Information
-
Building
- TTC
- Construction
- Adwick
- Main Building: Block A
- Main Building: Block B
- Main Building: Block C
-
Door Number
-
Inspection Date
-
Condition of Door and Door Frame
-
Priority
Unique Fire Door Number, and Classification.
-
Has the fire door got certification references - scheme label?
-
What is the door type (single, double or one-and-half doors)?
- Single
- Double
- Door and a Half
-
What is the classification of the fire door
Door Leaf(s)
-
Is the door leaf free from damage, including dents, cracking, and holes?
-
Are door leaf edges / lippings in good condition? (No splits / cracks etc).
-
Does the door leaf sit tight against the rebate jamb / door stop?
Door Frame
-
Is the door frame free of damage?
-
Rebate jamb / doorstop width (Millimetres)
-
Is the doorframe securely attached to the surrounding structure?
Door Hinges
-
Is there a minimum of 3 hinges with all the screws fitted?
-
Fixings - screws tightly fixed
-
Are the hinges free of metal fragments and oil leakage?
-
CE Mark?
Glazing
-
Type of Glass
-
If NOT Georgian wired glass, is glass etched stating test standards, manufacturer<br>and trade name?<br>
-
Is the glass free from cracks or damage?
-
Is the glass loose? There should be no lose pins or screws.
-
Are the glazing beads in good condition? (No damage, splits, cracks, etc.)
Door Seals
-
Are intumescent strips/cold smoke seals in place?
-
Are the strips/seals continuous around the door leaf or door frame?
-
Are the strips/seals well attached inside the groove in the door leaf or frame?
-
Are brush or fin type seals free from damage?
Threshold Gap
-
Is there a consistent gap under the door that allows it to swing without touching the floor covering?
-
Is the door to floor covering gap consistently 10mm (3mm if smoke seals are fitted) or less when the door is closed?
-
If the door leaf is fitted with a threshold seal, does the seal make contact with the floor covering when the door is closed?
Door Closers
-
Is a door closer fitted?
-
Is the closer free from damage and not leaking?
-
Is the closer securely attached to the door and the frame?
-
Does the door close from any angle, and overcome the latch?
-
If hung in pairs, do doors close in line if both are opened and released together?
-
If hold open device is used, is it electronically released?
- Yes
- No
- N/A
Door Latch
-
Is door handle securely attached and operating well?
-
Does the latch hold the door firmly in the frame without rattling?
Kick Plate / Finger Plate in Good Condition
-
Is the kick plate secure and in good condition?
-
Is finger plate / D pull handle secure and in good condition?
Fire Door Signange
-
Fire Door - Keep Shut / Fire Door - Keep Locked
Air Transfer Grille
-
If air transfer grille is fitted, is it to BS 476: Part 22 standard?
Other Issues Observed
-
undefined
Untitled Page
-
Add signature