Project nr.
-
Client
-
Document No.
-
Date:
Mechanical
-
Check if system is in accordance with P&ID (incl Tag Numbering)<br>If not correct fill in the remark<br>a) change in workshop<br>b) Markup P&ID
-
system is not inaccordance with P&ID therefore corrective action is
-
Check if system is in accordance with Piping & Skid arrangement drawings (For example Dimension & Geometrical inspection)<br>If not correct <br>a) Change in workhop<br>b) Mark up Drawing<br>Write down all important dimensions
-
System is not inaccordance with piping & skid arrangement drawings therefore corrective action is
-
Check if build-up actuator is in accordance with P&ID<br>if not correct <br>a) change in workshop<br>b) markup drawing<br>
-
build up actuator is not inaccordance with P&ID therefor corrective action is
-
Check if all flanges are completely filled with stud bolts washers and if all stud bolts are tightened.<br>Check also correct size of the gaskets.
-
Check equipment accesibility & operability
-
Check flow directions of equipment.
-
Check equipment design data on nameplates.
-
Check all ballvalves if they can be opened and closed in a normal way.
-
Check instrumentation for correct ranges Correct hookup and damages
-
Check insulation for thickness, silicon sealing, finishing touch, heat tracing and damages.
-
Check loose deliveries (e.g. Shimplates, anchor bolts, counter flanges, stud bolts, gaskets, vent piping etc)
Coating
-
Check coating thickness
-
Check colors op piping, skids and valves.
-
Check if the coating is firm attached
-
Check general condition of coating (damages, dirt in or under the coating and droplets)
Electrical
-
Check if all cables are connected according drawing<br>if not correct <br>a) change in workshop<br>b) markup drawing<br>
-
Cables are not connected according drawing therefore corrective action is
-
Check if all conduit openings are plugged
-
Check if Conduit is sufficient supported
-
Check if all electrical items are equipped with a proper cable gland
-
Check cable gland sizes
-
Check accessibility & protection degree of junction boxes
-
Check if cables are firm fixed in the cable glands
-
Check if not-armored cables are protected with Anaconda-hose (for example at the Hadro level gauges)
-
Check cable numbers
Quality Documents
-
Are all activities as per MITP done, checked and signed
Workshop construction manual
-
WPS & PQR
-
Material Certificates
-
Hydro-test reports
-
NDT reports
-
X-ray locations
-
Paint Certificate
-
Leak test certificate
-
Component material certificates
-
Component explosion certificates (if applicable)
-
Component calibration certificates (if applicable)
-
Certificate of conformity
-
Write down all heat no of the valves, transmitters , level gauges etc
Component
-
Merk component
-
Heatnummer
Packing
-
Internal cleanliness and protective coating
-
External cleanliness and protective coating
-
Protective covers for machined and vulnerable surfaces (flanges, threads, etc)
-
Verification of packinglist
-
Verification of package marking
-
Shipping documents attached (packing list C of C, EC documents etc)
General Project Related Inspections
-
Are nameplates installed on the skids
-
Check earthing bosses for removed paint and attached grease
-
Check if ll counter flanges/spec blinds are mounted on the skid including gaskets, bolts nuts and washers
-
Open ends of stand pipes closed and or checked for rough ends
-
Check if locking devices are attached on the ball valves
-
Check if instrument vent drain valves are plugged with a blind plug
-
Check if there are blind plugs in the spare thermowell and on other needed areas
-
Check if rough edges of the cable trays are protected with a protection strip
-
Check if the equalizing line of the automatic drain is attached in the system
-
Check if SS piping is clear of rust stance
-
Check tag numbering of the junction boxes
General Remarks
-
Check if all not insulated parts are in the final colour.
-
Registered the serial numbers of the big valves, actuators, diff.pressure gauge/switch , level switch, relief valves, thermocouples, temp and pressure gauges.
-
Are the Core numbers correctly mounted on the cables in the junction boxes?
-
Are the ball valves/actuators in the correct "open/close" position?
-
Are the seats in ball-valves resistant to the required pressure and temperature?
-
Are earth cables connected between junction boxes & Door and between junction box & skid frame
-
Are blind plugs mounted in the vent connections of the manifolds.
-
Are the specticle blinds/restriction orifices mounted in the system. And are these correctly mounted in the system.
-
Are all valves in the closed position for transport.
-
Are the tracing stickers attached on the system (if applicable)
-
Are the thermal relief valves set at the design pressure of the system.
Signature
-
Petrogas inspector Ronald Hundscheidt