INTRODUCTION

  • Name of Airport?

  • What is the Airport ARFF Index?

  • What is the Airport Classification?

  • Does the proposed ARFF station provide adequate space for ARFF personnel, vehicle, equipment, and their related functions as prescribed by FAR 139.317 for certification?

  • Does the department provide EMS service?

  • Is a bay needed for over-head vehicle servicing?

ARFF APPARATUS BAYS (AC 150/5210-15)

  • Meets vehicle configuration (L/H/W) according AC 150/5210-15 Appendix A

  • Free personnel access from all interior / exterior access points.

  • Side by side parking versus tandem parking

  • Drive through bays

  • Observer's Comments:

ARFF APPARATUS BAYS STANDARD CLEARANCES (AC 150/5210-15)

  • 6 feet between vehicles walls and storage areas.

  • 8 feet between vehicles parked side by side.

  • 5 feet between vehicle parked end to end.

  • 5 feet between the vehicle and apparatus bay doors

  • 7 feet between the top of vehicle platform and ceiling.

  • 10 square feet of Personal Protection Equipment Storage.

  • Is 10% of space allocated for additional apparatus bay storage?

  • Observer's Comments:

ARFF APPARATUS BAYS ELECTRICAL DETAILS (AC 150/5210-15)

  • Are lighting levels provided per AC 150/5210-15, Chapter 3?

  • Are electrical outlets provided 18" - 24" above the floor and spaced at 8 feet intervals?

  • Are retractable electrical reels provided that service vehicle electrical systems?

  • Conduit should be provided to allow for future expansion

  • Observer's Comments:

ARFF APPARATUS BAYS INTERIOR ENVIRONMENT (AC 150/5210-15)

  • Is a vehicle exhaust extraction system provided and vented to the outside?

  • Are carbon monoxide detectors installed to sense CO in living quarters?

  • Are walls designed for easy cleaning and low maintenance?

  • Observer's Comments:

ARFF APPARATUS BAYS VEHICLE SUPPORT EQUIPMENT (AC 150/5210-15)

  • Is an over-head hoist provided?

  • Is the over-head hoist a minimum 1 ton rated device?

  • Has a vehicle water re-supply connection been provided (AC 150/5220-4)

  • Is a utility room provided with a deep slope sink, hot / cold water outlets, and mop wriner?

  • Is the utility room provided at least 64 - 100 square feet in size?

  • Is a compressed air supply capable of supplying a minimum of 120 psi available to maintain vehicle air supply system?

  • Is a foam agent recharging capability provided? Is it a overhead system or a transfer pumping system?

  • Observer's Comments:

ARFF APPARATUS BAY DOORS (AC 150/5210-15)

  • Are apparatus bay doors a minimum 16 X16 feet?

  • Is the maximum time to raise apparatus bay doors 16 seconds?

  • Are doors remotely operated from the alarm / watch room?

  • Is each door provided with a separate electrical operating control switch located adjacent to the door?

  • Are doors provided with a manual pull chain in the event of electrical system or switch failure?

  • Is each apparatus / bay door provided with a manual over-ride?

  • Are doors equipped with adjustable timers designed to close to prevent energy loss?

  • Are automatic door retractors provided on each door?

  • Are electrical "eye beams" installed to reverse door closing? Are they correctly mounted and do they function properly to preclude equipment or personnel injury?

  • Are doors equipped with windows? If windows are installed, are they tempered safety glass, and shatter proof?

  • Are apparatus bay doors insulated and provided with weather stripping?

  • Observer's Comments:

ARFF APPARATUS BAYS VEHICLE ROOM FLOOR (AC 150/5210-15)

  • Are floors designed to support current and future vehicle weight and footprints?

  • To prevent injury are adjacent room floors on the same level plane as the apparatus floor?

  • Are floor surfaces resilient to various liquids? Are they smooth surfaced and easy to clean?

  • Do floors have a minimum 1 inch (2.5 cm) to 10 feet (3M) slope to a center line transverse drain collection point?

  • Is the apparatus floor provided with a traverse drain heavy gauge cover, sediment / grease trap?

  • Observer's Comments:

ARFF APPARATUS BAY SLIDING POLES (NFPA 1500)

  • Meets safety requirements identified in NFPA 1500

  • Are poles located near walls and positioned away from obstructions?

  • Observer's Comments:

ARFF STATION APRON (AC 150/5210-15)

  • Does the apron / driveway have direct access to the aircraft movement area?

  • Does the apron area have exterior hose bibs with garden hose connections?

  • Are fire hydrants adjacent to the ARFF Station?

  • If wall hydrants are provided, are they corrected labeled?

  • Are pedestrian / vehicle traffic warning lights installed for location where traffic crosses the apron?

  • Observer's Comments:

ARFF STATION APRON STANDARDS (AC 150/5210-15)

  • Is the apron operating surface large enough to allow the longest vehicle access to any apparatus bay?

  • Is the apron at least 28 feet wide?

  • Is the apron length at least 1.5 times the longest vehicle lenght?

  • Are they tapered to not less that 28 feet for multi-vehicle stations?

  • Are they tapered to not less than 12 feet for single-vehicle stations?

  • Is the apron strength that same as the apparatus bay?

  • Gradient - Is the apron slope a minimum of 2 - 4 degrees and is it directed away from the apparatus bays?

  • Marking - Is the floor and apron striping provided? Is it at least 1.5 times the vehicle length for the apron?

  • Lighting - Is exterior lighting provided? Is it mounted to prevent view obstruction?

  • Apron Canopy - Is an apron canopy provided?

  • Are concrete bollards provided on each side of bay doors to prevent structural damage from backing vehicles?

  • Observer's Comments:

ARFF STATION WATCH / ALARM ROOM (AC 150/5210-15)

  • Is a watch / alarm provided for the receipt and dissemination of alarms, dispatch of equipment, and directing support resources?

  • General Design - Is the watch / alarm room provide for maximum surveillance of the airfield and apparatus bays? If deemed necessary, is the room elevated?

  • Is the room a minimum of 130 square feet? Does it have sufficient storage space and wall space for maps, reference material, and dispatch equipment?

  • Is the room equipped with a CCTV for security purpose?

  • Alternate emergency back-up power?

  • Accessibility to controls for electronic or electrical servicing / maintenance personnel?

  • Computer system with LAN access?

  • Radio equipment - ARFF and tunable radio capability?

  • Room dimmer switch and non-glare lighting?

  • Tinted glass?

  • A lavatory?

  • Backlit clock with 12 and 24 hour display?

  • Sound suppression to offset ARFF and aircraft sound levels?

  • Alarm - Are chimes / alert tones provided throughout the station and satellite stations?

  • Alarm - Is an audible alarm provided when auxiliary firefighters supplement emergency response personnel?

  • Alarm - Are all watch / alarm room controls easily accessible and with in reach of all operators?

  • Observer's Comments:

ARFF STATION MEDICAL DECON ROOM (AC 150/5210-15)

  • Is a room dedicated for medical clean-up and decontamination of ARFF personnel?

  • I the room equipped with a double sink, a shower, and drying area?

  • Is the space a minimum of 150 square feet?

  • Observer's Comments:

ARFF STATION GEAR WASHING / DRYING ROOM (AC 150/5210-15)

  • Is the room equipped with a commercial extractor washer and a heated drying rack?

  • Is the space a minimum of 200 square feet?

  • Observer's Comments:

ARFF STATION FIRST AID AND MEDICAL STORAGE (AC 150/5210-15)

  • Is a room dedicated for medical treatment or personnel seeking medical treatment?

  • Is the room lockable and equipped with a sink and cabinets for medical storage?

  • Is the space a minimum of 120 square feet?

  • Observer's Comments:

ARFF STATION COMPLIMENTARY AGENT STORAGE (AC 150/5210-15)

  • Is a storage room dedicated for the storage of Dry Chemical, Halon, Powder Fire Fighting Agents, and Nitrogen Cylinders?

  • Are doors of sufficient width to accommodate a forklift for their delivery of 4X4 pallets?

  • Is the space a minimum of 225 - 350 square feet?

  • Observer's Comments:

ARFF STATION SCBA AND FIRE EXTINGUISHER ROOM (AC 150/5210-15)

  • Is a room dedicated for the servicing and repair of SCBA and Fire Extinguishers?

  • Is the room provided with storage cabinets and a workbench to perform tasks and store materials and parts?

  • Is the space a minimum of 200 square feet?

  • Is an air filtration system available for re-servicing of SCBA?

  • Is an air compressor provided?

  • Is a cascade system used?

  • Are all components properly marked with labels / placards or signs that identify nomenclatures?

  • Are tags and warning labels affixed to equipment for safety operations?

  • Observer's Comments:

ARFF STATION HOSE DRYING FACILITIES (AC 150/5210-15)

  • Is the space a minimum of 150 square feet?

  • Is a drying rack required?

  • Is a mechanical drying machine required?

  • Are hose storage rack provided?

  • Observer's Comments:

ARFF STATION VEHICLE FUELING AREA (AC 150/5210-15)

  • Is an area adjacent to the apron provided for re-fueling?

  • Are fuel pumps adequately protected from physical damage?

  • Raised platform?

  • Bollards?

  • Are automatic / remote shut offs provided? Are distinct signs provided?

  • Do fuel storage tanks meets all standard requirements?

  • Observer's Comments:

ARFF STATION DAY ROOM (AC 150/5210-15)

  • Is a minimum of 20 square feet per person provided?

  • Is it furnished to provide a relaxing atmosphere?

  • Does it include furnishings, television, radio, tables, and other amenities for relaxtion?

  • Speakers for alarm notification announcements?

  • Observer's Comments:

ARFF STATION SLEEPING ROOMS (AC 150/5210-15)

  • Is the space a minimum of 140 square feet per firefighter?

  • Bedding / Mattress / Box spring / Framing / Headboard / Footboard

  • Nightstand and lamp?

  • Small desk and chair?

  • Lockable storage unit?

  • Speakers for alarm notification announcements?

  • Observer's Comments:

ARFF STATION LOCKER ROOMS (AC 150/5210-15)

  • Does the location provide for 15 square feet of space per firefighter, to include the space used by the locker itself?

  • Is locker space a minimum of 18 inches by 24 inches by 78 inches?

  • Is a locker provided for each individual firefighter?

  • Speakers for alarm notification announcements?

  • Observer's Comments:

ARFF STATION LAVATORIES (AC 150/5210-15)

  • Toilets, urinals, sinks, showers as appropriate based on local building codes?

  • Individual shower stalls - minimum of 9 square feet?

  • Clothing hooks, towels bars, soap dishes?

  • Ground Fault Interrupter (GFI) Outlets?

  • Ceiling and walls of water resistant materials?

  • Flooring that is slip resistant materials?

  • Vanity Mirrors of sufficient size for 3 personnel to use simultaneously?

  • Speakers for alarm notification announcements?

  • Observer's Comments:

ARFF STATION KITCHEN / DINING ROOM (AC 150/5210-15)

  • Is the space a minimum of 400 square feet?

  • Is the kitchen area of sufficient size to accommodate a commercial range, griddle, refrigerator / freezer (for each shift), microwave, food preparation area, storage and shelving for cooking utensils, a double sink with garbage disposal, commercial ice-maker, and commercial dishwasher?

  • Is an exit available that leads directly to the outside?

  • Do cooking appliances have a "manual shut-off" button to kill power or gas supply to the cooking devices when firefighters are dispatched?

  • Speakers for alarm notification announcements?

  • Observer's Comments:

ARFF STATION TRAINING ROOM (AC 150/5210-15)

  • Is the space a minimum of 48 square feet per firefighter?

  • Is secure storage space provided?

  • Are desk provided / or classroom seating provided?

  • Speakers for alarm notification announcements?

  • Observer's Comments:

ARFF STATION EMERGENCY GENERATOR ROOM (AC 150/5210-15)

  • Is a separate room provided for an emergency generator?

  • Is the generator of sufficient size to support all essential services?

  • Is the room equipped with an exterior access for maintenance and repair work?

  • Is the fuel supply sufficient to operate the generator under maximum load for a minimum 7 day period?

  • Is the room enclosed by fire rated walls and ceiling?

  • Speakers for alarm notification announcements?

  • Observer's Comments:

ARFF STATION PARKING AREA (AC 150/5210-15)

  • Is one space per on-duty firefighter provided?

  • Is access to parking controlled?

  • Is visitor parking provided?

  • Is Handicap parking provided?

  • Is access to parking designed to comply with ADA requirements?

MISCELLANEOUS OBSERVATION(S) & PHOTO(S)

  • Miscellaneous Observation(s)

  • Miscellaneous Photo(s)

SIGNATURE OF OBSERVER & COMMENTS

  • Observer"s Comments

  • Name & Signature of Observer

  • Date & Time of Observation

  • Date Reviewed By AIR - L thru AIR - LF

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.