Information
QC Inspection Card PT Slab Bldg 3 & 5
-
Mix #
-
Contractor
-
Date
-
Scheduled Start
-
Estimated CY
A-Verify Layout
-
Add media
-
CFC Reviewed
-
Sub Reviewed
B-Surface Preparation
-
Add media
-
CFC Reviewed
-
Sub Reviewed
C-Forms
Alignment
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Stability
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Form Surfaces
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Tub Boxes
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Safe Work Area
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Form Treatment
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Cleanliness
-
Add media
-
CFC Reviewed
-
Sub Reviewed
D-Reinforcement
Size
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Location
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Spacing
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Splices
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Tie Wires
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Chairs & Spacers
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Quantity
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Bends
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Detail 3-S401
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Detail 11-S401
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Detail 14-S401
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Keynote #4
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Keynote #5
-
Add media
-
CFC Reviewed
-
Sub Reviewed
E-Embedments
3/4" Anchor Bolts @ 32" oc
-
Add media
-
CFC Reviewed
-
Sub Reviewed
F-Tendons
Quantities
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Size
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Spacing
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Chair Height (2")
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Transitions Around Openings (3")
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Clear Cover @ Dead End
-
Add media
-
CFC Reviewed
-
Sub Reviewed
G-Concrete Placement
Top of Form Elevation
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Slab Depth
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Slope @ Porch
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Slope @ Garage
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Air is 4.5%-7.5%
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Slump is 3"-5"
-
Add media
-
CFC Reviewed
-
Sub Reviewed
H-Insulation
Plumbing
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Porches Only
-
Add media
-
CFC Reviewed
-
Sub Reviewed
I-Testing
Mix Design
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Cylinders
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Slump Test
-
Add media
-
CFC Reviewed
-
Sub Reviewed
1-Hold
-
Add media
-
CFC Reviewed
-
Sub Reviewed
2-28 Day
-
Add media
-
CFC Reviewed
-
Sub Reviewed
1-7 Day
-
Add media
-
CFC Reviewed
-
Sub Reviewed
1-5 Day
-
Add media
-
CFC Reviewed
-
Sub Reviewed
G-Inspections
-
Add media
-
Anchor Engineering
-
Add media
-
Ground Engineering
K-Other Items
Conduit for Islands @ Kitchens
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Fire Line
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Domestic Line
-
Add media
-
CFC Reviewed
-
Sub Reviewed
RFI 006 Plumbing Slumps
-
Add media
-
CFC Reviewed
-
Sub Reviewed
RFI 032 Cable & Telephone Entry
-
Add media
-
CFC Reviewed
-
Sub Reviewed
RFI 035 Slopes @ Corridors
-
Add media
-
CFC Reviewed
-
Sub Reviewed
RFI 042 Garage Step Detail
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Broom Finish @ Balcony & Porches
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Speed Dowels
-
Add media
-
CFC Reviewed
-
Sub Reviewed
Pilaster FF = 100
-
Add media
-
CFC Reviewed
-
Sub Reviewed
-
Deficiencies/Remarks:
-
Contractor Signature
-
Date
-
CFC Signature
-
Date