entry prevents vermin/insect entry.
-
31.005 Cabling run correctly
-
31.006 MDF; Correct Modules installed
-
31.007 MDF; Module Labelling correct
-
31.008 MDF; Data card for jumper running data (laminated or in a card holder attached to the inside of door)
-
31.009 MDF; Cabinet E-side Termination data card in door.
-
31.01 MDF; Jumper correct type (BL/WH)
-
31.011 MDF; Jumper run correctly (50mm slack & no excess)
-
31.012 DC Earth rod installed between 100mm ducts and not protrude above plinth level.
-
31.013 AC & DC earth rod are made of same material, prevents electrolytic corrosion.
-
31.014 AC to DC bonding earth wire between distribution enclosure earth bar to AC switchboard earth bar is a 6 mm2 insulated conductor.
-
31.015 DC earth bar tie to Equipment earth bar is 16 mm2 insulated conductor.
-
31.016 Bottom LHS Earth bar strapped to each MDF vertical and the base of the cabinet
-
31.017 All crimped earth connections solid and secure
-
31.018 Ducts end about 100mm below top of plinth, no damage, reamed, tidy install.
-
31.019 6 Base securing bolts have washers and are tight.
32 Active Cabinet Battery Enclosure
-
32.001 Outer Door lock works smoothly and door closes without jamming
-
32.002 High Temp sensor in place
-
32.003 Battery terminals are covered in Petroleum Jelly or Vaseline
-
32.004 All Battery terminals are fitted with terminal covers.
-
32.005 Battery retaining brackets are tight and hold batteries securely
-
32.006 All Batteries labelled with install date (Electronic Marking system, eg P Touch)
37 Passive Copper Cabinet
-
37.001 Outer Door lock works smoothly and door closes without jamming
-
37.002 Door stays are in place and all work well
-
37.003 Cabling run correctly
-
37.004 Distribution Frame: Correct Modules installed
-
37.005 Distribution Frame: Module Labelling correct
-
37.006 Distribution Frame: Data card (laminated or in a card holder attached to the inside of CCC door)
-
37.007 Distribution Frame: Cabinet Laminated E-side Termination data card in door.
-
37.008 MDF; Jumper correct type (BL/WH)
-
37.009 MDF; Jumper run correctly (50mm slack & no excess)
-
37.01 MDF: All dead jumpers removed
-
37.011 Module support bars, separators and cover in place
-
37.012 Earth continuity installed
-
37.013 Lightning protection installed (when specified) or reinstated after testing
-
37.014 All duct seals in place
-
37.015 Concrete around ducts in base of cabinet
-
37.016 Locks & hinges OK
-
37.017 Door seals in good condition
-
37.018 Excess vegetation removed