Title Page

  • Development Application No.

  • Site Address:

  • Building Classification:

  • Development Description:

  • Assessment Date

  • Assessed by:

  • Add signature

  • Builder:

SITE PLAN

  • Total Floor Area:

  • North Point

  • Distance from Boundaries

  • Retaining Walls

  • Firewalls/Separation

  • Gutters/Downpipes (12m Max Spacing)

Preliminaries

  • Minimum 2 Copies of plans provided

  • Building Indemnity Insurance provided (Development over $12,000)

  • Construction Industry Training Levy Paid (Development Over $15,000)

  • Stormwater Management Details Provided

  • Glazing compliant with AS1288 & AS2047

  • Wall Construction

  • Easements On Site

Footings & Foundations

  • Cut/Fill details provided (AS 2870)

  • Soil Classification:

  • Reinforcement

  • Footing/Slab Design

  • Termite Protection Certification (AS 3600)

  • Supporting Engineering Calculations

Masonry

  • Masonry Control Joints (BCA 3.3.1.8)

  • Weep Holes (AS 3.3.4.3)

  • D.P.C. (AS 3.3.4)

  • Brick Ties, 600 x 600 C/C, 300 x 600 around openings (BCA 3.3.3.2)

  • Masonry Lintels

Wall Frame Timber

  • TImber Durability

  • Wall Studs

  • Top/Bottom Plates

  • Jamb Studs

  • Studs under concentrated loads

  • Lintels

  • Support Beams

  • Bracing (Wind Direction 1)

  • Bracing (Wind Direction 2)

  • Tie Downs

  • Stair Construction

Roof Frame Timber

  • Wind Speed

  • Roof Frame Layout (Truss/Conventional Arrangement)

  • Roof Type

  • Roof Pitch:

  • Rafter/Roof Truss Tie Downs

  • Roof Batten Tie Downs

  • Roof Bracing

  • Top Chord Restraint

  • Bottom Chord Restraint

Steel Frame

  • Supporting Engineering Documentation Provided?

  • Has a Regulation 88 Certificate been provided?

  • Has the correct windspeed been selected?

  • Has the correct Importance Level been selected?

General

  • Attachment to existing dwelling (Rafter Strengthening Brackets)

  • Tie Downs to Existing Roof (are additional provided)

  • New Crossover Permit Issued

Additional Notes

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.