Title Page
-
Site Code
-
Site Name
-
Completed By
-
Completed On
-
Build Company
Checksheet
-
Asbuilt Checklist (SITE_2039_Nokia-Spark_5G_Build Checklist_Connect8_DDMMYY)
-
Floor Layout (SITE_2039_Nokia-Spark_5G_FLR LAYOUT_Connect8_DDMMYY)
-
REDLINE MARKUP of Site and Land Plan (SITE_2039_Nokia-Spark_5G_RLMConstruction Drawing_Version X_Connect8_DDMMYY)
-
RF Plumbing Diagram (SITE_RFPD RLM_2039 Nokia-Spark 5G)
-
i-Auditor QA Report (SITE_QA Checksheet_2039 Nokia-Spark 5G)
-
i-Auditor Site Assessment Safety Critical Risks (SITE_Safety Site Assessment_2039 Nokia-Spark 5G)
-
GPS Alignment Result (SITE_2039_Nokia-Spark_5G_GPS ALIGNMENT_Version X_Connect8_DDMMYY)
-
RFS Checksheet (SITE_2039_Nokia-Spark_5G_RFS Checksheet_Version X_Connect8_DDMMYY)
-
RF Cable Antenna Sweeps (SITE_RF Sweeps_2039 Nokia-Spark 5G)
-
Hybrid Cable Test Sheet (SITE_2039_Nokia-Spark_5G_HYBRID_Version X_Connect8_DDMMYY)
-
Completed Access Template (SITE_2039_Nokia-Spark_5G_ACCESS TEMPLATE COMPLETED_Connect8_DDMMYY)
-
PS3 - Producer Statement Construction (PS3) - Rigging (SITE_2039_Nokia-Spark_5G_PS3 RIGGING_Connect8_DDMMYY)
-
Electrical Code Of Compliance (SITE_2039_Nokia-Spark_5G_CoC_Connect8_DDMMYY)
-
Emaint Form
Pictures
-
XXXX_S01 (General site overview of shelter and tower, plus surrounding buildings (taken from standing position showing ground and about 20m either side of antenna). Must be taken post-scaffolding removal.)
-
XXXX_S02 (Compound showing any co-located outdoor cabinets / shelters / towers)
-
XXXX_S03 (New Sites Only - Site Access - Main entrance door or first gate off road)
-
XXXX_S04 (New Sites Only - Site Access - Internal entry door(s) and stairway(s) or subsequent access track gates or track intersections)
-
XXXX_S05 (New Sites Only - Site Access - Building / Rooftop walkways)
-
XXXX_S06 (Site Access - other (e.g. "4WD only" or other site-specific signs))
-
XXXX_S08 (Signage - yellow PPE sign at entrance to site, or on shelter or cabinet door, showing site code)
-
XXXX_S09 (Signage - RF Hazard - tower; mast; streetlight pole; rooftop (wall or parapet))
-
XXXX_H01 (Outdoor cabinet(s) - wide shot of all cabinets with doors closed)
-
XXXX_H02 (Outdoor cabinet(s) – separate photos for each individual cabinet, with the door open showing installed units and associated cabling)
-
XXXX_H03 (Shelter / Room - Inside - LHS corner inside door, photo to include floor and ceiling)
-
XXXX_H04 (Shelter / Room - Inside - LHS far corner from door, photo to include floor and ceiling)
-
XXXX_H05 (Shelter / Room - Inisde - RHS far corner from door, photo to include floor and ceiling)
-
XXXX_H06 (Shelter / Room - Inisde - RHS corner inside door, photo to include floor and ceiling)
-
XXXX_H07 (Shelter / Room - Inside - non-standard (e.g. equipment room with a different shape))
-
XXXX_H08 (Cable entry from inside (floor or wall - some sites may have both))
-
XXXX_H09 (CHORUS ONLY - Cable entry from outside)
-
XXXX_H20 (CHORUS ONLY - Panoramic view of entire equipment room)
-
XXXX_T01_S_Y (Antenna - close up showing labelling)
-
XXXX_T02_S_Y (RRU/ RRH plus mount - close up (unit mounted individually) showing labelling is visible)
-
XXXX_T03_S_Y (RRU / RRH plus mount - close up (units mounted in a group) showing labelling is visible)
-
XXXX_T04_S_Y (Building & Tower / Antennas / RRU / RRH - wide shot of each sector)
-
XXXX_T09 (Tower - head)
-
XXXX_T10 (Tower - whole)
-
XXXX_T11 (Inside of tower base showing the cable ducts / earthing)
-
XXXX_T12_S_Y (Inside of tower base showing ducts)
-
XXXX_T13 (GPS Antenna (showing location e.g. exchange rooftop, tower, shelter))
-
XXXX_T14_S_Y (Sector coverage (ideally taken looking over the top of the antenna). Technology ID required only if there are multiple antennas on a sector)
-
XXXX_T15 (Existing tower foundations / anchor blocks)
-
XXXX_E01 (Indoor cabinet - door open (3900L, 37U))
-
XXXX_E08 (First DCDU on site)
-
XXXX_E08_aaa (Each additional DCDU on site)
-
XXXX_E09 (First MTP tray / fibre patch panel on site)
-
XXXX_E09_aaa (Each additional MTP tray / fibre patch panel on site)
-
XXXX_P01 (Indoor cabinet - whole cabinet view showing number of rectifiers and battery banks installed (note: do not remove grill just to take this photo))
-
XXXX_P04 (DC Circuit Breaker Panel (in both Eaton and 37U cabinets))
-
XXXX_P05 (DC Circuit breaker panel Legend Sheet in Eaton cabinet (label card must match circuit breakers))
-
XXXX_P08 (New Sites Only - AC power meter and Metering Installation Certificate (needed for as-builts only on new sites))
-
XXXX_P09_Before (Load current in Eaton rectifier cabinet before integration)
-
XXXX_P09_After (Load current in Eaton rectifier cabinet after integration)
-
XXXX_P10 (All cabinets - close up of batteries to show amp/hours rating. Take this photo through the front grill of indoor cabinets unless this has already been removed)
-
XXXX_P11 (New Sites Only - Earth resistivity label)
-
XXXX_P13 (CHORUS ONLY - Photo of AC distribution board feeding the mobile site.)
-
XXXX_P14 (CHORUS ONLY - Photo of AC breaker feeding the mobile site.)
-
XXXX_F01 (FirePro Unit installation - Utility Cabinet (where site in public land or road reserve))
-
XXXX_F02 (FirePro Unit installation - Tower (where site in public land or road reserve))
-
XXXX_F03 (Fire Stopping (Building Penetrations, Utility Cabinet, Feeder Ducts))
-
XXXX_L01 (Top Anchor)
-
XXXX_L02 (Bottom Tensioner)
-
XXXX_L03 (Tag)
-
XXXX_L04 (View looking up tower shaft with Latchway completed)
-
XXXX_C01_PrePour (Pre pour and after photo of any changes to the foundations)
-
XXXX_C02 (Before and after photo of any new steelwork or strengthening on the tower (hold down bolts, flanges, mounts, headframes, guy wires and hardware))
-
XXXX_C03 (Guy wire photo with ruler/caliper showing the actual size of the new guy wires)
-
XXXX_C04 (Tagged Anchor Points)