Title Page

  • Site Code

  • Site Name

  • Completed By

  • Completed On

  • Build Company

Checksheet

  • Asbuilt Checklist (SITE_2039_Nokia-Spark_5G_Build Checklist_Connect8_DDMMYY)

  • Floor Layout (SITE_2039_Nokia-Spark_5G_FLR LAYOUT_Connect8_DDMMYY)

  • REDLINE MARKUP of Site and Land Plan (SITE_2039_Nokia-Spark_5G_RLMConstruction Drawing_Version X_Connect8_DDMMYY)

  • RF Plumbing Diagram (SITE_RFPD RLM_2039 Nokia-Spark 5G)

  • i-Auditor QA Report (SITE_QA Checksheet_2039 Nokia-Spark 5G)

  • i-Auditor Site Assessment Safety Critical Risks (SITE_Safety Site Assessment_2039 Nokia-Spark 5G)

  • GPS Alignment Result (SITE_2039_Nokia-Spark_5G_GPS ALIGNMENT_Version X_Connect8_DDMMYY)

  • RFS Checksheet (SITE_2039_Nokia-Spark_5G_RFS Checksheet_Version X_Connect8_DDMMYY)

  • RF Cable Antenna Sweeps (SITE_RF Sweeps_2039 Nokia-Spark 5G)

  • Hybrid Cable Test Sheet (SITE_2039_Nokia-Spark_5G_HYBRID_Version X_Connect8_DDMMYY)

  • Completed Access Template (SITE_2039_Nokia-Spark_5G_ACCESS TEMPLATE COMPLETED_Connect8_DDMMYY)

  • PS3 - Producer Statement Construction (PS3) - Rigging (SITE_2039_Nokia-Spark_5G_PS3 RIGGING_Connect8_DDMMYY)

  • Electrical Code Of Compliance (SITE_2039_Nokia-Spark_5G_CoC_Connect8_DDMMYY)

  • Emaint Form

Pictures

  • XXXX_S01 (General site overview of shelter and tower, plus surrounding buildings (taken from standing position showing ground and about 20m either side of antenna). Must be taken post-scaffolding removal.)

  • XXXX_S02 (Compound showing any co-located outdoor cabinets / shelters / towers)

  • XXXX_S03 (New Sites Only - Site Access - Main entrance door or first gate off road)

  • XXXX_S04 (New Sites Only - Site Access - Internal entry door(s) and stairway(s) or subsequent access track gates or track intersections)

  • XXXX_S05 (New Sites Only - Site Access - Building / Rooftop walkways)

  • XXXX_S06 (Site Access - other (e.g. "4WD only" or other site-specific signs))

  • XXXX_S08 (Signage - yellow PPE sign at entrance to site, or on shelter or cabinet door, showing site code)

  • XXXX_S09 (Signage - RF Hazard - tower; mast; streetlight pole; rooftop (wall or parapet))

  • XXXX_H01 (Outdoor cabinet(s) - wide shot of all cabinets with doors closed)

  • XXXX_H02 (Outdoor cabinet(s) – separate photos for each individual cabinet, with the door open showing installed units and associated cabling)

  • XXXX_H03 (Shelter / Room - Inside - LHS corner inside door, photo to include floor and ceiling)

  • XXXX_H04 (Shelter / Room - Inside - LHS far corner from door, photo to include floor and ceiling)

  • XXXX_H05 (Shelter / Room - Inisde - RHS far corner from door, photo to include floor and ceiling)

  • XXXX_H06 (Shelter / Room - Inisde - RHS corner inside door, photo to include floor and ceiling)

  • XXXX_H07 (Shelter / Room - Inside - non-standard (e.g. equipment room with a different shape))

  • XXXX_H08 (Cable entry from inside (floor or wall - some sites may have both))

  • XXXX_H09 (CHORUS ONLY - Cable entry from outside)

  • XXXX_H20 (CHORUS ONLY - Panoramic view of entire equipment room)

  • XXXX_T01_S_Y (Antenna - close up showing labelling)

  • XXXX_T02_S_Y (RRU/ RRH plus mount - close up (unit mounted individually) showing labelling is visible)

  • XXXX_T03_S_Y (RRU / RRH plus mount - close up (units mounted in a group) showing labelling is visible)

  • XXXX_T04_S_Y (Building & Tower / Antennas / RRU / RRH - wide shot of each sector)

  • XXXX_T09 (Tower - head)

  • XXXX_T10 (Tower - whole)

  • XXXX_T11 (Inside of tower base showing the cable ducts / earthing)

  • XXXX_T12_S_Y (Inside of tower base showing ducts)

  • XXXX_T13 (GPS Antenna (showing location e.g. exchange rooftop, tower, shelter))

  • XXXX_T14_S_Y (Sector coverage (ideally taken looking over the top of the antenna). Technology ID required only if there are multiple antennas on a sector)

  • XXXX_T15 (Existing tower foundations / anchor blocks)

  • XXXX_E01 (Indoor cabinet - door open (3900L, 37U))

  • XXXX_E08 (First DCDU on site)

  • XXXX_E08_aaa (Each additional DCDU on site)

  • XXXX_E09 (First MTP tray / fibre patch panel on site)

  • XXXX_E09_aaa (Each additional MTP tray / fibre patch panel on site)

  • XXXX_P01 (Indoor cabinet - whole cabinet view showing number of rectifiers and battery banks installed (note: do not remove grill just to take this photo))

  • XXXX_P04 (DC Circuit Breaker Panel (in both Eaton and 37U cabinets))

  • XXXX_P05 (DC Circuit breaker panel Legend Sheet in Eaton cabinet (label card must match circuit breakers))

  • XXXX_P08 (New Sites Only - AC power meter and Metering Installation Certificate (needed for as-builts only on new sites))

  • XXXX_P09_Before (Load current in Eaton rectifier cabinet before integration)

  • XXXX_P09_After (Load current in Eaton rectifier cabinet after integration)

  • XXXX_P10 (All cabinets - close up of batteries to show amp/hours rating. Take this photo through the front grill of indoor cabinets unless this has already been removed)

  • XXXX_P11 (New Sites Only - Earth resistivity label)

  • XXXX_P13 (CHORUS ONLY - Photo of AC distribution board feeding the mobile site.)

  • XXXX_P14 (CHORUS ONLY - Photo of AC breaker feeding the mobile site.)

  • XXXX_F01 (FirePro Unit installation - Utility Cabinet (where site in public land or road reserve))

  • XXXX_F02 (FirePro Unit installation - Tower (where site in public land or road reserve))

  • XXXX_F03 (Fire Stopping (Building Penetrations, Utility Cabinet, Feeder Ducts))

  • XXXX_L01 (Top Anchor)

  • XXXX_L02 (Bottom Tensioner)

  • XXXX_L03 (Tag)

  • XXXX_L04 (View looking up tower shaft with Latchway completed)

  • XXXX_C01_PrePour (Pre pour and after photo of any changes to the foundations)

  • XXXX_C02 (Before and after photo of any new steelwork or strengthening on the tower (hold down bolts, flanges, mounts, headframes, guy wires and hardware))

  • XXXX_C03 (Guy wire photo with ruler/caliper showing the actual size of the new guy wires)

  • XXXX_C04 (Tagged Anchor Points)

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.