Title Page

  • Site conducted

  • Conducted on

  • Prepared by

  • Location
  • Client's Name

  • Client's Address

  • Premises
  • Certificate Number/Reference

  • Engineers Signature

  • Client's Signature

Details of the system

  • Grade of intruder alarm

  • Monitoring Type

  • Panel Type

System Design

  • Record any changes

Schedule of items checked

System Design

  • Check that the system has been installed and configured in accordance with the system design proposal (any deviations agreed in writing with the customer)

  • Check the system complies with current industry standards

Interconnections and Cabling

  • Check that all interconnections are clearly labelled at the Control & Indicating Equipment, power supply units, expanders, remote key pads and junction boxes

  • Log resistance of detection interconnections or check continuity of bus wired interconnections

  • Record resistance in ohms

  • Check every detector for correct operation through to the Cause & Indicating Equipment

  • Check that all batteries in Cause & Indicating Equipment and/or Power Supplies are marked with the date of installation

Device Operation

  • All SAB operate on battery voltage

  • Record the voltage at the SAB

  • The SAB operates when hold off voltage is removed

  • Operation of all tamper devices

  • Check the area or volume of coverage of movement/vibration detectors including alignment of active beam detectors and any anti-masking or range reduction facilities (as appropriate)

  • Check the operation of the entry/exit route

  • What is the entry time

  • What is exit time

  • When the system is set, check it alarms correctly when activated

  • Power Supplies
  • Mains supply is from an unswitched fused connection unit

  • The supply fuse rating is 3a

  • The mains supply can not be accidentally or intentionally switched off

  • Cause & Indicating Equipment have had their current draw taken

  • Current draw of Cause & Indicating Equipment in alarm

  • Current draw of Cause & Indicating Equipment in quiescent

  • Power Supplies are fitted

  • Current draw of Power Supply Equipment in alarm

  • Current draw of Power Supply Equipment in quiescent

  • The system operates correctly on battery supply only

  • All voltages are within the acceptable limits when the system is on battery standby

  • Standby duration of the battery is suitable for the grading of the system

Alarm Transmission System

  • System is monitored

  • All signal paths have been tested and reported correctly to the Alarm Receiving Centre

  • Signal paths operate correctly when the system is alarmed

Hand Over

  • Client has been shown how to use the system correctly

  • The limits of detection have been shown to Client

  • All documentation has been completed correctly

  • Number of fobs issued to client

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.