Title Page

  • Date inspection completed

  • Site Location
  • Prepared by

  • Department

  • Person being reported on

  • Confirm the inspection category

Pre-work H&S Documentation for external operations

  • Has the POWRA been completed and signed by all involved?

  • Have operatives signed the appropriate RAMS and aware of where they are located?

  • Ensure colleague(s) are coached as to the documents location and why they need to know the importance of understanding the contents of the said document's.

  • Are all permits in place for the works being completed i.e. to dig or confined space entry?

  • Provide advice and guidance as to why the specific permit needs to be completed prior to works commencing.

Streetworks/Permitting and Site Set Up

  • Confirm all PPE required for the activity is being worn or readily available for use?

  • Has the traffic management system been set up in accordance with New Roads Street Works Act? (TM Company for Traffic Lighting)

  • Site Personnel are in possession of an up to date Street Works tickets (supervisor - operative)?

  • Take picture of the SWQR card as evidence.

  • Are the working areas being well managed with good housekeeping being maintained?

  • Are the contractors Information boards displayed at each end of the working areas along with the permit number?

  • Are the correct size signs / barriers / cones for the speed of road and all plant and equipment placed within the barriers?

  • Are pedestrian walkways compliant with the NRSWA (minimum width requirements (1.5m) absolute minimum 1m).

  • Are suitable measures in place to ensure residents are able to access / egress their properties safely and without risk of damaging vehicles?

  • Is the working area suitably segregated to ensure operatives and public safety is provided?

  • Sandbags available and used effectively.

Plant & Equipment

  • Confirm all PPE required for the activity is being worn or readily available for use?

  • Are there items of plant or equipment being used?

  • Is the Plant and Equipment in good condition and suitable for the work?

  • Are personnel trained and competent to operate the plant / equipment and hold the relevant CPCS or NPORS qualifications?

  • Are daily plant checks being completed with weekly checks recorded on the PUWER register?

  • Does equipment require calibrating and if so is the calibration up to date?

Work at Height: MEWP's

  • Confirm all PPE required for the activity is being worn or readily available for use?

  • Does the operator have an up to date IPAF ticket?

  • Have operatives working at height received the relevant training for the type of work undertaken? (PIA/NRSWA/Industry Safety)

  • Is there available an up to date thorough examination certificate (6 monthly) for the MEWP?

  • Has the permit to operate the MEWP been completed?

  • Have the daily pre-use checks being completed?

  • Does the machine look to be in good serviceable condition?

  • Are Safety Harnesses being worn and in good condition ?

  • Evidence of appropriate LOLER inspection undertaken (6 Months)

  • Has a suitable pre-climb check been completed?

  • Has a rescue plan been produced and communicated to the appointed person?

  • For PIA Poles: Does the operative know the process for contacting Openreach Pole Test Helpdesk?

Work at Height: Ladders/Harness/Pre-Climb Check

  • Confirm all PPE required for the activity is being worn or readily available for use?

  • Can the operative demonstrate pre-use checks on the ladder to be used?

  • Have the ladders been correctly secured in accordance with Tetra installation practices?

  • Work at height being undertaken in accordance with Openreach and National Grid safety controls

  • Have operatives working at height received the relevant training for the type of work undertaken? (PIA/NRSWA/Industry Safety)

  • PIA Pre Climb Check Document

  • For PIA Poles: Does the operative know the process for contacting Openreach Pole Test Helpdesk?

  • Can the user demonstrate the requirements for carrying out a pre-climb check?

  • Are Safety Harnesses being worn and in good condition ?

  • Evidence of appropriate LOLER inspection undertaken (6 Months)

  • Emergency rescue plan in place and suitable equipment and training provided?

Underground Chambers: Footway/Carriageway Chambers

  • Confirm all PPE required for the activity is being worn or readily available for use?

  • Is there available a gas detector with an up to date calibration certificate?

  • Check that lifting equipment is available and fit for purpose (mechanical lifter/t-keys/key lifter no.5/roller bar)?

  • Has the chamber been suitably guarded to protect operatives and members of the public against falls from height?

  • Can the operative demonstrate how to break the chamber seal and check for the presence of gas?

  • Can the operative describe the gases a GDU would detect?

  • Can the operative describe the actions required if gas is identified within a chamber?

  • Can the operative describe/demonstrate how to break the surface of the water (if present) during initial gas testing?

  • Can the operative demonstrate how to ingress/egress from the chamber (i.e. using step irons/avoiding existing equipment)

  • Is all work equipment contained within the boundary of the barriers?

  • Has the correct removal of chamber lid been followed by using the roller bar and lid left in final position off the roller bar?

  • Are the team aware of the risk from leptospirosis and taking suitable hygiene and protective measures? (information on Leptospirosis is contained on the back of ID cards)

  • Are the team aware of the risk of discarded used syringes (sharps) and have the equipment to deal with them?

Works in flight

  • Confirm on the day works

  • Has all equipment been inspected before use? (Sectional rods/cobra rods/X-boards)

  • Are all subduct drums/fibre cables being dispensed correctly within an active worksite?

  • For fibre cabling/splicing: are operatives dealing with fibre sharps responsibly?

  • For PIA Chambers: Does the operative understand the A1024 process when discovering damaged/obstructed chambers can they describe/demonstrate implementation?

Works completion

  • Have the cables/joints/gel-wraps been secured correctly (both the installation cables and pre-installed cables)?

  • Have the cables/joints/gel-wraps been labelled correctly - in line with PIA licence requirements and Wildanet Build Specification

  • Is the chamber clear of rubbish? (Openreach & Wildanet chambers)

  • Has the chamber lid been left secured and flush?

  • Has the site been shut down and reopened for users?

Underground Chambers: Confined Spaces/Manholes

  • Confirm all PPE required for the activity is being worn or readily available for use?

  • Where the risk assessment denotes the chamber as being a confined space, has the confined space permit been completed?

  • Are operatives confined space trained? and is the required rescue equipment provided?

  • Have provisions been made for air recirculation (with a blower)?

  • Is the tripod and winch available and serviceable for use?

  • Have the users carried out pre-use harness checks?

  • Does the chamber need pumping out (removal of water)? Have these provisions been made?

  • Is there available a gas detector with an up to date calibration certificate?

  • Can the operative describe the gases a GDU would detect?

  • Can the operative describe the actions required if gas is identified within a chamber?

  • Can the operative describe/demonstrate how to break the surface of the water (if present) during initial gas testing?

  • Check that lifting equipment is available and fit for purpose (mechanical lifter/t-keys)?

  • Has the chamber been suitably guarded to protect operatives and members of the public against falls from height?

  • Can the operative demonstrate how to break the chamber seal and check for the presence of gas?

  • Can the operative demonstrate how to ingress/egress from the chamber (i.e. using step irons/manhole ladder/avoiding existing equipment)

  • Is all work equipment contained within the boundary of the barriers?

  • Has the correct removal of chamber lid been followed?

  • Are the team aware of the risk from leptospirosis and taking suitable hygiene and protective measures? (information on Leptospirosis is contained on the back of ID cards)

  • Are the team aware of the risk of discarded used syringes (sharps) and have the equipment to deal with them?

Works in flight

  • Confirm on the day works

  • Has all equipment been inspected before use? (Sectional rods/cobra rods/X-boards etc)

  • Are all subduct drums/fibre cables being dispensed correctly within an active worksite?

  • For fibre cabling/splicing: are operatives dealing with fibre sharps responsibly?

  • For PIA Chambers: Does the operative understand the A1024 process when discovering damaged/obstructed chambers can they describe/demonstrate implementation?

Works completion

  • Have the cables/joints/gel-wraps been secured correctly (both the installation cables and pre-installed cables)?

  • Have the cables/joints/gel-wraps been labelled correctly - in line with PIA licence requirements and Wildanet Build Specification

  • Is the chamber clear of rubbish? (Openreach & Wildanet chambers)

  • Has the chamber lid been left secured and flush?

  • Has the site been shut down and reopened for users?

Fleet Vehicle/Pool Car

  • Have the user reported a pre-user check on the vehicle via CheckedSafe today?

  • Does the vehicle have any outstanding defects or scheduled maintenance?

  • Is there any internal or external damage to the vehicle not reported?

  • Are the front and rear number plates visible and in good condition?

  • Is the interior and exterior of the vehicle clean?

  • Confirm vehicle type

  • Are chapter 8 reflective markers and amber beacons clean and serviceable

  • Is the ladder rack/storage system in good condition and working correctly?

  • Are tools/equipment/stores secured within the load compartment?

  • Is a first aid kit/fire extinguisher/eye wash bottle or station available?

  • Are seat belts in good condition with no damage and operating correctly?

  • Functional test headlights/sidelights/brake lights/hazards/indicators. Do all function as expected?

  • Are the wipers/washers and horn working correctly?

  • Is the operator able to demonstrate how to open the bonnet and check fluid levels (oil, water, coolant, brake fluid)?

  • Are all tyres in good condition with a minimum of 2mm tread depth present

  • Vehicle is unsafe for use and tyre/s must be replaced.

Office Environment

  • Has the user logged in today when they arrived at the building?

Desk Setup

  • Is the user's desk setup in a suitable manner? (monitor positioning/wrist support/keyboard and mouse accessibility/cables stowed and tidied/no trip or spillage hazards)

  • Is the user taking regular rests for their eyes during PC usage? (20/20/20 guidance)

  • Is the chair provided supportive and adjusted for the individual?

First Aid/Welfare

  • Does the individual know the location of the nearest first aid kit?

  • Does the individual know who the nominated first aider on site is?

  • Does the individual know where the nearest welfare facilities are located (canteen, toilets, drying room etc.) ?

Fire/Emergency Situations

  • Does the individual know the nearest fire muster point to their location?

  • Does the individual know when the fire alarm checks are routinely carried out?

  • Does the individual know what actions to take in the event of a fire?

  • Does the individual know the location of the nearest fire alarm?

  • Is the individual aware of the nearest fire extinguisher?

Slips/Trips/Falls

  • Is the individual aware of actions to take on discovering a spillage/trip hazard?

  • Can the individual demonstrate the location of the nearest supply cupboard? (mop/bucket/wetfloor sign/dustpan & brush etc)

Sign Off

  • Feedback and summary

Sign Off

  • Operative

  • Auditor

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.