Information

  • Document No.

  • Project Name

  • Auditor

  • Location
  • Weather Conditions.

  • Conducted on

  • Contractors

Administration / Program

  • Do workers have current Safety/ cGMP Orientation, contractor training verification?

  • Is the Emergency Response Plan, Evacuation Plan, and Rescue procedure in place, muster point posted on job site and emergency numbers posted?

  • Are construction signs posted?

  • Is the following safety documentation located on site?

  • Job Safety Analysis

  • Procedure 12

  • Safety Data Sheets

  • Safe Plan of Action

  • Daily equipment checklist

  • Are all proper sanitary conditions met? ( eg. drinking water, wash facilities, and toilets accessible and clean?)

  • Are all personnel OSHA 10Hr trained or 30Hr for foreman / Supervisors?

  • Is there a Permit(s) issued for the task(s) being performed on the job site?

  • List all applicable permits

Housekeeping

  • Does the Job Site appear to be organized, not cluttered?

  • Are Walking/ working surfaces clear, clean, trip hazards eliminated?

  • Is the trash/ construction debris emptied daily?

  • Are the dumpsters covered?

  • Are materials stored neatly in a safe manner, no danger of falling?

  • Are measures being taken to help prevent rodents, insects and pest from infesting the work site?

PPE

  • Are hard hats, safety glasses, ANSI 3 EN 4 cut resistant gloves, ANSI II vest (as required) and safety toe footwear worn by craft and management?

  • Is there work being performed that is producing flying debris?

  • Are Face shield or goggles worn as appropriate?

  • Does the SPA reflect the use of PPE?

  • Is the work being performed exceeding 85db ?

  • Is Hearing protection being worn?

  • Is there hearing protection required signage?

  • Are respirators required to be worn?

  • Is there a respiratory program in place? Have workers been medically cleared and fit tested?

  • Are dust mask being worn?

  • Have workers filled out a "Voluntary Use of NIOSH Approved dust Masks" form?

Fire Safety and Emergency.

  • Are the proper fire extinguishers available with in 75ft of work ?

  • Is the Fire Extinguisher Inspection current?

  • Are stairwells clear of combustible or flammable materials?

  • Are the sprinkler heads & fire protection unobstructed ( sprinkler heads clear by 18'' or greater)?

  • Are flammable and combustible materials stored properly?

  • Used oily rags in a labeled metal container with lid?

  • Is there a First Aid Kit and eye wash station on job site?

  • Do workers know evacuation alarm signals and evacuation routes?

General Safety

  • Are PPE signs posted?

  • Is temporary lighting provided as needed? <br>(29 CFR 1926.56(a) table D-3)

  • Is equipment guarding in place as per manufacturers instructions?

  • Are tools and equipment inspected and in good condition prior to use?

Fall Protection

  • Is work being preformed greater than 6ft?

  • Has the Elevated work permit been completed and reviewed?

  • Is the fall calculation section completed by a competent person?

  • Is appropriate PFAS being used with SRL below 18ft or SRL/ Lanyard above 18ft?

  • Is Fall protection equipment inspected prior to use? (relief step installed)

  • Are PFAS stored correctly?

  • Is Perimeter guarding provided? ( 42in top rail and Mid rail present, toe board)

  • Are Holes/penetrations protected with secured covers labeled "HOLE" or barricaded?

Ladders/ Stairs/ Scaffolds

  • Are there ladders being used?

  • Are ladders in good operating conditions, inspected and stored properly?

  • Are Decals legible?

  • Are personnel Maintaining 3 points of contact?

  • Is a Elevated work permit in place?

  • Is the anchorage point able to support 5,000lbs?

  • Are extension ladders tied off and/or footed and secured, extended 36 in above landing?

  • Are Stairs provided where there is a change in elevation >19'' ( EU >0.5m), and secured?

  • Are Stairs greater than 4 risers all equipped with a hand rail?

  • Are the Scaffolds correct and secured, tagged correctly, inspected daily? ( check mudsills or locked wheels)

  • Are the Scaffold planks overlapping 12in where required?

  • Are there Safe access / egress for scaffold? (swing gates where required)

Welding/ Cutting / Brazing/ Spark producing

  • Is Hot work being performed?

  • List the type of Hot Work.

  • Has the hot work permit been completed and reviewed?

  • Have all combustibles been removed 35ft or covered? ( flammables removed)

  • Is torch cutting being performed?

  • Are Torches, hoses, gauges / regulators in good conditions and equipped with flash back preventers?

  • Is Shielded metal arc welding (SMAW), Gas tungsten arc welding (GTAW), or Gas metal arc welding (GMAW) being performed?

  • Are welding screens used where needed and properly secured?

  • Are Cables and welding machine inspected in accordance with manufactures instruction?

  • Are workers wearing the appropriate PPE for the task being performed? (Lens, Gloves, Sleeves)

  • Are compressed gas cylinders secured and capped when not in use?

Crane Lifting / Rigging.

  • Is there a Crane lift at the site?

  • Has the lift plan and permit been completed and reviewed with all affected personnel?

  • Are there trained signal men in "line of sight" of operator or other means of communication with operator?

  • Has the qualified rigger inspected all lifting equipment prior to use?

  • Has the crane been properly barricaded?

  • Is there a spill kit on the job site?<br>

  • Have all the areas within the swing radius been notified, with proper signage, barricaded with danger tape and evacuated?

  • Is there a road closures in place for this lift?

  • Has the road closure permit been reviewed and completed?

  • Has the road been properly sectioned off from any pedestrian and vehicle traffic?

  • Have all the above crane precautionary actions been checked off?

  • Does the crane operator have their CCO license on them?

  • Operators signature

  • Has the crane inspections been completed and documented?

  • Are tag lines being used to control the load?

Excavation

  • Is there an excavation at the job site?

  • Has the excavation permit been completed and reviewed?

  • Is the Excavation greater than 5ft?

  • Are conditions such that a confined space permit is required?

  • Are the trenches/ excavations sloped properly or shored and barricaded?

  • Adequate egress in place, ladders no more than 25ft apart?

  • If the excavation is greater than 4ft, is there a fall protection system in place?

  • Has utility location taken place? 8 feet outside the permiter of the excavation?<br>Verify report

  • Utility mark out is clear and being refreshed by the excavation contractor?

  • Are spoils, tools, materials etc. kept a minimum 2ft from the edge?

  • Is this a HAZWOPER site, Potential Source Area (PSA)?

  • Do workers have current 40hr HAZWOPER training?

  • Is the soil being tested or monitored?

  • Has a weather event occurred since initial evaluation from a competent person?

  • Has the competent person re-evaluated excavation?

  • Competent person signature.

Confined Space

  • Are there confined space entries being made at the site?

  • Has the confined space permit been completed and reviewed? <br>OR<br>Has the Standard Operating Procedure's (SOP) been reviewed?

  • Are the Confined space personnel properly trained?

  • Retrieval equipment and rescue plan in place?

  • Non-entry rescue plan?

  • Entry rescue team on standby?

  • Has the confined space attendant properly maintained the access log?

  • Atmospheric testing at 3 levels? <br>Example: Top Middle Bottom

Motorized Equipment. (Forklifts, Telehandlers, Scissor lifts, etc.)

  • Is there motorized Equipment being use?

  • Has the proper inspection been performed and documented?

  • Do the operators have the proper training for the equipment being used?

  • Are seat belts used by all operators?

  • Do the motorized vehicles have proper back up alarm?

  • Are flaggers in place where needed?

  • Is the rollover protection in place and maintained?

  • Has field modification been made without manufacturers written approval?

Electrical Safety.

  • If required, are applicable permits completed and posted?

  • Is the Proper Lockout/Tagout in place where needed?

  • Has the CDA Equipment Start Up/ Diagnostic/ Metering/ Inspection Energized Electrical Work Checklist been completed?<br>*(Superintendent should have this, if needed)*

  • Are all electrical tools and cords free of chemicals, flammables and water?

  • Are power cords protected in door openings, cords not creating a trip hazard?

  • Are cords in good condition, no cuts or repairs w/ tape?

  • Are GFCI's being used and closest to the power source?

  • Is there a 3ft clear distance around electrical panel?

  • Grounding in working order on power tools and cords?

  • Temporary electrical panels labeled and grounded?

Environmental

  • Containment for petroleum products adequate and in good condition? (free of debris, accumulation of rainwater)

  • Are drip pans being utilized for equipment such as portable welders and generators?

  • Have all proper barricades been put in place to minimize cross contamination?

  • Documentation of asbestos survey with negative results for demolition and renovation?

  • Are Storm sewers protected?

  • Is Threading Machine catch box in place?

  • Is the waste handling and disposal of hazardous waste being executed properly?

  • All containers labeled? (HAZCOM)

  • Are there chemicals at the job site?

  • Are personnel trained in the chemicals they are handling?

  • Are the SDS provided at job site? ( point of use )

  • Is there proper ventilation in place for stored chemicals?

  • Are the Concrete truck washout procedure being followed?

  • Dust generation (due to Silica) minimized / controlled?

  • Is the erosion and sedimentation control at site in place and being used effectively? (silt fence, tarps, mulching)

  • The erosion and sedimentation control inspections are being completed and logged?

Notes

Corrective Actions

stakeholders

  • PM or CM

  • Auditor.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.