Information
-
Document No.
-
Address (Mandatory Requirement)
-
Auditor
INSTALLATION DETAILS
-
Date and Time:
-
Name of Occupant:
-
Address:
-
Installation Engineer(s)
PLEASE SELECT FROM ONE OF THE FOLLOWING AUDITS
-
Multiple audits can be completed if required.
IMPORTANT NOTICE:
It is a mandatory requirement that the Occupant/Home Owner and the Assessor sign this report upon completed. -
Electrical QA Audit
ELECTRICAL QA AUDIT
-
Has RCD Protection been provided to the works/circuit being worked on?
-
Insert Image
-
WARNING - DO NOT PROCEED UNTIL WORKS HAVE BEEN CARRIED OUT TO A SATISFACTORY STANDARD
-
PLEASE ENSURE BY HAVING NO RCD PROTECTION THE INSTALLATION IS STILL COMPLIANT TO CURRENT WIRING REGULATIONS
-
Type of Main Incoming Electrical Supply?
-
NOTE:
BOTH GAS AND WATER EARTHS MUST BE PRESENT.
MINIMUM CABLE CSA IS 6.0mm
MAIN EARTH TO FUSE BOARD MUST HAVE A CSA OF 10.0mm
Key: CSA - Cross Sectional Area -
NOTE:
BOTH GAS AND WATER EARTHS MUST BE PRESENT.
MINIMUM CABLE CSA IS 10.0mm
MAIN EARTH TO FUSE BOARD MUST HAVE A CSA OF 16.0mm
Key: CSA - Cross Sectional Area -
THE WHOLE PROPERTY MUST HAVE RCD PROTECTION NO EXCEPTIONS
NOTE:
BOTH GAS AND WATER EARTHS MUST BE PRESENT.
MINIMUM CABLE CSA IS 10.0mm
MAIN EARTH TO FUSE BOARD MUST HAVE A CSA OF 16.0mm
Key: CSA - Cross Sectional Area -
Main Water Bond Visible?
-
Is the clamp within 300mm of the services?
-
Is the clamp tight and secure?
-
Select CSA of the cable
-
WARNING - NOT COMPLIANT UPGRADE REQUIRED
-
WARNING - NOT COMPLIANT UPGRADE REQUIRED
-
COMPLIANT - HOWEVER UPGRADE RECOMMENDED TO BRING UPTO 17th EDITION WIRING REGULATIONS
-
COMPLIANT
-
THE EARTH BOND MUST BE PRESENT TO COMPLY WITH 17th EDITION WIRING REGULATIONS.
PLEASE MAKE ARRANGEMENTS WITH VALLEY SERVICES HEAD OFFICES FOR THESE WORKS TO BE COMPLETED. -
Main Gas Bond Visible?
-
Is the clamp within 300mm of the services?
-
Is the clamp tight and secure?
-
Select CSA of the cable
-
WARNING - NOT COMPLIANT UPGRADE REQUIRED
-
WARNING - NOT COMPLIANT UPGRADE REQUIRED
-
COMPLIANT - HOWEVER UPGRADE RECOMMENDED TO BRING UPTO 17th EDITION WIRING REGULATIONS
-
COMPLIANT
-
THE EARTH BOND MUST BE PRESENT TO COMPLY WITH 17th EDITION WIRING REGULATIONS.
PLEASE MAKE ARRANGEMENTS WITH VALLEY SERVICES HEAD OFFICES FOR THESE WORKS TO BE COMPLETED. -
Installation of fused spur
-
IMPORTANT NOTICE - please check and confirm the fuse size in accordance with manufacture recommendations.
-
Fuse Size:
-
Refer to manufacturers requirements to confirm 5 amp is adequate.
-
IMPORTANT NOTICE - Incorrect fuse size, please install the correct size.
-
Insert Image
-
Programmer installed satisfactory?
-
Insert Image
-
WARNING - DO NOT PROCEED UNTIL WORKS HAVE BEEN CARRIED OUT TO A SATISFACTORY STANDARD
-
Room thermostat satisfactory?
-
Insert Image
-
Make:
-
Model:
-
Serial Number:
-
WARNING - DO NOT PROCEED UNTIL WORKS HAVE BEEN CARRIED OUT TO A SATISFACTORY STANDARD
-
Comments in relation to any item in this section.
-
Insert Ze (Ohms):
-
Insert PFC (kA):
-
RCD X1 (mS):
-
RCD X5 (mS):
SIGN OFF FORMS
-
Image of Test Certificate:
-
Image of Customer Satisfaction Form:
-
Image of Occupant Sign off Form:
-
Are there any Customer Care Issues?
CUSTOMER CARE (To be completed in all cases)
-
Property damage?
-
Damage to Property?
Defect
-
Insert Image:
-
Insert Comment:
-
Dust sheets used?
-
Installed in a neat and tidy manner?
-
Redundant materials removed?
-
Customer informed of works completed?
-
Customer advised of use of controls?
-
System flushed correctly?
-
Comments in relation to any item in this section.
-
Are any Follow Ups Required?
FOLLOW UP REQUIRED?
-
Remedial's required?
-
NO ACTION REQUIRED
-
Description of remedial works:
-
Insert Image of remedial works required.
-
Have the issues been notified to head office?
-
Who was this reported to?
-
Method of notification:
-
Date and Time Notified:
-
NOTIFY HEAD OFFICE AND REPORT
-
Do you require the occupant to sign this report?
DECLARATION - TO BE COMPLETED BY THE CUSTOMER
-
Have all works been completed to a satisfactory level?<br><br>
-
Please give details of where you feel you have not received a quality service.
-
Would you recommend us to others?
-
We are very sorry to hear this and apologise in advance for the issues you are not happy with.
-
Excellent.... Did you know you can earn money for referring to friends and family.
Please ask the assessor for a leaflet to pass around. -
I agree that by signing this report I am happy that the inspection and works have been carried out to a satisfactory standard.
In addition to this, I can confirm no damage has been made during the course of these works. -
Customer Signature - Print & Sign
-
Date:
-
Would you please be kind enough to write a few words for our testimonial page on our website?
-
Customer Testimonial:
-
Do you require the assessor to sign the report?
SIGN OFF - TO BE COMPLETED BY THE ASSESOR
-
I the assessor have given a true and accurate account of the inspection and can confirm the installation is satisfactory and the customer is happy with the services received by our companies.
-
Assessor - Print & Sign
-
Date:
-
PLEASE EMAIL THIS TO donna.gilbert@corsan.co.uk AT HEAD OFFICE.
THIS REPORT FORMS PART OF THE QA AND HEALTH & SAFETY COMPLIANCE.